Release
1.1
Technical Documentation
10/2005
TD_Repair_L2.5L_SL75_R1.1.pdf
Page 10 of 11
9 Camera Connector Problems
Fault Symptoms
Customer: GRT:
Camera malfunction
Tbd.
Camera connector Problems
Watch for oxidation and
damaged pads of the
camera connector
caused by customer
SCRAP
- has to be send
separately to WSC
not
okay
okay
Check the status of the
camera connector
visually
Use the resistor test
function of a multimeter
to check connection
between spring
contacts and soldering
contacts.
The value must be ~0
Ω
Exchange
camera
connector
Continue with
higher repair level
okay
not
okay
not
okay
- check for twisted or
bent contacts
- check for dry joints
Back to customer
without repair
Connector CAMERA
Use hot air blower to remove defective component. Avoid excessive heat! Watch surrounding
components! Resolder new component afterwards.
E-commerce order number: L50634-Z97-C379
E-commerce order name:
CONNECTOR CAMERA-SOCKET
Soldering temperature:
~ 360°C TIP Temp.
IRIS Diagnose Code:
BA000 Accessories / Camera
10 Main keypad illumination Problems
Company Confidential
2005©BenQ