background image

 

 

 

Solar Module 50

 

 

Operating Manual  
 

 

Содержание Solar module 50

Страница 1: ...Solar Module 50 Operating Manual...

Страница 2: ...4 4 Structure of the solar module 4 5 Safety instructions 5 6 Assembly and commissioning 6 6 1 Assembly 6 6 2 Positioning the solar module 6 6 3 Hydraulic connection 10 6 4 Electrical connection 10 6...

Страница 3: ...ase note the warnings given in champter 3 Improper handling or operation may lead to damage of the system 1 1 Use The solar module 50 enables the buffer tank to be loaded depending on the temperature...

Страница 4: ...technical personnel should carry out the assembly maintenance and cleaning of the shift layer module Unauthorised modifications or changes are not permitted on the system for safety reasons and inevi...

Страница 5: ...7 NORM M7700 Solar heating and solar thermal plants Solar energy Terms with definitions DIN 18380 NORM M7701 Central heating systems and process water systems Solar plants Approximation procedure for...

Страница 6: ...he erection and installation must be done by an approved technical agency This agency also takes over the responsibility for correct installation and commissioning A dry frost free room that provides...

Страница 7: ...1 As given in the Drilling jig enclosed drill the boreholes marked with the 10 mm dia drill bit at least 8 cm deep 2 Next insert the dowels into the borehole and screw in the hanger bolts into the br...

Страница 8: ...8 Drilling jig for wall mounting...

Страница 9: ...material in 3 steps as follows Step 1 Figure above Step 2 Figure above Mount and tighten the 3 threaded rods and the 3 corrugated pipe hoses including the gaskets at the relevant connecting points on...

Страница 10: ...orces on components and connections that have already been pre mounted must be avoided at all costs In addition all flat seal connections must be checked for the right tightening torque of the union n...

Страница 11: ...ly de aerated Flow noises during operation of the buffer loading pump indicate that there is still some air in the plant which needs to be discharged via the pump and the manual bleeding or venting de...

Страница 12: ...the direction opposite to the flow 12 You can now switch the pump off and remove the connections of the filling pump from the KFE valves A and B 13 The solar circuit is now filled up completely and r...

Страница 13: ...al thread E Buffer inflow hot ball valve G1 external thread F Solar inflow G1 external thread G Solar return flow G1 external thread H Connection to the expansion tank G3 4 external thread Maximum ope...

Страница 14: ...14 7 1 Design...

Страница 15: ...15 7 2 Pump characteristics...

Страница 16: ...s a warranty of 2 years from the date of delivery for the products and components supplied Unauthorised modifications or changes are not permitted on the system for safety reasons and inevitably lead...

Страница 17: ...17 Notes...

Страница 18: ...18 Notes...

Страница 19: ...19...

Страница 20: ...Rev 1 05 12...