Inputs and outputs
Master signal inputs
The Smart Battery Hub has 3 master signal inputs for remote activation. Each master signal input can be
assigned to control any switch on the Smart Battery Hub, or any circuit on a CZone network. Switches can be
grouped together so one master signal input can control multiple switches. Master signal inputs are switched to
ground only inputs. The Smart Battery Hub comes pre-configured with some standalone switch controls.
Default standalone settings for the master signal inputs are:
If you need more than 3 master signal inputs, the 2x Signal interface inputs can be reconfigured as additional
master signal inputs and support switch to positive or negative inputs. If different functionality than the default
configuration is required, you can configure this with the CZone configuration tool.
Master status output
The master status output is used to drive an external LED indicator and shows if the Smart Battery Hub is active
or in Sleep mode. The status output is a switch to ground circuit and is designed to work with an LED with an
externally fused power supply to the LED status indicator.
Signal interface inputs
The two signal interface inputs on the Smart Battery Hub can be used to connect additional mechanical switches
to control circuits or can be used for connecting external analogue sensors and senders (0-30V, 0-
1000Ω or
4-20mA). The Smart Battery Hub will convert the analogue sensor values and transmit them over NMEA 2000
network as digital sentences. Connected sensors will need to be configured with the CZone configuration tool.
24hr Fused Outputs
The Smart Battery Hub has two additional 10A 24hr fused outputs, these outputs can be used for such tasks as
powering the NMEA2000 bus or suppling power for Master Status Output LEDs.
Pin Function
Color
5
Master signal
input 1
Brown
All Engine Battery Switches Toggle ON/OFF
6
Master signal
input 2
Brown
with White
House Battery Switch Toggle ON/OFF
7
Master signal
input 3
White with
black
All Emergency Parallel Switches Toggle ON/OFF
Pin Function
Color
11 Left fuse #1 (10A)
Red
Fused 24hr output from the house bank
12 Right fuse #2 (10A)
Yellow
Fused 24hr output from the house bank
10A Fuses