background image

12 

 

Hex 

0x38 

0x30 

0x35 

0x72 

0x62 

0x30 

0x36 

0x37 

0x0D 

 
Example 3: Get Tint from TV-0007 and this command is valid.   
The Tint value is 32. 
Send (Hex Format) 

 

Name

 

 

Length

 

 

ID

 

Command 

type

 

 

Command

 

 

Value1

 

 

Value2

 

 

Value3

 

 

CR

 

Hex 

0x38 

0x30 

0x37 

0x67 

0X65 

0x30 

0x30 

0x30 

0x0D 

 

 

Reply (Hex Format) 

 

Name

 

 

Length

 

 

ID

 

Command 

type

 

 

Command

 

 

Value1

 

 

Value2

 

 

Value3

 

 

CR

 

Hex 

0x38 

0x30 

0x37 

0x72 

0x65 

0x30 

0x33 

0x32 

0x0D 

 

Example 4: Get Tint from TV-07, but the Brightness command ID is error and it is NOT in the  command 
table. 

Send (Hex Format) 

 

Name

 

 

Length

 

 

ID

 

Command 

type

 

 

Command

 

 

Value1

 

 

Value2

 

 

Value3

 

 

CR

 

Hex 

0x38 

0x30 

0x37 

0x67 

0XD7 

0x30 

0x30 

0x30 

0x0D 

 

Reply (Hex Format) 

 

Name

 

 

Length

 

 

ID

 

Command 

type

 

 

CR

 

Содержание RM5501K

Страница 1: ...1 RM5501K RM6501K RM7501K RM8601K RS232 LAN Protocol Installation Guide ...

Страница 2: ...cation settings 4 RS232 serial port with a straight cable 4 RS232 via LAN 5 RS232 via HDBaseT 5 Protocol Command Description 5 Set function listing 6 Set function description 6 Set function format 6 Set function table 8 Get function listing 10 Get function description 10 Get function format 10 PC Get function command to LCD Monitor 15 Date 2019 03 20 ...

Страница 3: ... The set protocol contains two sections command Set Function and Get Function In this document PC represents all the control units that can send or receive the RS232 protocol command Wire arrangement Wire Arrangement P1 Color P2 1 Black 1 2 Brown 3 3 Red 2 4 Orange 4 5 Yellow 5 6 Green 6 7 Blue 7 8 Purple 8 9 Gray 9 Case Drain wire Case RS232 pin assignment Pin Description Pin Description 1 NC 2 R...

Страница 4: ...all response as follows 1 If the message is received correctly it will send 02Bh followed by CR 00Dh 2 If the message is received incorrectly it will send 02Dh followed by CR 00Dh Connections and communication settings Choose one of the connections and set up properly before RS232 control RS232 serial port with a straight cable PC or laptop D Sub port male or female on a display D Sub 9 pin female...

Страница 5: ...of Message excluding CR TV ID Identification for each of TV Command Type Identify command type s 0x73h Set Command g 0x67h Get Command r 0x72h Reply Command 0x2Bh Valid command Reply 0x2Dh Invalid command Reply Command Function command code One byte ASCII code Value 1 3 Three bytes ASCII that defines the value CR 0x0D PC or laptop LAN cable RJ45 port on a display HDBaseT compatible device D Sub 9 ...

Страница 6: ... Identify command type s 0x73h Set Command Command Function command code One byte ASCII code Value 1 3 Three bytes ASCII that defines the value CR 0x0D Set function format Send Command Type s Name Length ID Command type Command Value1 Value2 Value3 CR Byte count 1 Byte 2 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte Bytes order 1 2 3 4 5 6 7 8 9 Reply Command Type or Name Length ID Command type C...

Страница 7: ...ame Length ID Command type Command Value1 Value2 Value3 CR Hex 0x38 0x30 0x32 0x73 0x24 0x31 0x37 0x36 0x0D Reply Hex Format Name Length ID Command type CR Hex 0x34 0x30 0x31 0x2D 0x0D Example 3 Set Tint as 32 for TV 03 and this command is valid Send Hex Format Name Length ID Command type Command Value1 Value2 Value3 CR Hex 0x38 0x30 0x33 0x73 0x27 0x30 0x33 0x32 0x0D Reply Hex Format Name Length ...

Страница 8: ...0x31 0x2D 0x0D Example 5 Set Brightness as 76 for all TV and this command is valid Send Hex Format Name Length ID Command type Command Value1 Value2 Value3 CR Hex 0x38 0x39 0x39 0x73 0x24 0x30 0x37 0x36 0x0D No Reply Set function table Value Range ASCII Bytes Set Function Len ID Cmd Type Cmd Code Hex RS232 Control LAN Control Power 8 s 21 000 Monitor Off 000 Monitor Off 001 Android On Monitor On 0...

