Step 6
Install Hydraulic Power Unit (HPU) in a convenient location with
a dry environment.
Important: The HPU must be mounted
in a dry enough location to avoid submersion and
drenching.
Allow space above the HPU so that it may be slid
into its mounting bracket (about 3"). Lay out upper holes on
HPU mounting bracket 4 5/8" apart and start #10 x 1" screws
using 5/32" pilot holes. Then drill 5/32" pilot holes for lower
screws and mounting bracket. Slide HPU into bracket.
Step 7
Inside the transom, apply Teflon tape on male threads of pipe
nipples and tighten 90 degree brass elbows to pipe nipples.
While tightening elbow, hold pipe nipple with vise grips
to prevent stripping.
Step 8
Run hydraulic tubing from actuators at transom to HPU
(See Figure 4)
and cut to length.
Note: Make port and
starboard lengths as equal as possible.
Step 9
Insert tubing through the nut with ferrule at 90 degree elbow. Push until it bottoms in
the fitting. While continuing to bottom the tubing in the fitting, tighten nut “finger
tight”, then one full turn with a 1/2" wrench . . . NO MORE.
Step 10
To connect tubing to Hydraulic Power Units, insert tubing through the nut with
ferrule fitting and push into the pump-face fitting until it bottoms. While continuing
to bottom the tubing in the fitting, tighten nut “finger tight”, then one full turn with a
1/2" wrench … no more. Use tube bending clips at desired 90 degree bends in tubing to prevent kinking.
Step 11
Connect HPU ground wire to the the vessel’s negative ground system.
Step 12
Wire control and electrical system per separate instruction sheet.
Step 13
Remove plug from filler stack located at the front left corner of the reservoir. Fill reservoir to “Full Line” using any type
automatic transmission fluid (ATF)
.
Step 14
Using the control, hold the “Bow Down” position for 15 seconds, then “Bow Up” for 15-20 seconds. Repeat 3 times.
This will purge air from the system.
Step 15
Place both tabs in the “full down” position and check all hydraulic connections for leaks. Bring the tabs to the full up position
and check fluid level. Add ATF if necessary
.
Figure 4
Tighten Nut with 1/2" Wrench One Full Turn Past Finger
Tight - NO MORE
Push Tubing to Bottom of Fitting While Tightening
Содержание SST System
Страница 1: ...Installation Instructions...