Beretta 20015324 Скачать руководство пользователя страница 5

5

GENERAL

3  descriPtion of tHe 

aPPliance

B

 

IDRA MS

 solar storage cylinders come in capacities 

of 200, 300, 430 and 550 litres, and are designed for in-

tegration in solar domestic hot water production systems 

heated by 

B

solar collectors.

The most important technical features of these solar stora-

ge cylinders are:

 - the storage cylinder and coil are specially designed and 

shaped for optimum performance in terms of stratifica-

tion, heat exchange and replenishment times

 - The double vitrified cylinder lining is bacteriologically 

inert for maximum hygiene, reduced lime scale deposits 

and easy cleaning.

 - CFC-free polyurethane insulation and an elegant external 

casing reduce heat loss and improve efficiency

 - Temperature sensor and power cables are all internally 

routed.

 - A flange is provided for easy cleaning and maintenance 

of the anti-corrosion magnesium anode.

B

 

IDRA MS

 solar storage cylinders can be equipped 

with a special solar controller for easy integration in

B�

solar water heating systems.

4  identification

B

 

IDRA MS

 storage cylinders are identified by:

Data plate

This lists the technical specifications and performance 

of the product.

Beretta Caldaie

Via Risorgimento, 13

23900 Lecco (LC)

Beretta Caldaie

Via Risorgimento, 13

23900 Lecco (LC)

INTERACUMULADOR SOLAR

Modelo

N° Fabric.

Código

Año

Pressão máxima de exercício

Alimentaçcao eléctrica

bar

V-Hz

Capacidade do termoacumulador

l

T067659EPE02

Conexión a tierra obligatoria - Ligação á terra obrigatória - Obligatory ground connection

W

Potência eléctrica consumida

Potência consumida max.pela serp.sup. [T° Primário 80°C]

kW

Caudal especifico sup. [∆T 35°C]

l/1'

TERMOACUMULADOR SOLAR

Ano

Potencia absorbida max.serp.sup. [T° Primário 80°C]

Presión máxima de funcionamiento

Capacidad del interacumulador

Potencia eléctrica absorbida

Alimentación eléctrica

m

2

Superficie serpentín superior

Superfície serpentina superior

Superficie serpentín inferior

Superfície serpentina inferior

m

2

kW

Pot. cons. max.pela serp.sup.

N° Fabric.

Pot. absor. max.serp.sup.

Modelo

m

2

Sup. serpentín inf.

Sup. serpentina inf.

SOLAR STORAGE CYLINDER

Model

Serial number

Code

Year

Power absorbed by top coil (T° primary 80°C)

Domestic Hot Water production - top coil

Maximum working pressure of storage cylinder

Storage cylinder capacity

Electrical consumption

Power supply

Top coil heat exchange surface area

Bottom coil heat exchange surface area

Bottom coil heat exch. surf. area

Serial number

Model

Power absorbed by top coil

Serial number plate

This specifies the serial number and model.

 

b

If these plates or any other means of clearly iden-

tifying the product are defaced, removed or lost, 

proper installation and servicing may be rendered 

difficult.

5  systeM layoUt

1

2

3

4

5

6

7

11

10

9

8

Magnesium anode

Storage cylinder

Temperature gauge

Sleeve for electric heating element (not supplied)

Coil

Flange cover

Cylinder inspection flange

Sensor socket

Insulation

10 

Cover

11 

Plug for anode inspection and lifting

Содержание 20015324

Страница 1: ...solar storage cylinder IDRA MS INSTALLATION MANUAL USER MANUAL SOLAR...

Страница 2: ...ersonnel are specially trained to keep your solar storage cylinder effi cient and cheap to run B service centres also stock any original spare parts that might be required This manual contains importa...

Страница 3: ...ecifications 6 7 Water circuit 7 8 Location of sensors 8 9 Overall dimensions and water fittings 9 INSTALLER 11 10 Unpacking the product 11 11 Handling 11 12 Place of installation 12 13 Installation i...

Страница 4: ...must be mixed with water in a percentage varying from 30 to 50 as instructed in the B installation and maintenance manual b b Only fill the solar collector primary circuit with water and glycol premi...

Страница 5: ...ermoacumulador l T067659EPE02 Conexi n a tierra obligatoria Liga o terra obrigat ria Obligatory ground connection W Pot ncia el ctrica consumida Pot ncia consumida max pela serp sup T Prim rio 80 C kW...

Страница 6: ...450 33 520 mm Flange diameter 118 mm Diameter length of sensor sockets 16 175 mm Sleeve for electric heating element not supplied 1 F Coil water capacity 5 7 9 3 11 12 8 l Coil heat exchange surface...

Страница 7: ...lector probe Note The above schematic is purely indicative b b B IDRA MS storage cylinders are delivered without a boiler heating pump A suitably rated pump must be provi ded and installed separately...

Страница 8: ...the boiler and solar collectors Installers must use their expertise to ensure proper installation and functioning in compliance with all applicable legislation Psr B A C A Temperature sensor socket B...

Страница 9: ...iameter length of solar controller sensor socket 16 175 mm RE Sleeve for electric heating element not supplied 1 F mm AD Diameter length of magnesium anode 33 450 33 520 mm TR Temperature gauge DSA Se...

Страница 10: ...lar controller sensor socket 16 175 mm RE Sleeve for electric heating element not supplied 1 F mm AD Diameter length of magnesium anode 33 450 33 520 mm TR Temperature gauge DSA Sensor power cable ent...

Страница 11: ...n hand to lift the storage cylin der off the pallet using the eyebolt proceed as follows Place a platform of about half the height of the pallet near the storage cylinder Make sure the platform is abl...

Страница 12: ...one Silicon ions less than 30 ppm Technical Assistance Centre 14 Putting into service It is essential to perform the following checks before star ting up or testing the functioning of the storage cyli...

Страница 13: ...Centre or by a qualified heating engineer at least once a year Perform the following operations before beginning any maintenance Switch the electricity supply to the storage cylinder s val ve group a...

Страница 14: ...limiter Fit a flow reducer There are blockages or deposits in the domestic hot water circuit Check and clean as necessary The pump is malfunctioning Check the pump The water temperature from the boile...

Страница 15: ...on the environment and save energy before leaving for the weekend or a short break etc pro vided outdoor temperatures will remain above ZERO sim ply adjust the storage cylinder s thermostat to its min...

Страница 16: ...C Italy Customer Service 199 13 31 31 www berettaclima it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessorie...

Отзывы: