Benetech GM3120 Скачать руководство пользователя страница 2

1

.

Long

 

press

 

power

 

to

 

turn

 

it

 

on

.

After

 

full

 

screen

 

display

,

the current

 

electric

 

field

 

and

 

magnetic

 

field

 

value

 

will

 

be

 

displayed

,

press

 

power

 

to

 

turn

 

the

 

backlight

 

on

.

The

 

screen

 

will

 

display

“     ”. 

Press

 

it

 

again

 

to

 

disable

 

the

 

backlight

.

If

 

there

 

is

 

no

 

key operation

,

the

 

backlight

 

will

 

turn

 

off

 

automatically

 

after

 

30 seconds

.

Long

 

press

 

power

 

to

 

shut

 

it

 

down

.

If

 

there

 

is

 

no

 

key operation

the

 

instrument

 

will

 

shut

 

down

 

automatically

 

after

 

minutes

.

Note

:

As

 

there

 

may

 

be

 

disturbance

 

of

 

electromagnetic

 

field

 

in the

 

environment

,

when

 

starting

 

up

,

the

 

instrument

 

may

 

give

 

a small

 

reading

.

It

 

is

 

a

 

normal

 

phenomenon

.

2

.

Hold

 

the

 

instrument

 

with

 

hand

 

to

 

make

 

the

 

inductive

 

zone

 

at front

 

end

 

get

 

closer

 

to

 

the

 

electromagnetic

 

radiation

 

source

 

to

 

be tested

 

slowly

.

If

 

the

 

actual

 

radiation

 

value

 

is

 

within

 

the

 

technical index

 

of

 

the

 

instrument

,

there

 

will

 

be

 

a

 

value

 

displayed;if

 

the instrument

 

has

 

no

 

reading

it

 

indicates

 

that

 

the

 

electromagnetic radiation

 

value

 

of

 

the

 

radiation

 

source

 

is

 

smaller

 

than

 

the

minimum

 

reading

 

of

 

the

 

instrument

,

namely 1V

/

m

 

or

 

0

.

01

μ

T

.

Note

:

Distance

 

measuring

 

shall

 

be

 

made

 

for

 

high-voltage facilities

.

Remember

:

stay

 

safe

.

3

.

During

 

measurement

,

press

HOLD

to

 

lock

 

the

 

instrument reading

.

The

“     ”

will

 

be

 

displayed

 

on

 

the

 

screen

.

In

 

case

 

of unlocking

,

press

“     ”

again

.

This

 

instrument

 

will

 

produce

 

a beep

 

by

 

default

 

after

 

turning

 

on

 

and

“  ”

will

 

be

 

displayed

 

on the

 

screen

.

Long

 

press

 

the

BEEP

to

 

turn

 

on

 

or

 

off

 

the

 

beep

.

4

.

By

 

pressing

AVG/VPP

during

 

measurement

 

under unlocking

 

state

,

you

 

can

 

switch

 

between

 

the

 

average

 

and

 

the

 

peak value

.

5

.

If

 

the

 

figure

 

displayed

 

is

 

unclear

 

or

 

the

 

figure

 

flickers

 

or

 

the figure

 

cannot

 

be

 

cleared

,

it

 

indicates

 

that

 

the

 

battery

 

runs

 

out

 

of power

Please

 

change

 

the

 

battery

 

in

 

time

.

       

      This

 

radiation

 

survey

 

meter

 

has

 

the

 

following

 

features

   One instrument with two uses,It can test the 
electric field and

 

the

 

magnetic

 

field

 

radiation

 

at

 

the

 

same

 

time

;

   Sound-light alarm,when the test result 
exceeds the safe value,the

 

instrument

 

will

 

alarm

 

automatically

;

   

Data locking,one-key lock of the radiation value;

   

LCD graphic display of the radiation value trend;

   Radiation assessment,remind you whether the 
radiation value is

 

safe

 

or

 

not

;

   Fashionable design,easy on-hand operation,it 
is easy to move or

 

make

 

field

 

measurement

.

