WAKE_UP 

 

 

class: 0x71 COMMAND_CLASS_ALARM 

The Alarm Command Class is used to receive alarm notifications and security related events from other 
devices.

 

class: 0x85 COMMAND_CLASS_ASSOCIATION  

The Association Command Class is used to configure devices to send notifications to the Internet Gateway.

 

class: 0x20 COMMAND_CLASS_BASIC  

The Basic Command Class is used as a fallback mechanism when trying to communicate with devices that do 
not support any of the Command Classes that are controlled by the Internet Gateway.

 

class: 0x80 COMMAND_CLASS_BATTERY  

The Battery Command Class is used to obtain battery information from devices.

 

class: 0x70 COMMAND_CLASS_CONFIGURATION  

The Configuration Command Class is used to configure device-specific settings. Refer to the manuals of the 
device in question for more information.

 

class: 0x72 COMMAND_CLASS_MANUFACTURER_SPECIFIC  

The Manufacturer Specific Command Class is used to identify the manufacturer and device type of a device. 
This information is used to identify and configure the device in the benext Graphical Web-interface.

 

class: 0x32 COMMAND_CLASS_METER  

The Meter Command Class is used to request the value of a Z-Wave enabled electric, gas, water or other kind 
of meter.

 

class: 0x8F COMMAND_CLASS_MULTI_CMD  

The Multi Command Class can be used for sending multiple commands at the same time, increasing Z-Wave 
network performance. 

class: 0x8E COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION  

The Association Command Class is used to configure devices to send notifications to the Internet Gateway. 
This Command Class can be used for devices that consist of multiple sub-devices. See also the Multi Channel 
Command Class.

 

class: 0x60 COMMAND_CLASS_MULTI_CHANNEL  

The Multi Channel Command Class is used to support devices that consist of multiple sub-devices, for instance 
a quad-socket power switch. 

class: 0x73 COMMAND_CLASS_POWERLEVEL  

The Powerlevel Command Class is used to check the connection quality between two Z–Wave devices. 

class: 0x75 COMMAND_CLASS_PROTECTION  

The Protection Command Class can be used to set a device in ‘protected mode’. Protected mode can be seen 
as some kind of child-lock, disabling for example any buttons on the device. 

Содержание iHOME

Страница 1: ...Gateway is booted the indicator light will turn orange B Connecting to the benext server After booting the Internet Gateway tries to connect to the benext server While the Internet Gateway is trying t...

Страница 2: ...eturns to normal operation mode the Internet Gateway has other devices included in its network Exclude them first using the benext Graphical Web interface 5 After a few seconds the indicator light sho...

Страница 3: ...es has a secure connection to the backoffice e g benext and runs with unique rules for every lifestyle which the end consumer had configured Also the complete firmware of the Z Wave module and micropr...

Страница 4: ...ates standalone where the internet connection and benext is not actually needed anymore However one is advised to keep the connection active at all times to receive updates when needed and to have goo...

Страница 5: ...GRAPHICAL_LOCATION class 0x9A COMMAND_CLASS_IP_CONFIGURATION class 0x72 COMMAND_CLASS_MANUFACTURER_SPECIFIC class 0x8F COMMAND_CLASS_MULTI_CMD class 0x73 COMMAND_CLASS_POWERLEVEL class 0x92 COMMAND_CL...

Страница 6: ...on configuration class 0x8C COMMAND_CLASS_GEOGRAPHICAL_LOCATION The Geographic Location Command Class can be used to set or request the world wide position of the device class 0x9A COMMAND_CLASS_IP_C...

Страница 7: ...ion of the device Controlling Command Classes Command class Version Supports Controls ALARM 2 X X ASSOCIATION 1 X BASIC 1 X BATTERY 1 X CENTRAL_SCENE 1 X CLIMATE_CONTROL_SCHEDULE 1 X CLOCK 1 X CONFIGU...

Страница 8: ...a device This information is used to identify and configure the device in the benext Graphical Web interface class 0x32 COMMAND_CLASS_METER The Meter Command Class is used to request the value of a Z...

Страница 9: ...at exactly the same time class 0x25 COMMAND_CLASS_SWITCH_BINARY The Binary Switch Command Class can be used to control devices that can be turned on or off for example a power switch class 0x26 COMMAN...

Страница 10: ...y A 1 You can use www benext eu website to connect with the Internet Gateway and control all devices Q How to connect to a Smart Meter A Always use the supplied P1 cable plug the small RJ12 plug insid...

Отзывы: