background image

                                                                                   

Last revised: December 2011

                                                                                                                                 

9

 

Regular cleaning of the module

Regular cleaning of the module

Regular cleaning of the module

Regular cleaning of the module    
Dirt  piled  up  on  the  module’s  transparent  surface  reduces  its  performance  and  may  cause 
reverse hot spot effects. The problem may become serious in the case of industrial waste and 
bird droppings. The intensity of the effect depends on the waste’s opacity. The layers of dust 
that  reduce  the  sun’s  intensity  evenly  are  not  dangerous  and  the  power  reduction  is  not 
usually  significant.  The  frequency  of  cleaning  depends,  of  course,  on  how  quickly  dirt 
accumulates. In many cases, rainfall may reduce or remove the need to clean the modules. 
 
The  cleaning  operation  must  be  performed,  in  general,  by  the  user.  It  simply  consists  of 
washing the modules with water and non-abrasive detergent. 
    
Visual inspection of the module

Visual inspection of the module

Visual inspection of the module

Visual inspection of the module    
The purpose of visual inspection of the module is to detect possible faults, specifically: 

 

Possible broken glass.   

 

Rust  on  the  circuits  and  soldering  of  the  PV  cells:  this  is  normally  due  to  moisture 
entering the module through a breakage in the encapsulating layer during installation or 
transport. 

    
Inspection of connections and cabling

Inspection of connections and cabling

Inspection of connections and cabling

Inspection of connections and cabling    
Perform preventive maintenance every 6 months, carrying out the following operations: 

 

Check the tightness and condition of the connection cable junctions.   

 

Check the junction box sealing. Should sealing faults be observed, the items which have 
been  affected  should  be  replaced  and  cleaned.  It  is  important  to  monitor  the  junction 
box sealing by using new sealing methods such as silicon sealing according to the case. 

 
 

Certifications 

 

IEC

IEC

IEC

IEC 

– 

The PV modules provided by BenQ Solar all pass the design qualification and type 
approval standard IEC 61215 editions 2. 

– 

The PV modules provided by BenQ Solar all pass the safety qualification standard 
IEC

IEC

IEC

IEC    61730

61730

61730

61730 certified for application class A. 

– 

Modules qualified for safety through EN IEC61730-1 and -2 within this application 
class are considered to meet the requirements for Safety Class II. 

 

ET

ET

ET

ETL

LL

L    

This product meets or exceeds the requirements set forth by UL1703 for PV Modules. 
This  UL1703  Standard  covers  flat-plate  PV  modules  intended  for  installation  on 
buildings and those intended to be freestanding. To satisfy the listing for this product 
the modules must be mounted with a rack or standoff structure. It does not include 
integration  into  a  building  surface  because  additional  requirements  may  apply.  This 
product is not intended for use where artificially concentrated sunlight is applied to 
the module.    

 

 

 

 

BenQ Solar is a division of AU Optronics 
© Copyright AUO Optronics Corp. All rights reserved. Information may change without notice. 

 

Содержание PM220P00

Страница 1: ...B Be en nQ Q S So ol la ar r P Ph ho ot to ov vo ol lt ta ai ic c M Mo od du ul le es s I IE EC C E ET TL L PM220P00 PM240P00 Installation Guide for Users...

Страница 2: ...ncluding but not limited to installation application or removal by any party other than a qualified personnel non observance of BenQ Solar s installation users and or maintenance instructions repair o...

Страница 3: ...modules Damaged modules broken glass torn back sheet broken j boxes broken connectors etc can be electrical hazards as well as laceration hazards Contact with damaged module surfaces or module frame c...

Страница 4: ...iation the temperature of the cells and the equipment to which they are connected a PV module will generate a different current and voltage levels which result in a different power output Grounding Be...

Страница 5: ...uld void the warranty Use corrosion proof fastening materials For PM220P00 and PM240P00 modules four stainless steel bolts with nuts washers and lock washers are recommended per module Only the existi...

Страница 6: ...Last revised December 2011 5 BenQ Solar Figure 2 Installation of module Figure 3 Effective mounting area clamping...

Страница 7: ...ge or adjustment on the cable of Junction Box D D D DO O O O NOT NOT NOT NOT disconnect cable by yourself Important The cable must not be bent or crushed on the direct exit of the cable screw joint A...

Страница 8: ...the southern hemisphere The module must be installed so that air can freely circulate around it The cells working temperature will thus be reduced and consequently the module s performance will be en...

Страница 9: ...the PV conductor which cross section is 4 mm2 External connection boxes will be used to enable greater cable cross section area for long distance transmission The modules are qualified for the applic...

Страница 10: ...g Inspection of connections and cabling Perform preventive maintenance every 6 months carrying out the following operations Check the tightness and condition of the connection cable junctions Check th...

Отзывы: