Installation

INSTALLATION

GENERAL INSTRUCTIONS

Assembly

The system must be installed by specialist personnel. Use 

only the assembly material supplied with the solar collec-

tor. The supporting framework and all masonry or brick-

work fixing points must be checked by a person expert in 

static loading, and must be suitable for the nature of the 

installation site.

Static load

The solar collector must only be installed on roofs or frames 

that are strong enough to support its weight. The strength 

of the roof or frame must be verified on site by a person ex-

pert in static loading before the solar collector is installed. 

During this process, it is important to verify the suitability 

of the supporting frame to hold the screw fasteners that fix 

the solar collector in place. An expert in static loading must 

verify that the entire frame complies with relevant stand-

ards, especially in areas liable to snow and areas exposed 

to high winds. Conditions (gusts of wind, formation of wind 

vortices, etc.) at the point where the solar collector is to 

be installed must be carefully considered since these can 

increase the loads on the supporting structure.

Lightning protection

The metal piping of the solar heating circuit must be con-

nected to the main potential compensation bar by a (yel-

low-green) copper wire (H07 V-U or R) of at least 16 mm

2

. If 

a lightning conductor system is already installed, the solar 

collectors may be connected to the existing system. Alter-

natively, the solar collector piping may be connected to 

ground via a ground wire sunk into the earth. Ground wires 

must be sunk outside the house. The ground wire must be 

connected to the potential compensation bar through a 

wire of the same diameter.

Water connections

The solar collectors must be connected in series using the 

fittings and seal rings provided. If flexible hoses are not 

used to connect up the ends of solar collector lines, we 

recommend that you fit devices in the connecting pipes 

to permit thermal expansion (U-type expansion joints, sec-

tions of flexible hose or dedicated expansion joints). Pro-

vided adequate expansion joints are used, up to 6 solar 

collectors may be connected in series. Make sure that the 

seal rings are correctly positioned in their seats. When 

tightening a fitting with a pipe wrench or spanner, always 

hold the opposite fitting steady with a second tool to avoid 

damaging the absorber.

 

b

All pipes in the water circuit must be insulated in con-

formity to relevant standards. Lagging and insulation 

must be protected against damage by the weather 

and birds and animals.

Angle of collectors / General

Solar collectors are designed to be installed at angles of 

between 15° (minimum) and 75° (maximum). Make sure 

that the bleed and vent valves of the collectors remain 

open while the collectors are being installed. Take care 

to protect all fittings, connections, bleed and vent valves 

against dirt and dust etc. In installations which serve pri-

marily to produce domestic hot water in the summer, install 

the collectors facing from east to west at an angle of be-

tween 20 and 60°. The ideal orientation is southwards, at 

an angle equal to the latitude of the location minus 10°. If 

the system sustains the greatest thermal load in the winter 

(as in systems that combine domestic hot water production 

with central heating), install the collectors facing south (or 

south-east or south-west) at an angle greater than 35°. The 

ideal orientation is southwards, at an angle equal to the 

latitude of the location plus 10°.

 

b

Work near uncovered and live electrical wires, with 

which it is possible to come into contact, is only per-

mitted under the following conditions: wires must be 

free from voltage for the entire duration of the work; 

parts remaining live must be covered or accidental 

contact prevented; the following minimum safety dis-

tances must be respected: 1m (for voltages of up 

to 1000 Volts), 3m (for voltages from 1000 to 11000 

Volts), 4m (for voltages from 11000 to 22000 Volts), 

5m (for voltages from 22000 to 38000 Volts), >5m 

(if the voltage is not known). Contact with open, live 

electrical wires may lead to electrocution and may 

even be fatal.

 

b

Always wear safety goggles when drilling. Always 

wear safety shoes, cut-proof protective gloves and a 

safety helmet when performing installation work.

 

b

Before beginning installation work on roofs, install the 

necessary fall prevention and fall arrest devices and 

ensure that all applicable safety standards are ap-

plied. Use only tools and materials that conform to 

the safety standards that are applicable in the place 

of work.

 

b

Only wear overalls that have a safety harness (with a 

suitable safety or fall-arrest belt, ropes or slings, fall 

dampers or dissipaters). In the absence of adequate 

fall prevention and security devices, failure to use a 

proper safety harness may lead to falls from great 

heights with serious or even fatal consequences.

