Maintenance procedure:  

-

 

Stop the compressor, close the pressure conduit valve. 

-

 

Lower  the  overpressure  in  the  screw  assembly  body  till  reaches  the  atmospheric  pressure  (to 
lower the overpressure inside the screw assembly body wait about 5 minutes after switching off 
the compressor,  

-

 

Safeguard  the  compressor  from  restarting  by  an  unauthorized  person,  e.g.  by  cutting  power 
supply off.  

-

 

Dismantle the radiator. 

-

 

Clean and remove impurities. 

-

 

Reassemble all disassembled components. 

-

 

Fill (top up) the compressor with oil. 

-

 

Carry out a operating test for approx. 3 to 5 minutes. 

-

 

Stop the compressor, check the oil level and top up if necessary.  

 

7.3.8. 

. Electric motor 

When the compressor is running, check the motor operation by paying attention to the following: 

-

 

Operating noise, 

-

 

Excessive vibration, 

-

 

Excessive current consumption 

 protection activation in the electrical cabinet, 

-

 

The condition of the fixing screws, 

-

 

A degree of fouling.

 

The motor (compressor) should be stopped immediately in case of: 

-

 

Overheating,  

-

 

Smoke or burningsmell,  

-

 

Excessive vibration, 

-

 

Bearing noise. 

 

The machine can be restarted after removing the cause of any failures

 

 

Periodic motor inspections: 

The motor inspection should be performed at least once per 2 years. 
The  inspection  should  be  performed  by  the  in-house  personnel  or  properly  qualified  personnel 
from specialized companies. 
Any  repairs  or  special  inspections  should  be  performed  by  the  specialised  workshop  or  the 
manufacturer service. 
 
Replacement  or  lubrication  of  the  motor  bearings  must  be  performed  in  accordance  with  the 

manufacturer’s  recommendations.  The  permissible  hours  of  the  bearing  operation  to  the 

replacement or lubrication are presented in the table below. When any symptoms indicating the 
bearing  damage  occur  (unusual  noise  or  increased  temperatures),  contact  the  service 
immediately. 

 

 

 
 
 
 
 
 
 
 
 
 

7.3.9 

Safety valve 

The safety valves fulfil an important  function in pressure equipment  and systems. They require 
particularly  careful  and  professional  service.  Any  operational  shortcomings  may  damage  the 

Hours of operation until the performance of service operations 

Motor power 

Bearing type 

Hours of operation 

Operations 

3-22 kW  Maintenance-free 

40000 h  Replacement 

30-55 kW  Maintenance-free 

20000 h  Replacement 

75-90 kW  Requiring maintenance 

4000 h  Lubrication 

110-200 kW  Requiring maintenance 

3000 h  Lubrication 

Содержание KOMPBERG ZX55

Страница 1: ...OPERATING AND MAINTENANCE MANUAL Oil free screw compressor KOMPBERG ZX55...

Страница 2: ...the choice you have made and the cooperation you started with us Our compressors are machines of top quality which is the guarantee for a long years and reliable performance Our sales and service sta...

Страница 3: ...w compressor KOMPBERG ZX55 operating description 12 Technological diagram 14 6 Start up 17 6 1 Start up preparation 17 6 2 Restart after longer downtime 18 7 Maintenance 19 7 1 General requirements 19...

Страница 4: ...e and maintenance of the compressor and control system Technical documentation of the electrical part It includes the data necessary to perform correct connections and repairs of the electrical equipm...

Страница 5: ...gases it is required to obtain the manufacturer s consent The above consent must be in written form The compressor must not be used for any other purposes that are non compliant with its intended use...

Страница 6: ...referred to as the Warrantor provides the warranty for the products sold ensures correct operation of the offered products provided that they are used in accordance with their intended use and operat...

Страница 7: ...such a way that they do not place pressure on it If the transport harness is fastened and secured incorrectly the machine may get damaged The compressor must be transported only with a forklift Fasten...

Страница 8: ...rohibited to service the safety valves or to change their settings Do not change settings of the pressure switches above the value given in the identification plate or in the Operating and Maintenance...

