Содержание Omnia 8/L

Страница 1: ......

Страница 2: ...has been developed and made according to the highest standards of quality reliability and performance adopted by BENTEL SECURITYsrl Installation of the control panel must carried out strictly according to the instructions andincompliancewiththesafetylawsinforce To make sureyoursystemcontinuestoworkasintended youmusttestyour system every month Consult the installer for testing and maintenance instr...

Страница 3: ...TABLE OF CONTENTS PARTS 5 The Panel 5 INSTALLATION 6 Mounting the Panel 6 Terminal board 6 Power supply connection 8 Open Panel 8 A Typical System 9 NCDUEVOX voice board 12 3 ...

Страница 4: ...P Figura 1 Omnia8 L Parts 4 Security System Control panel Omnia 8 L ...

Страница 5: ...tor for the 3 A switching power supply BAQ35 or BAW35 optional 10 Cable hole 11 Mains connection terminals 230 V 10 150 mA 12 Housing for 13 8 V 7 Ah standby battery optional 13 Service mode jumper Connection of this jumper will disable the Alarm outputs for maintenance purposes 14 Battery connectors 15 Firmware Release to be communicated to Service dealer 16 NCDUEVOX voice board optional LEDs STA...

Страница 6: ... voice board if used Step 4 Pull the wires through the hole 10 and mount the back box Terminal board Below is a description of the Panel terminal board keypads and key read ers Ø The Terminal column shows the terminal number and terminal identifier in square brackets Ø The DESCRIPTION column provides a description of each terminal The V column shows the voltage on the corresponding terminal The I ...

Страница 7: ...ge on terminal 13 8 2 37 N Terminal for self powered sirens Standby status è voltage on terminal Alarm status è terminal open 13 8 1 34 35 36 NC COM NO Voltage free alarm relay contacts Standby status è NC connected to COM and NO open Alarm status è NO connected to COM and NC open 3 31 K Auxiliary terminal to Arm Disarm the Control panel by means non standard BPI devices keylock switch digital key...

Страница 8: ...ll supply the power during mains failure Mains failure will be signalled as follows Ø The MAIN LED on the Panel will go OFF Ø The TROUBLE LED on the Control Keypad will go ON Ø Activation of one of the auxiliary outputs 39 O1 40 O2 41 O3 42 O4 if programmed to signal TROUBLE The cause of trouble must always be eliminated before the battery emp ties Total power failure mains and battery will not af...

Страница 9: ...to line L1 Ø Connection of three fire sensors to line L8 Ø Connection of the Tamper line to the siren Ø Connection of additional devices Keypad and Key reader to the BPI bus Please note Ø Line L1 must be programmed as Double Balanced This configuration provides tamper detection and requires 2 wires only Ø Line L8 must be programmed as Fire and the auxiliary output terminal 42 O4 as Fire GND Normal...

Страница 10: ...Figure 2 A Typical System ...

Страница 11: ...INSTALLATION 11 ...

Страница 12: ...one to the top Step 3 Connect the NCDUEVOX cable 40 to the connector 4 on the Panel board Step 4 When the NCDUEVOX board is properly attached complete the connec tions then power the Panel and record the alarm messages as per the in structions in the INSTALLATION MANUAL The optional OmniaVox MS and Speaker will allow Remote Listen in on ambients other than that of the Panel Locate the OmniaVox MS ...