   Electromagnetic radiation monitoring

:

House and apartment,office,outdoor and 
industrial site;
   Electromagnetic radiation test

:

Mobile phone, computer, TV set, refrigerator and 
high voltage cable radiation test;
 

  

Radiation protection product test

:

Test effects of radiation-proof clothes, radiation-
proof film and other prevention articles.

X-ray radiation index

:

★★★★★

Electric

 

hair

 

drier

 

radiation

 

index

:

★★★★★

Electric

 

blanket

 

radiation

 

index

:

★★★★

Microwave

 

oven

 

radiation

 

index

:

★★★★

Computer

 

monitor

 

and

 

host

 

radiation

 

index

:

★★★

Mobile

 

phone

 

radiation

 

index

:

★★

TV

 

set

 

radiation

 

index

:

★★

Keyboard

 

and

 

mouse

 

radiation

 

index

:

Copying

 

machine

 

and

 

printer

 

radiation

 

index

:

Security

 

check

 

radiation

 

index

:

Electromagnetic

 

Radiation

 

Tester

AVG
VPP

HOLD
BEEP

Version

GM3120-EN-00

Model: 

GM3120

Electromagnetic

 

Radiation

 

Tester

Instruction manual

      Radiation survey meter can test electric field 
radiation and magnetic field emission to reach 
the optimal test result. It is used to test and learn 
electromagnetic radiation situation indoor and 
outdoor. It is equipped with a built-in 
electromagnetic radiation sensor, which can 
display the radiation value on LCD digital display 
after processing by the control micro-chip. You 
can make reasonable processing or taking 
effective prevention measures toward the 
electromagnetic radiation according to the test 
result.
      Influence and harms of electromagnetic 
radiation on human body:
1.Being one of the causes of leukemia for 
children;
2.Can cause cancer and accelerate proliferation 
of cancer cells;
3.Can cause direct harm to human genital 
system, nervous system and immune system;
4.Can cause mental disabilities of children and 
diminution of vision, affect tissue development 
and skeletal development of children;
5.Can cause diminution of hematopoietic 
function of livers and even cause amotio retinae;
6.Being one of the main causes of cardiovascular 
disease and diabetes;
7.Having bad influence on human visual system.
      Moreover, strong electromagnetic radiation 
may influence and destroy original bioelectric 
current and biomagnetic field in human body and 
cause abnormity of the original electromagnetic 
field in human body. The elderly, children and the 
pregnant are susceptible to electromagnetic 
radiation.
      Artificial electromagnetic radiation sources 
include all kinds of electric appliances and 
devices. By fair use of household appliances and 
taking reasonable precautious measures, 
electromagnetic radiation can be effectively 
prevented and reduced.

II

Functions

 

and

 

features

VII

Technical

 

parameters

I

Introduction

III

Range

 

of

 

application

VI

Radiation

 

indexes

2

1

3

5

6

V

Operating

 

instructions

4

VI

LCD

 

display

 

and

 

key

 

function

1

LCD full-screen display: see the following figure.

2. Names of components: see the following figure.

A. Inductive zone at front end 

B.LCD display 

C. Average/peak value 

Unit

Precision

Range

Alarm threshold value

Reading display

Testing bandwidth

Sampling time

Test mode

Over range indication

Operating temperature

Operation humidity

Operating voltage

Power supply

Size

Weight

Electric field

V

/

m

1V

/

m

1V

/

m

-

1999V/m

40V

/

m

Magnetic field

μ

T

0

.

01

μ

T

0

.

01

μ

T

-

19

.

99

μ

T

0

.

4

μ

T

3-1/2-digit LCD

About 0.4 seconds

Bimodule synchronous test

LCD displays “1”

relative

 

humidity

80

%

battery

5Hz—3500MHz

0

~50

9V

6F22  9V

63

.

6

*

31

*

125

.

8mm

146g

B

A

C

D

E

F

Special declaration:
Our company reserves the right to modify the 
product design and the instruction. We will not 
give further notice for any changes!

D. Data locking/beep

E. Power

F. Battery door

Reference standards:
GB8702-1988 Regulations for Electromagnetic 
Radiation Protection
HJ/T10.3-1996 Environmental Impact Assessment 
Methods and standards on Electromagnetic Radiation
GB9175-88 Hygienic Standard for Environmental 
Electromagnetic Waves

Отзывы: