VIII
.
Operation Instruction
2
.
Power-off memory
function.
3
.
Real-time data save function.
.
4 5+2 or 6+1or 7days six periods progra
m
schedule.
5
.
S
electable
80mmx80mm European hidden box.
Accuracy
Floor Set Temp. Range
Sensing Element
Power Consumption
Power Supply
Current Load
External Material
Dimension
Ambient Temp.
Storage Temp.
±
1
℃
5-99
℃
NTC
<0.3W
200 ~ 240V 50 ~60Hz
≤
3A
(
water
heating
)
PC+ABS (flame retardant
)
86x86x13.3mm
0-45
℃,
5-95
%
RH(Non
-
condensing
)
-5~55
℃
Set Temp. Range
5-60
℃
I. Product Summary:
II. Technical Parameter:
IV. User Interface Explanation
1
.
Popular
square
LCD screen display with blue backlight.
TDS23M series
thermostats are luxurious programmable thermostat
with
square screen display
.
It is applied
to
temperature control of
industrial,
commercial
and
domestic room, and
start of
control
heating appliance,
especially
used
in
the
floor heating
systems
.
≤
16A
(
electric heating)
Timing Error
<1
%
V. Model Definition
WP: For Water Heating System, 3A
EP: For Electric Floor Heating System, 16A
For example: TDS23M-EP TDS23M-WP
1. Setting Power on/off
Press to turn on/off the power.
2. Setting Temperature
Press to set the temperature.
3. Setting the Clock
Press to set minute, hour and week.
Press for adjusting.
4. Setting the Manual Mode.
Manual mode means non-programmable mode.
will display in the screen, it is in manual mode.
Press to set the temperature.
Press to set minute, hour and week.
6. Setting the Programmable Mode.
Press and hold into programmable mode. LooP and 12345 will display.
Press to select the control way: 5+2 or 6+1 or 7 days programmable.
12345 display in the position of week means 5+2;
123456 display in the position of week means 6+1;
1234567 display in the position of week means 7 days programmable.
Press
to select the periods.
Press to change the temperature;
Press to do time adjustment.
Press to change the time;
Press again to select the weekend's temp.
If you want to make temporary adjustment in any period,
press then will flash. When finish the setting, all will confirm
automatically.
6
.
Precise comfort control keeps temperature within1°C of the level you set.
Remark:
(1) The defaulted temperature of period3 and period4 is the same as
period2. Please change it according to the request.
(2) When setting temperature is 00, this period is power off.
(3) How to check floor temp?
During power on, press and hold then press the button of power to
check floor temp.. OUT TEMP will display.
Press
again to display room temp..
Period
Week
Weekend
Period Icon Defaulted Time Defaulted Temp.
1
2
3
4
5
6
1
2
6:00
8:00
11:30
12:30
17:30
22:00
8:00
23:00
20
℃
15
℃
15
℃
15
℃
22
℃
22
℃
15
℃
15
℃
TDS23M LCD SCREEN THERMOSTAT
VII.Wiring Digram
TDS23M-EP
TDS23M-WP
III. Main Functions and Characteristics
VI. Model Spec
TDS23M-EP
TDS23M-WP
Optional
Optional
Long press to enter into child lock mode, will display.
5. Setting the Child Lock
Long press again, the child lock will be disappeared.
Press to switch operation between manual mode and programmable
mode.
Press then
7.With
Rs485
communication
Mod-bus
Rs485
Modbus
Function
Memory
Function