18
19
INSTALLATION
INSTALLATION
STEP 1 – REMOVE ALL MOUNTING HARDWARE
For Metrix and Metrix Primus Soap
Dispensers:
Drill a hole in the deck or lavatory according
to the recommended hole size.
Remove the nut, the disk and the gasket from
the base of the soap dispenser body.
RECOMMENDED HOLE SIZE
If your dispenser is supplied with
anti-rotation solution, drill an additional hole
for anti-rotation pin.
For Sintra Soap Dispenser:
Remove the hexagonal nut, disk and washer.
Do not remove the O-ring from the base of
the faucet.
NUT
DISC
WASHER
O-RING
Drill a hole in the deck or lavatory according
to the recommended hole size.
18-25 mm
STEP 2 – INSTALLING THE SOAP DISPENSER
1
For Metrix and Metrix Primus Soap
Dispensers:
Place the soap dispenser body along with
the bottom ring into the hole in the deck
or lavatory.
Slide the gasket, disk and nut over the
soap dispenser body nipple and secure it.
For Sintra Soap Dispenser:
Slide the washer, disk and hexagonal
nut over the flexible hose and secure
the faucet into place.
NUT
DISC
WASHER
O-RING
2
Fix the bottle with bottle support to
the desired location.
3
Snap the soap pipe from the
dispenser body into the quick
connection fitting of the pump.
STEP 3 – CONNECTING THE POWER SOURCE
1
Remove the protective sticker
covering the sensor. Keep away from
the sensor range.
2
Connect the pump connector to its
matching connector coming from
the electronic unit. Please note that
since the connector is water proof,
some friction might apply.
O-RING VISIBLE –
NOT CONNECTED PROPERLY
ONLY THE GROOVES ARE VISIBLE –
CONNECTED PROPERLY
SINTRA RECOMMENDED HOLE SIZE