3
3. Engineering Specification
Superscripts indicate the method in Appendix B used for a given measurement, unless otherwise
noted.
1.0 Image Quality
All tests must adhere to the assumptions in Appendix A
1.1 Brightness
(In ‘optical test’ mode)
1.1.1 Typical
660 ANSI Lumens
1.1.2 Minimum
450 ANSI Lumens
1.2 Brightness Uniformity
(In ‘optical test’ mode)
1.2.1 Typical
73 %
1.2.2 Minimum
60 %
1.3 Contrast Ratio
(In ‘optical test’ mode)
1.3.1 Peak Contrast
1400:1 (Minimum)
1.4 Light Leakage
1.4.1 Blue Edge
Procedure: Test @ distance 3m with 100% white pattern
Criteria: Color coordinate
Δ
x,
Δ
y
≦
0.015 (compared with the
center)
1.4.2 Light Leakage out of
Active Area
< 1 lux @ diagonal 60”
1.4.3 Reflective Edge
Condition: distance 3m or image of 100” wide
Test Pattern:
without connecting any source to projector
Criteria:
No horizontal and vertical lines outside of the image
1.4.4 Blemish / Dust
Test Pattern: Blue 90 with linear de-gamma /
Gray 6
Criteria: Follow HD2 DMD image quality specifications
1.5 Color
All Color Measurements must adhere to the assumptions in
Appendix A
TBD --PPR final
X
Y
1.5.1 100% Gray (White)
.274 ± .04
.318 ± .04
1.5.4 Red
.647 ± .04
.341 ± .04
1.5.5 Green
.304 ± .04
.566 ± .04
1.5.6 Blue
.129 ± .04
.080 ± .04
1.6 Color Uniformity
20
x y
1.6.1 100% Gray (White)
1.6.2.1 L1->L9
±.04 ±.04
1.6.2.2 E10->E13
±.04 ±.04
1.7 Mirror Defects / Dot Defects
Dark pixels<=2
, bright pixels =0 (See Appendix D)
1.8 Image Distortion
Pincushion
1.0%
All manuals and user guides at all-guides.com