Beretta 20015324 Скачать руководство пользователя страница 1

solar 

storage 

cylinder

idra Ms

installation ManUal

User ManUal

solar

Содержание 20015324

Страница 1: ...solar storage cylinder IDRA MS INSTALLATION MANUAL USER MANUAL SOLAR...

Страница 2: ...ersonnel are specially trained to keep your solar storage cylinder effi cient and cheap to run B service centres also stock any original spare parts that might be required This manual contains importa...

Страница 3: ...ecifications 6 7 Water circuit 7 8 Location of sensors 8 9 Overall dimensions and water fittings 9 INSTALLER 11 10 Unpacking the product 11 11 Handling 11 12 Place of installation 12 13 Installation i...

Страница 4: ...must be mixed with water in a percentage varying from 30 to 50 as instructed in the B installation and maintenance manual b b Only fill the solar collector primary circuit with water and glycol premi...

Страница 5: ...ermoacumulador l T067659EPE02 Conexi n a tierra obligatoria Liga o terra obrigat ria Obligatory ground connection W Pot ncia el ctrica consumida Pot ncia consumida max pela serp sup T Prim rio 80 C kW...

Страница 6: ...450 33 520 mm Flange diameter 118 mm Diameter length of sensor sockets 16 175 mm Sleeve for electric heating element not supplied 1 F Coil water capacity 5 7 9 3 11 12 8 l Coil heat exchange surface...

Страница 7: ...lector probe Note The above schematic is purely indicative b b B IDRA MS storage cylinders are delivered without a boiler heating pump A suitably rated pump must be provi ded and installed separately...

Страница 8: ...the boiler and solar collectors Installers must use their expertise to ensure proper installation and functioning in compliance with all applicable legislation Psr B A C A Temperature sensor socket B...

Страница 9: ...iameter length of solar controller sensor socket 16 175 mm RE Sleeve for electric heating element not supplied 1 F mm AD Diameter length of magnesium anode 33 450 33 520 mm TR Temperature gauge DSA Se...

Страница 10: ...lar controller sensor socket 16 175 mm RE Sleeve for electric heating element not supplied 1 F mm AD Diameter length of magnesium anode 33 450 33 520 mm TR Temperature gauge DSA Sensor power cable ent...

Страница 11: ...n hand to lift the storage cylin der off the pallet using the eyebolt proceed as follows Place a platform of about half the height of the pallet near the storage cylinder Make sure the platform is abl...

Страница 12: ...one Silicon ions less than 30 ppm Technical Assistance Centre 14 Putting into service It is essential to perform the following checks before star ting up or testing the functioning of the storage cyli...

Страница 13: ...Centre or by a qualified heating engineer at least once a year Perform the following operations before beginning any maintenance Switch the electricity supply to the storage cylinder s val ve group a...

Страница 14: ...limiter Fit a flow reducer There are blockages or deposits in the domestic hot water circuit Check and clean as necessary The pump is malfunctioning Check the pump The water temperature from the boile...

Страница 15: ...on the environment and save energy before leaving for the weekend or a short break etc pro vided outdoor temperatures will remain above ZERO sim ply adjust the storage cylinder s thermostat to its min...

Страница 16: ...C Italy Customer Service 199 13 31 31 www berettaclima it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessorie...