27
Bentone
6.2 Servicing air dampers
Removal and installation
1.
Break the main current and disconnect the Euro plugs from the burner.
2.
Undo the nuts (H) and pull out the burner body on its guides.
3.
Remove the intake grille from the air intake.
4.
Release the damper motor.
5.
Clean the air damper (F) and the intake. Lubricate the damper shaft if
applicable.
6.
Re-engage the damper motor.
7.
Fit the intake grille over the air intake.
8.
Slide the burner together and secure it with the nuts (H).
9.
Connect the Eurostecker connectors and turn on the main power
switch.
10. Check combustion.
H
F
!
If the burner is directly connected, ensure that all
components on the burner are without power.
165 205 36 2020-11-02/2
!
When servicing/replacing components that affect combustion, an analysis and
soot test must be carried out on the installation.