Страница 9: ...Just Scan 006 14 9 007 PC Mode Language 8 s 32 000 English 001 Français 002 Español 003 繁中 004 简中 005 Português 006 German 007 Dutch 008 Polish 009 Russia 010 Czech 011 Danish 012 Swedish 013 Italian 014 Romanian 015 Norwegian 016 Finnish 017 Greek 019 Arabic 020 Japanse 021 Thailand 023 Hungarian 024 Persian 025 Vietnamese Volume 8 s 35 200 Volume 200 Volume 300 Volume 300 Volume ...

Страница 10: ...ific information The Get Function packet format consists of 5 bytes which are similar to the Set Function packet structure Note that the Value byte is always 00 Get function description Item Description Length Total Bytes of messages excluding CR TV ID Identification for each of TV Command Type Identify command type g 0x67h Get Command Command Function command code One byte ASCII code Value 1 3 Th...

Страница 11: ...2 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte Bytes order 1 2 3 4 5 6 7 8 9 If the Command is Not valid Command Type Name Length ID Command type CR Byte count 1 Byte 2 Byte 1 Byte 1 Byte Bytes order 1 2 3 4 5 Example 1 Get Brightness from TV 05 and this command is valid The Brightness value is 67 Send Hex Format Name Length ID Command type Command Value1 Value2 Value3 CR Hex 0x38 0x30 0x35 0x67...

Страница 12: ...67 0X65 0x30 0x30 0x30 0x0D Reply Hex Format Name Length ID Command type Command Value1 Value2 Value3 CR Hex 0x38 0x30 0x37 0x72 0x65 0x30 0x33 0x32 0x0D Example 4 Get Tint from TV 07 but the Brightness command ID is error and it is NOT in the command table Send Hex Format Name Length ID Command type Command Value1 Value2 Value3 CR Hex 0x38 0x30 0x37 0x67 0XD7 0x30 0x30 0x30 0x0D Reply Hex Format ...

Страница 13: ...alue1 Value2 Value3 Value4 CR Hex 0x39 0x30 0x37 0x72 0X6F 0x31 0x37 0x38 0x36 0x0D Example 6 Get ambient sensor from TV 0007 and this command is valid The lux value is 1568 ASCII code Send Hex Format Name Length ID Command type Command Value1 Value2 Value3 Value4 CR Hex 0x39 0x30 0x37 0x67 0X70 0x30 0x30 0x30 0x30 0x0D Reply Hex Format Name Length ID Command type Command Value1 Value2 Value3 Valu...

Страница 14: ...mmand Value1 Value2 Value3 Value4 CR Hex 0x39 0x30 0x37 0x72 0X71 0x2B 0x30 0x37 0x35 0x0D Example 8 Get Running Hours from TV 0007 and this command is valid The value is 21 356 hours ASCII code Send Hex Format Name Length ID Command type Command Value1 Value2 Value3 Value4 Value5 CR Hex 0x3A 0x30 0x37 0x67 0X76 0x30 0x30 0x30 0x30 0x30 0x0D Reply Hex Format Name Length ID Command type Command Val...

Страница 15: ... the same as the value of Byte1 at input value Byte2 Byte15 should be ASCII format Ex If Customer Generic Byte1 0x01 Byte2 G Byte3 e Byte8 c Byte9 Byte11 0x00 Ex If the Scaler Firmware Version 1 02 Byte1 0x03 Byte2 1 Byte3 Byte4 0 Byte5 2 Byte6 Byte11 0x00 Signal Status 8 g 22 000 Signal unstable 001 Signal stable Active Sync exists Volume 8 g 66 000 100 000 100 Mute 8 g 67 000 Off 000 Off 001 On ...

Страница 16: ... 006 German 007 Dutch 008 Polish 009 Russia 010 Czech 011 Danish 012 Swedish 013 Italian 014 Romanian 015 Norwegian 016 Finnish 017 Greek 019 Arabic 020 Japanse 021 Thailand 023 Hungarian 024 Persian 025 Vietnamese Network Setting 14 g E1 Input Value Byte1 Byte2 Byte3 Byte9 1 Byte1 0x00 IP Setup Mode Byte1 0x01 IP Address Byte1 0x02 Get Subnet Mask Byte1 0x03 Default Gateway Byte1 0x04 Primary DNS...

Страница 17: ... reserved should be 0x00 2 If Byte1 0x01 IP Address at Input value the return value should be Ex IP address 169 254 81 38 Byte1 0x01 same as Byte1 at Input value Byte2 0xA9 169 Byte3 0xFE 254 Byte4 0x51 81 Byte5 0x26 38 Byte6 9 are reserved should be 0x00 3 If Byte1 0x02 0x05 at Input value refer to 2 4 If Byte1 0x06 MAC Address at Input value the return value should be Ex MAC address 00 22 64 7E ...

Отзывы: