background image

TABLE OF CONTENTS

1. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

1.1 How To Use This Manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.2 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.3 Theory of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

2. TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

2.1 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.2 Physical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

3. INSTALLATION OF THE REMOTE RTD MODULE . . . . . . . . . . . . . . . . . . 8

3.1 Physical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.2 Power Wire Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.3 RS-485 Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.4 RTD Wire Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.5 Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

4. COMMUNICATING WITH THE REMOTE RTD MODULE . . . . . . . . . . . . . 10

4.1 Modbus Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.2 Modbus Input Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.3 Modbus Holding Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.4 Modbus Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.5 Modbus Exception Responses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4.6 Indicating LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

iii

TABLE OF CONTENTS

Содержание SPR-100P

Страница 1: ...The Leader In Solid State Motor Control Technology Publication 890010 00 04 REMOTE RTD MODULE ...

Страница 2: ......

Страница 3: ...ION OF THE REMOTE RTD MODULE 8 3 1 Physical Installation 8 3 2 Power Wire Connections 8 3 3 RS 485 Wiring 8 3 4 RTD Wire Connections 9 3 5 Wiring Diagram 9 4 COMMUNICATING WITH THE REMOTE RTD MODULE 10 4 1 Modbus Communications 10 4 2 Modbus Input Registers 10 4 3 Modbus Holding Registers 11 4 4 Modbus Commands 11 4 5 Modbus Exception Responses 12 4 6 Indicating LEDs 13 iii TABLE OF CONTENTS ...

Страница 4: ...s The RTD Module provides the following features Monitors up to 8 3 wire RTDs Lead Resistance Compensation RTD open detection RTD shorted detection Modbus communications over RS 485 1 3 Theory of Operation General The Remote RTD Module makes a compensated measurement of a RTD Resistive Temperature Device This is accomplished by using three wires to connect the RTD to the module The Remote RTD modu...

Страница 5: ...wo equations and subsituting Rlead for the different lead resistance provides the following V V 30mA R 10mA R 30mA R RH CR lead RTD lead V V 10mA R RH CR RTD This calculation gives the voltage across the RTD independant of the connection wire resistance By performing this calculation the Remote RTD Module compensates for the conductor resistance and gets the true value for the RTD resistance The R...

Страница 6: ... full scale 2 C or 3 6 F Sampling Rate 1 RTD per second Number of RTDs 8 Input Voltage 24 Volts DC 20 Power Consumption 2 5 Watts Inrush Current 15 Amps for 5 m seconds Communication Type RS 485 Communication Protocol Modbus RTU Modbus Addresses 16 to 23 Baud Rate 19200 bps Operating Environment 40 to 60 C 40 to 140 F up to 95 R H non condensing Storage Environment Up to two years at 40 to 70 C 40...

Страница 7: ...2 2 Physical Construction The following diagram shows the physical construction of the Remote RTD Module 7 2 TECHNICAL SPECIFICATIONS ...

Страница 8: ...g RS 485 Communications The RS 485 communications wiring should use shielded twisted pair cable The shield should only be terminated at one end The connections are as follows A RS485 negative communications connection B RS485 positive communications connection Com RS485 common connection RS 485 Cable Specification The RS 485 communications cable should conform to the following specification Conduc...

Страница 9: ...compensation RTD Cable Shielding The RTD cable shield should be terminated at either of the shield terminals For a simpler installation a cable containing multiple triads with an overall shield can be used to connect a group of RTDs to the module with a single cable 3 5 Wiring Diagram General The following is the wiring diagram detailing the connections of the RTD module Only the wiring for RTD 5 ...

Страница 10: ...003 RTD 3 0 to 200 Temperature in degrees Celsius 30004 RTD 4 0 to 200 Temperature in degrees Celsius 30005 RTD 5 0 to 200 Temperature in degrees Celsius 30006 RTD 6 0 to 200 Temperature in degrees Celsius 30007 RTD 7 0 to 200 Temperature in degrees Celsius 30008 RTD 8 0 to 200 Temperature in degrees Celsius 30009 Shorted RTD A bit is set if an RTD has a shorted lead Otherwise it is clear The set ...

Страница 11: ...mote RTD Module supports the following Modbus commands Read input registers function code 04h Read holding registers function code 03h Preset single register function code 06h Format All Modbus messages have the following format Address Function code Data CRC 16 1 byte 1 byte n bytes 2 bytes Read Input Registers Function code 04h is used to read one or more consecutive input registers The first re...

Страница 12: ...r Data CRC 16 10h 06h 00 00h 00 07h CB 49h The Remote RTD Module will respond with this echo of the command Address Function Code Starting Register Number of Registers CRC 16 10h 06h 00 00h 00 07h CB 49h 4 5 Modbus Exception Responses General There are four different communications errors the Remote RTD Module will recognize and respond to They are CRC Error Illegal Function exception code 01 Ille...

Страница 13: ...CRC code 10h 83h 02h 90 F4h Illegal Data Value If the Remote RTD Module receives a preset single register command that contains an illegal value it will respond with and illegal data value exception response The response will be in the form Byte 1 RTD module address Byte 2 Function code with most significant bit set to 1 indicating an exception Byte 3 Exception code 03h indicating an illegal value...

Страница 14: ......

Страница 15: ...Revision History Revision Date ECO 00 16 11 99 01 23 02 00 02 24 02 00 03 31 03 00 04 28 04 00 088 ...

Страница 16: ...erica Sao Paulo Brazil Santiago Chile Singapore BENSHAW Inc 1659 East Sutter Road Glenshaw PA 15116 Phone 412 487 8235 Fax 412 487 4201 BENSHAW West 14715 North 78th Way Suite 600 Scottsdale AZ 85260 Phone 480 905 0601 Fax 480 905 0757 BENSHAW Canada 550 Bright Street Listowel Ontario N4W 3W3 Phone 519 291 5112 Fax 519 291 2595 Visit us at http www benshaw com Distributed by BENSHAW PRODUCTS Pump ...

Отзывы: