Benjamin Heating products WK400 Скачать руководство пользователя страница 7

 

-6- 

POWER FAILURE OPERATION

 

NOTE: 

DO NOT

 operate your appliance, unless your total heating system has been designed and installed 

to operate properly without electricity

.

 

1. 

Remove the blower door and filter. 

2. 

Using a non-combustible material, brace the draft door open (1/4" maximum). 

3. 

Open all warm air registers and dampers. 

4. 

Open the furnace room door & the basement door, to permit gravity air flow circulation. 

5. 

Maintain the fire at 1/2 normal levels. 

6. 

Inspect the fire at frequent intervals to ensure safe operation. 

 

 

FLUE FIRE

 

1. 

Call the Fire Department.  

 

 

 

 

 

 

 

 

 

 

2. 

Prepare to evacuate the house. 

3.

  Shut off the main power switch to the furnace. 

4.  

Diminish the fire in the furnace by closing all combustion air openings. 

5. 

DO NOT remove the flue pipes until the fire is completely out. 

6. 

Have the chimney inspected and repair the flue before using it again. 

 

DO NOT

 STORE FLAMMABLE MATERIALS OR LEAVE PAPER OR RAGS IN THE VICINITY OF 

THE FURNACE  
Burn WOOD only. USE PAPER TO START A FIRE ONLY. 
Remove ash at regular intervals to prevent residue roll out from the fire door. 

DO NOT

 fill the firebox above the smoke baffle at top of fire door frames. 

DO NOT

 use fluids, gasoline, oils or chemicals to start a fire. 

DO  NOT

  BURN  GARBAGE,  tar  products,  gasoline,  plastics,  drift  wood  or  materials  containing  salt  or 

chemicals.  This  is  extremely  dangerous  and  will  void  the  warranty.  Burn  wood  only.  Fuel  storage  must 
conform to local ordinances having jurisdiction. 

 

CLEANING AND MAINTAINING YOUR "WK400"

 

Establish a routine for the storage of fuel, care of the appliance and firing techniques. 
Check daily for creosote build up until experience shows how often cleaning is necessary. 
Be aware that the hotter the fire, the less creosote is deposited. Weekly cleaning may be necessary in mild 
weather even though monthly cleaning may be enough in the coldest months. Have a clearly understood  
plan to handle a chimney fire. Ensure that the heat exchanger, flue pipe and chimney are cleaned at the  
end of the heating season to minimize corrosion in the summer months. 

NOTE:

 

Keep the furnace, vent pipe and chimney clean. This will increase efficiency and reduce the risk of soot  
and creosote fires. 
Solid fuel requires a sufficient supply of air for combustion and combustion air is required above the fuel  
bed (over fire slot at the top of the door). 
Clean and inspect as necessary (at least yearly). 

 

ASHES

 

Ash should be removed before it reaches the bottom of the fire door frame. Sand or ash should be 1 1/2"  
below the bottom of the fire door frame. This will ensure proper air flow thru the fire. Ashes when  
removed  from  the furnace should be placed in  a metal  container with  a tight  fitting lid and immediately 
removed to a safe location. Ashes often contain hot dormant coals. 

   
 
 
 
 
 
 

Содержание WK400

Страница 1: ...must be given to the homeowner Please read the warranty and return the warranty card to initiate coverage We Strongly Recommend The Use Of A Carbon Monoxide Detector When Using Any Product That Consum...

Страница 2: ...el oil combinations and add ons wood burning appliances shall not be connected to a venting system serving an appliance vented by another type of fuel Connect the furnace to an approved solid fuel fac...

Страница 3: ...a of opening is 1 square foot per 100 000 BTU HR total the combined maximum BTU s of the two furnaces for a WK400A ADD ON Where fans are used in the fuel storage area they should be installed so as no...

Страница 4: ...n accordance with page 9 using the controls provided The proper positioning of the controls on the wood unit is shown on page 8 The interconnecting wiring from the primary furnace to the wood furnace...

Страница 5: ...have stabilized This will take at least hour Read the two temperatures thus obtained and not the difference TS TR see page 8 This difference should not exceed 85 degrees F 29 C Complete the installati...

Страница 6: ...t provided 10 If properly mounted the blower will make contact with foil faced insulation 1 8 all around 11 Use insulation obtained from cutout for blower gasket Do NOT use a manual smoke damper with...

Страница 7: ...ls containing salt or chemicals This is extremely dangerous and will void the warranty Burn wood only Fuel storage must conform to local ordinances having jurisdiction CLEANING AND MAINTAINING YOUR WK...

Страница 8: ...eplace if necessary 6 Replace the covers in reverse order BLOWER and MOTOR Twice yearly oil the blower motor bearings with 4 drops of 20 SAE oil Twice yearly oil the blower motor bearings with 2 drops...

Страница 9: ...TYPICAL ADD ON INSTALLATION...

Страница 10: ...9...

Страница 11: ...10 RECOMMENDED WIRE ROUTING WHEN USED AS A FREE STANDING UNIT NOTE THE BLOWER BOX CAN BE MOUNTED ON EITHER SIDE...

Страница 12: ...11...

Страница 13: ...12 Wood Furnace Operating Cycle...

Страница 14: ...13 Notes...

Страница 15: ...14 Notes...

Страница 16: ...15 A division of W R BENJAMIN PRODUCTS LIMITED P O Box 2079 Springhill Nova Scotia Canada B0M 1X0 Phone 902 597 3796 Fax 902 597 3797 E mail info benjaminheating com Web site www benjaminheating com...