Страница 9: ...d 130dB Equivalent acoustic pressure level corrected by A characteristic does not exceed 85 db A AUTOMATIC MACHINERY MAY START RISK OF SCALDING RISK OF ELECTRIC SHOCK Type KOMPBERG ZX55 Overpressure M...

Страница 10: ...ntilation is insufficient windows openings in a wall etc in the compressor room air exchange should be provided by fans To ensure correct heat extraction the fans should have total capacity about 15 t...

Страница 11: ...electrical connections Use the required safety measures in accordance with the suitable regulations Calculate the power cable cross sectional area and fuse sizes according to the local regulations and...

Страница 12: ...5 Screw compressor operating description 5 1 Screw compressor KOMPBERG ZX55 operating description General view of an oil free screw compressor KOMPBERG ZX55...

Страница 13: ...and then flows to the oil filter assembly 18 The oil filter set is fitted with a thermostat 17 which depending on the oil temperature directs the oil directly through the oil filter 18 to the manifol...

Страница 14: ...25 Solenoid valve with time system 8 Venturi nozzle 26 Air filter pollution sensor 9 2nd stage cooler 27 Temperature sensor 10 Check valve 28 Safety valve 11 2nd stage unloading 29 Pressure sensor 12...

Страница 15: ...correctness of the lubrication and sealing processes Therefore these spaces must be ventilated This is accomplished by means of a flexible hose and an air filter located at the tunnel of the fan In th...

Страница 16: ...itched off and on the compressor can be started by unlatching the EMERGENCY STOP STOP AWARYJNY button and pressing the START button The compressor is provided with an additional protective function wh...

Страница 17: ...ons are in place do not connect the compressor to a power source of different voltage than that specified in the Operating and Maintenance Manual Connect the phase conductors so that the rotation dire...

Страница 18: ...t switches to the stand by mode and starts again after its drop Incorrect rotation direction of the screw block rotors for more than 5 seconds will damage the screw compressor Proper direction of scre...

Страница 19: ...e components Take appropriate safety measures against toxic vapours from cleaning agents Biodegradable detergents should be used The workplace must be kept absolutely clean when maintenance work is ca...

Страница 20: ...he filter is recommended check the condition of the elastic coupling clean the air and oil cooler ribs if necessary 7 2 4 Warranty and post warranty checks every 2000 work hours or after 1 year change...

Страница 21: ...ot apply force avoid damaging the cartridge Clean contact surfaces of gaskets Purging purge the external surface of the cartridge with dry compressed air at the pressure up to 0 5 MPa askew from the i...

Страница 22: ...ner to replace the filter Caution hot oil Rub some oil onto the gasket of the new filter before screwing it in Fill the new filter held vertically with the same type of oil as that in the separator ta...

Страница 23: ...lves in the radiator see the controller operating instructions Unscrew the compressor crankcase ventilation hose on the compressor stage body see Fig 11 Place a suitable container and carefully unscre...

Страница 24: ...ridges should be disposed of according to the valid legislation on handling wastes waste code 16 01 07 7 3 7 Oil cooler exchanger interstage final air The safety of the screw compressor requires regul...

Страница 25: ...restarted after removing the cause of any failures Periodic motor inspections The motor inspection should be performed at least once per 2 years The inspection should be performed by the in house pers...

Страница 26: ...ed at the pressure equal at least 50 of the operating pressure The valves delivered require no special maintenance They should only be periodically every 1000 hours blown by pulling the handle of the...

Страница 27: ...oil temperature too high the compressor does not start ambient temperature 40 C ensure adequate ventilation in the room contaminated cooler clean the cooler exchanger operating pressure above the set...

Страница 28: ...he nameplate adjust the correct settings in the controller screw seizure call service activation of safety valve safety valve damaged replace with a new one with appropriate setting or call service wr...

Страница 29: ......

Страница 30: ...ber Quantity 1 Air filter BL 480045 BL 480046 1 2 Compressed air filter cartridge Element for F 24 GW 24 G 1 3 Oil filter B 480001 1 4 Coupling insert BS 480165 1 5 Oil l 480069 40 6 Thermostat cartri...

Отзывы: