14
Multifunction Control Panel
®
®
7. Carry out coding of the Device by means of the first 5 microswitches on the
Minidip [88], as shown in Table 2.2 (microswitch no. 1 must be left in the
OFF position).
8. Set the operating mode for the tamper switch [77] and snatch microswitch
[82] using jumper [78]:
J
= Switches enabled;
K
= Switches disabled.
9. Set the operating mode using microswitches 6 and 7 on DIP switch [88] as
shown in the following table:
10. Set the operating mode of the Inputs using microswitch 8 on DIP switch [88]
as shown in the following table: