background image

Bennett T140 Operation, Service, & Parts Manual

 

Parts

 

25 

TYPE 140 PUMPING UNIT PARTS LIST  

Refer to the Type 140 assembly on the previous page for reference number locations. 

Note

: Not all parts are shown. If the part is not 

included in this list then it is not available for purchase through Bennett Pump Company.

 

Item 

Part No. 

Description 

Comment 

110359 

Housing, Air Valve Float Assembly 

 

108737 

Gasket Housing Air Valve Sub Asm 

 

110360 

Needle Air Valve T140 

 

108734 

Float Assembly Air Vent 

 

111694 

Label Serial Number 

 

A479902 

Screw HEX HD Cap 

M8-1.25 x 25mm 

10 

111058 

Cover, Atmospheric Chamber 

 

11 

111059 

Gasket – Atmospheric Cover 

 

12 

A480101 

Screw-PAN HD MACH 

M6 – 1x 20mm 

14 

111788 

O-Ring 

#017 1/16 x 11/16 x 13/16 

15 

109892 

Atmospheric Float Assembly 

 

16 

A480101 

Screw-PAN HD MACH 

M6 – 1x 20mm 

17 

111741 

Air Separator Body 

 

18 

111047 

Gasket, Inlet Separator 

 

19 

111049 

Gasket – Round, Outlet Separator 

 

20 

111048 

Gasket, Outlet Separator 

 

22 

111046 

Tube – Air Separator 

OIML 

23 

111636 

Piston T140 OIML Air Separator 

OIML 

24 

108725 

Spring Compression  

8mm x 30mm 

25 

108728 

Separator Air Tube Endcap T75 Brass 

OIML 

26 

110430 

PIPE PLUG HEX SOCKET FLUSH 1/4" NPT 

¼ - 18 NPT 

27 

111034 

Cover, Control Valve 

 

28 

111033 

Gasket Control Valve 

 

29 

J325201 

Spring Control Valve Short 

 

30 

111026 

Control Valve Assembly 

 

32 

111032 

O-Ring Control Valve, T140 PU 

 

33 

111004 

Pump Body 

 

34 

N160301 

Filter Stop Insert 

 

35 

111055 

STRAINER ASM 70 MICRON/200 MESH T140 

 

36 

N905001 

Filter Spring 

 

37 

111056 

Gasket Cover Filter T140 PU 

 

38 

111057 

Filter Cover 

 

39 

109668 

Screw – Air Test Valve 

 

40 

109666 

Adapter – Air Test Valve 

 

41 

111043 

NUT CAP ADJ BYPASS T140 PU 

 

42 

111042 

SCREW ADJ BYPASS T140 PU 

 

43 

A507901 

Gasket Adjustable Bypass Screw 

 

44 

111041 

COVER ADJ BYPASS, T140 PU 

 

45 

111040 

GASKET BYPASS VALVE, T140 PU 

 

46 

111035 

Bypass Valve Assembly T140 PU 

 

47 

111647 

Pipe Plug – 1 ½” NPT 

 

48 

111053 

O-Ring Check Valve 

 

62 

111054 

RETAINING RING CHECK VALVE T140 PU 

 

63 

111052 

Check Valve Assembly 

 

64 

A479903 

SCREW HEX HD CAP M8-1.25 x 16mm 8.8 

 

65 

A000301 

WASHER/LOCK ID .319 & OD .575 x .056 THK 

M8 – 1.25 x 20mm 

66 

111025 

WASHER, PULLEY, T140 PU 

 

67 

111024 

Pulley **See Text 

 

70 

111021 

Bearing Retainer 

 

 

 

Содержание 111103

Страница 1: ...2272 Rev H 10 26 18 Introduction Operation Troubleshooting Parts Only Trained Personnel May Work on This Equipment READ THIS MANUAL This manual has important information for safe installation and oper...

Страница 2: ...ite www bennettpump com For new manuals visit our web page at www bennettpump com IMPORTANT Examine the shipment immediately upon arrival to make certain there has been no damage or loss in transit Be...

Страница 3: ...ensions 5 Inlet Mounting Dimensions 7 OPERATION 10 Flow of Liquid Through Pumping Unit AIr Eliminator and Meter 10 Float and Air Separator 11 Adjustable Bypass Valve 11 Control Valve 11 TROUBLESHOOTIN...

Страница 4: ...Bennett T140 Operation Service Parts Manual Table of Contents ii Page Intentionally Left Blank...

Страница 5: ...ubmerged pump before working on it Maintenance repairs must be done by authorized personnel only Warranty work may only be performed by Bennett certified technicians To prevent electric shock keep the...

Страница 6: ...PI 2003 Protection Against Ignitions Arising Out of Stray Lightning and Stray Currents International Fire Code 2000 Edition NFPA 30 Flammable and Combustible Liquids Standard NFPA 30A Motor Fuel Dispe...

Страница 7: ...or assembly Number of blades Size With these improvements combined we are able to produce the increased flow rate yet keep the functions offered by the T75 pumping unit Filtering Pumping Air eliminati...

Страница 8: ...t Flanged Adapter with Gasket Part 111503 PRODUCT SPECIFICATIONS CAUTION OPERATING THE REMOTE DISPENSER OR SUCTION PUMP AT VOLTAGES AT OR ABOVE THE REQUIRED 120 240VAC IS NOT RECOMMENDED FAILURE OR DA...

Страница 9: ...5 20 25 30 35 40 45 10 3 16 0 21 8 29 0 35 8 39 3 41 6 44 2 46 0 46 8 47 4 50 8 Motor HP GPM PSIG 100 mm Stator T140 Max By Pass Setting 765 RPM 2 Diesel Fuel GPM HP 0 4 0 6 0 8 1 0 1 2 1 4 1 6 1 8 0...

Страница 10: ...nual Product Introduction 5 EXTERIOR DIMENSIONS FLANGED FRONT VIEW 2 84 68 mm FLANGED OUTLET BOTTOM VIEW 11 57 294 0 mm FIGURE 4 FLANGED OUTLET TOP VIEW FLANGED OUTLET BACK VIEW 9 01 229 mm FLANGED OU...

Страница 11: ...n Service Parts Manual Product Introduction 6 1 63 40mm TUBE OUTLET BOTTOM VIEW 11 49 291 9 mm TUBE FRONT VIEW 9 01 229 mm 2 84 68 mm 12 7 323 1 mm TUBE OUTLET BACK VIEW TUBE OUTLET TOP VIEW TUBE OUTL...

Страница 12: ...NTING DIMENSIONS When installing units that contain a high alcohol product e g E100 Confirm that the plumbing is designed to handle the selected petroleum product For multi hose units piping must alig...

Страница 13: ...Bennett T140 Operation Service Parts Manual Product Introduction 8 FLANGED AND TUBULAR SIDE INLET SIDE INLET CENTER FIGURE 7...

Страница 14: ...Bennett T140 Operation Service Parts Manual Product Introduction 9 Page Intentionally Left Blank...

Страница 15: ...in parenthesis The fuel is drawn from the storage tank through the Strainer Screen or Filter 1 The Rotary Vane Pumping Unit 2 pressurizes the fluid Fuel enters the Centrifugal Air Separator Assembly 3...

Страница 16: ...dispensed The adjustable bypass assembly includes the valve spring and guide as well as a cover adjustment screw and brass cap Refer to Figure 10 CONTROL VALVE The type 140 pumping unit uses a contro...

Страница 17: ...mercury is required to overcome the restriction of an angle check foot valve or vertical check valve 3 An inch of mercury is required to overcome the restriction of 60 feet of piping 4 Add the readin...

Страница 18: ...ers are marked for easy identification 1 Remove the pipe plug in the center of the control valve cover Covers are marked for easy identification 2 Install the pressure gauge 3 Start the pump and open...

Страница 19: ...Bennett T140 Operation Service Parts Manual Troubleshooting 14 Figure 15...

Страница 20: ...Bennett T140 Operation Service Parts Manual Troubleshooting 15 Figure 16...

Страница 21: ...heck for a faulty foot valve in the storage tank or a faulty check valve in the suction line The suction line is leaking Start the pump and open the nozzle If bursts of air are felt while holding a fi...

Страница 22: ...causes of the problem and the solution Cause Solution The power is off Check the circuit breaker in the station The motor is defective Disconnect the power supply Inspect the motor for loose connecti...

Страница 23: ...orm at 60 F of today s product is approximately 10 PSI See Figure 19 The difference between Atmospheric Pressure and Vapor Pressure is known as the Working Pressure The Working Pressure is all that th...

Страница 24: ...st create to pump the product A It takes 1 inch of vacuum to lift gas 1 5 feet vertically To determine the inches of vacuum required to lift the gas in a system follow this procedure 1 Measure the dis...

Страница 25: ...TAL 8 of Suction With 9 4 of suction to work with and only 8 of vacuum required conditions are normal and the pump delivers product without vapor locking Remember this condition exits when the product...

Страница 26: ...er temperatures there are only 5 4 inches of vacuum to lift the product THE RESULT IS VAPOR LOCK As we have explained the pump plays a very small part in vapor lock situations Installation the amount...

Страница 27: ...part number description and quantity required 2 Rebuilt parts must be used for warranty claims Rebuilt exchange program parts are identified by a RB prefix to the part number Note Many electronic circ...

Страница 28: ...92 PU T140 Bennett High Flow w Inlet Adapter 115225 PU T140 OIML Version 118496 PU T140 High Flow Side Inlet 122996 PU T140 Bennett High Flow w Serial Label T140 PUMPING UNIT HIGH FLOW W INLET ADAPTER...

Страница 29: ...eration Service Parts Manual Parts 24 T140 PUMPING UNIT ASSEMBLY Refer to the Type 140 Parts Lists on the following pages for part numbers description and comments Note Item numbers are not listed in...

Страница 30: ...23 111636 Piston T140 OIML Air Separator OIML 24 108725 Spring Compression 8mm x 30mm 25 108728 Separator Air Tube Endcap T75 Brass OIML 26 110430 PIPE PLUG HEX SOCKET FLUSH 1 4 NPT 18 NPT 27 111034 C...

Страница 31: ...ly 100mm Stator 82 115715 Needle Bearing 100mm Stator 83 115718 100mm Stator T140 KITS The dispenser quantity is recommended and may vary based on the options ordered for your dispenser INLET CHECK VA...

Страница 32: ...uctions Kit T140 Field Rebuild 1 111011 Throw Out Ring T140 PU 2 111012 Rotor and Shaft Assembly 1 1 111015 Blade 8 A199501 Woodruff Key 406 1 114992 Rotor Cover Lip Seal 1 114991 Stator Lip Seal 1 11...

Страница 33: ...g 100mm 1 114991 Lip Seal Stator 1 114992 Lip Seal German Rotor Cover 1 113658 Plug For Service T140 1 PUMPING ELEMENT 8 BLADE FIELD REBUILD 100MM P N 115736 Part No Description Qty 115737 Instruction...

Страница 34: ...Bennett T140 Operation Service Parts Manual Parts 29 Page Intentionally Left Blank...

Страница 35: ...Bennett T140 Operation Service Parts Manual 30 Page Intentionally Left Blank...

Страница 36: ...Bennett 1218 E Pontaluna Road Spring Lake MI 49456 USA 800 235 7618 Outside USA 231 798 1310 sales bennettpump com www bennettpump com...