 

b

The use of ladders leaned against walls can lead to 

serious falls if the ladder slips, slides of falls. When 

using ladders, always ensure that they are stable, 

and that suitable ladder stops are present. If possible 

secure the ladder with hooks. Make sure that there 

are no live electrical wires near the ladder.

Содержание SCF-20N

Страница 1: ...SOLAR COLLECTOR SCF 20N INSTALLATION MANUAL SOLAR ...

Страница 2: ...imals caused by improper installation adjustment maintenance or use Range MODEL CODE SCF 20N 20050326 SCF 20N pack of 2 20050328 SCF 20N pack of 7 20050329 RANGE Contents CONTENTS The following symbols are used in this manual b b CAUTION Identifies actions that require caution and adequate preparation a a STOP Identifies actions that you MUST NOT do This manual Code Rev comprises pages System layo...

Страница 3: ...ax glycol concentration Heat transfer fluid water propylene glycol Data plate Serial number plate CODICE 20038360 FABBRICATO IN ITALIA DESCRIZIONE CP20TSA S N COLLETTORE SOLARE PIANO DIMENSIONI 1856X1087X90 mm SUPERFICIE LORDA 2 02 m2 TEMPERATURA DI STAGNAZIONE 198 C SUPERFICIE DI APERTURA 1 81 m2 CONTENUTO LIQUIDO 1 5 l SUPERFICIE ASSORBITORE 1 77 m2 PESO A VUOTO 30 kg LIQUIDO TERMOVETTORE ACQUA ...

Страница 4: ... 03 0 04 0 05 0 06 0 07 0 08 Tm m2 K W Optical efficien cy of absorber ηο Thermal dispersion factor of absorber a1 W m2 K a2 W m2 K2 0 764 4 33 0 0069 Tested according to EN 12975 referred to a 33 3 wa ter glycol mix flow rate of 75 l h and irradiation G 800W m2 Tm Coll _inlet _temp Coll _outlet_temp 2 T m Tm T_ambient G WIND AND SNOW LOADS ON COLLECTORS Installation height above ground Wind speed...

Страница 5: ...ass compression stop ends The connection with the heat transfer circuit that goes toward the heat exchanger must be the one near the sensor pocket of the last collector of the line The connection with the circuit that comes back from the heat exchanger must be at the bottom of the first collector of the line see the picture above It is also possible to connect more then one line of solar collector...

Страница 6: ...6 12 Water control system 5 7 15 16 17 17 18 b b If copper pipes are used joints must be hot brazed b b We recommend the use of stainless steel pipes spe cially made for solar collectors for the outlet return and probe pipes The probe cable should be of the shielded type b b Do not use plastic or multistrate pipes Operating temperature can exceed 180 C b b Pipe lagging must be able to resist high ...

Страница 7: ... direct sunlight Failure to comply with these precautions could lead to irreparable damage to the product A B Handling HANDLING Once you have removed the outer packaging proceed as follows to unpack and handle the solar collector Remove the PVC wrapping to free the solar collector from the pallet Tilt the solar collector slightly and grip it at the four points shown A to lift it Use a hoist or oth...

Страница 8: ...lation must be protected against damage by the weather and birds and animals Angle of collectors General Solar collectors are designed to be installed at angles of between 15 minimum and 75 maximum Make sure that the bleed and vent valves of the collectors remain open while the collectors are being installed Take care to protect all fittings connections bleed and vent valves against dirt and dust ...

Страница 9: ...solar circuit at ambient temper ature with the collectors shielded from the sun s rays 1 Open the non return valve A 2 Open the air vent at the highest point in the system see figure alongside and keep it open throughout the filling operation 3 Open the vent valve 7 4 Pump the heat transfer fluid around the circuit with an external filling pump until all air bubbles have been eliminated Close the ...

Страница 10: ...very two years MAINTENANCE Collector circuit Cold circuit pressure ____bar see table above Collector circuit seal test Safety valve check Anti freeze checked to ___ C pH of heat transfer fluid ____ Collector circuit bled Flow rate of 30 l h per m2 checked Non return valve functioning Solar collectors Visual check of collectors Collectors cleaned if necessary Visual check of collector fixing points...

Страница 11: ...11 ...

Страница 12: ...LC Italy Customer Service 199 13 31 31 www berettaclima it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore liable to modification without notice ...

Отзывы: