5.3 White-Balance, Luminance Adjustment
Approximately 30 minutes should be allowed for warm up before proceeding white balance adjustment.
Before started adjust white balance , please set the Chroma-7120 MEM Channel 3 to Reddish (5800K)
color, MEM Channel 4 to Normal (6500K) color, MEM Channel 9 to Bluish (9300K) color , and MEM
Channel 10 to sRGB color ( our Reddish color parameter is x = 326 ±20, y = 342 ±20, Y
≥
200±20cd/m
2
;
Normal color parameter is x = 313±20, y = 329 ±20, Y
≥
220±20cd/m
2
; Bluish color parameter is x = 283
±20, y = 297 ±20, Y
≥
180±20cd/m
2
; sRGB color parameter is x = 313 ±30, y = 329 ±30,
Y=200±20cd/m
2
)
How to setting MEM channel you can reference to chroma 7120 user guide or simple
use “ SC” key and
“ NEXT” Key
to modify xyY value and use “ID” key to modify the TEXT
description Following is the procedure
to do white-balance adjust .
2. Setting the color temp. you want
A. MEM.CHANNEL 3 (Reddish color):
Reddish color temp. parameter is x = 326 ±20, y = 342 ±20, Y
≥
200±20cd/m
2
B. MEM.CHANNEL 4 (Normal color):
Normal color temp. parameter is x = 313±20, y = 329 ±20, Y
≥
220±20cd/m
2
C. MEM.CHANNEL 9 (Bluish color):
Bluish color temp. parameter is x = 283 ±20, y = 297 ±20, Y
≥
180±20cd/m
2
D. MEM.CHANNEL 10 (sRGB color):
sRGB color temp. parameter is x = 313 ±30, y = 329 ±30, Y=200±20cd/m
2
3. Into Factory mode of BENQ G2200W:
Turn off the monitor, keep pressing the ENTER button, and turn on the monitor , then when we press the AUTO
button, the factory OSD will be at the left top of the panel.
4. Bias adjustment:
Set the
Contrast
to 50; Adjust the
Brightness
to 100.
5. Gain adjustment:
Move cursor to “-F-” and press MENU key
A. Adjust Reddish (5800K) color-temperature
1. Switch the chroma-7120 to
RGB-Mode
(with press “MODE” button)
2. Switch the MEM. channel to Channel 3 (with up or down arrow on chroma 7120)
3. The LCD-indicator on chroma 7120 will show x = 326 ±20, y = 342 ±20, Y
≥
200±20cd/m
2
4. Adjust the RED on factory window until chroma 7120 indicator reached the value R=100
5. Adjust the GREEN on factory window until chroma 7120 indicator reachedthe value G=100
6. Adjust the BLUE on factory window until chroma 7120 indicator reached the value B=100
7. Repeat above procedure (item 4,5,6) until chroma 7120 RGB value meet the tolerance =100±2
B. Adjust Normal (6500K) color-temperature
1. Switch the chroma-7120 to
RGB-Mode
(with press “MODE” button)
2. Switch the MEM. channel to Channel 4(with up or down arrow on chroma 7120)
3. The LCD-indicator on chroma 7120 will show x = 313±20, y = 329 ±20, Y
≥
220±20cd/m
2
4. Adjust the RED on factory window until chroma 7120 indicator reached the value R=100
Содержание G2200W - 22" LCD Monitor
Страница 8: ...22 LCD Color Monitor BenQ G2200W 8 3 3 Factory Preset Display Modes ...
Страница 10: ...22 LCD Color Monitor BenQ G2200W 10 Optical Characteristics ...
Страница 11: ...22 LCD Color Monitor BenQ G2200W 11 4 Disassembly Assembly 4 1 Three angles view ...
Страница 12: ...22 LCD Color Monitor BenQ G2200W 12 4 2 Exploded View ...
Страница 18: ...22 LCD Color Monitor BenQ G2200W 18 4 Until appears the follow Figure writer completed ...