Perform Basic Operations
39
890054-00-00
GM2 Series VFD
Parameter Initialization
The following demonstrates parameter initialization using code dr.93 (Parameter Initialization) in
the Drive group.
Jumping to parameter dr.93 is used.
Step
Instruction
Keypad Display
1
Go to code 0 in the Drive group.
2
Press the [ENT] key.
The current parameter value "9" will be displayed.
3
To make the target value "93", press the [
▼
] key to
change the ones' position to "3".
4
Press the [MODE/SHIFT] key to move to the tens'
position.
5
To make the target value "93", press the [
▲
] or [
▼
] key
to change the tens' position value "9".
6
Press the [ENT] key.
Code dr.93 will be displayed.
7
Press the [ENT] key once again.
The current value for parameter dr.93 is set to 0 (No, do
not initialize).
8
Press the [▲] key to change the value to 1 (All Grp), and
then press the [ENT] key.
The parameter value will flash.
9
Press the [ENT] key once again.
Parameter initialization begins. Parameter initialization is
complete when code dr.93 reappears on the display.
Note
Following parameter initialization, all parameters are reset to factory default values. Ensure
that parameters are reconfigured before running the inverter.
dr.0
9
3
0
3
9
3
dr.93
0
1
dr.93
Содержание RSi GM2 Series
Страница 2: ...ii...
Страница 58: ...48 GM2 Series VFD Perform Basic Operations 890054 00 00...
Страница 122: ...Learning Advanced Features 112 890054 00 00 GM2 Series VFD PID control block diagram...
Страница 188: ...Learning Protection Features 178 GM2 Series VFD 890054 00 00...
Страница 279: ...Technical Specification 269 890054 00 00 GM2 Series VFD...