TGR-86 WIFI THERMOSTAT USER GUIDE
8
Advanced options
When POWER OFF, press the
key and the
key for 5 seconds to enter the
advanced option setting.
Press
to enter the next option, press
and
to adjust, and press
to exit the
height Level option.
1
Temperature compensation
The default value of the calibration room temperature is -2
℃
. Press the up and down keys
to adjust. The adjustable range is 9.9 °C to -9.9
℃
.
2
Sensor selection
The temperature sensor is selected as IN by default. Press the up and down keys to adjust as
IN respectively, indicating that the internal.
3
Modify the temperature limit
The default temperature limit value is 35
℃
. Press the up and down keys to adjust the range
from 5
℃
to 60
℃
.
4
Temperature difference start
The default temperature difference is set to 1
℃
. Press the up and down keys to adjust the
range to 1-10 degrees.
5
Antifreeze fundion
Set the default anti-freeze function to OFF, display OFF, press the up key to tum on
anti-freeze and display ON
6
Holiday option and turn off weekly
programming
Set tfie default rest day as double OFF. Press the up and down keys to adjust It to double
OFF (1-5), single OFF (1-6), no OFF (1 -7) and tum off week programming (OFF).
7
Primary and secondary reverse
selection
Set the default main and auxiliary reversal to 0. Press the up and down keys to adjust 0 to
tum off the main and auxiliary reversal. 01 means auxiliary reverse, 02 means auxiliary
reverse, 03 means main and auxiliary reverse, shutdown and antifreeze is not on, stop
output
8
Passive linkage output delay time Set the default passive linkage delay time to 0. Press the up and down keys to adjust the
range of 0-5 minutes.
9
Set upper temperature limit
The default value of the set temperature upper limit i$ 60 'C, and the adjustment range Is
35-95
℃
by pressing the up and down keys.
10
Restore Fartory Defaults
Set to restore the factory default setting to display “-”, Press the up button to adjust tfie
display "---”, press the enter button to restore the factory settings