COMMUNICATION PROTOCOL
REV: 13/05/2022
·
©2022 Benewake
(Beijing) Co., Ltd. |
| All rights reserved
BP-UM-22 A03
6
3
COMMUNICATION PROTOCOL
There are two communication interfaces available. The hardware of RS485 and CAN is
different. The interface can not be switched by command.
3.1
RS-485 Communication Protocol
3.1.1
Communication protocol
Modbus protocol is the default setting for RS-485 interface. The parameter is shown in
Table 3-1. The default value of baud rate and slave ID is 115200 and 0x01.
Table 3-1 RS-485 Communication protocol of TF02-i
Characteristics
Values
Communication interface
RS-485
Baud rate
115200
Data bit
8
Stop bit
1
Parity
None
Note
The following baud rates are supported: 9600
,
14400
,
19200
,
38400
,
43000
,
57600
,
768000
,
115200(default)
,
128000
,
230400
,
256000. It is not
recommended to use a baud rate above 115200 for communication
because of communication stability.
3.1.2
Parameter configuration description of Modbus protocol
3.1.2.1
Description of data frame
When Modbus protocol of TF02-i is enabled, the Modbus command format of reading
distance is shown in Table 3-2.
Table 3-2 The command format of reading distance
Addr.
Function code Register Addr. Register Value CRC_Low CRC_High
01(Default)
03
00
00
00
01
xx
xx
The response data frame format is shown in Table 3-3.
Table 3-3 The response date frame format
Addr.
Function code Length Dist_High Dist_Low CRC_Low CRC_High
01(Default)
03
02
XX
XX
xx
xx