24
25
BATTERY REPLACEMENT
batterY models onlY
low battery Indicator
the perfect time shower panel has an advanced battery level management system
consisting of 2 steps. In the first step, the battery still has enough power to open and
close the solenoid valve, and allows the solenoid valve to open. at the second step
the battery might not have enough power to open and close the solenoid valve.
In this case, the battery level management system does not allow the solenoid valve
to open. Instead of providing an opening and closing pulse, the system provides two
closing pulses.
battery replacement instructions:
1
unscrew the 2 screws at the
bottom of the battery cover
located at the bottom cover of
the panel.
2
pull out the battery cover with the
Ip67 battery box attached on it.
the Ip67 battery box is attached
to the battery cover with a reus-
able Velcro ribbon.
note: If you will not press the indicated area, the previous adjustment will remain.
5) by touching the piezo button the new flow time will be programmed. In adjusting
mode level 1, each touch increases the flow time by 1 second with a maximum of 100
seconds. You will see the led blinking every time that a new step is performed.
6) If you have reached your desired flow time in this level, stop pressing the piezo but-
ton. the led will blink 2 times, 3 times, 4 times and after the 5th time you will exit the
adjusting mode. Your product is now adjusted to the desired flow time.
7) If you need to perform steps in adjusting level 2, wait until you see the indicator light
blinking twice and then, perform the needed quantity of steps (with a maximum of 100
steps of 5 seconds)
8) If you do not need more levels, stop pressing. the indicator light will blink 3 times,
4 times and after 5 times you will exit the adjusting mode. Your product is now adjusted
to the desired flow time.
9) If you need to perform steps in adjusting level 3, wait until you see the indicator light
blinking 3 times and then, perform the needed quantity of steps. (with a maximum of
100 steps of 20 seconds)
10) to leave the adjusting mode wait until the led blinks 4 times and then 5 times. Your
product is now adjusted to the desired flow time.
Warning: In order to avoid enabling the 24 hs. hygiene flush option without intention,
do not touch the piezo button after the led blinks 4 times.
FLOW TIME ADJUSTMENT