background image

E. LCD Display (Figure 3) 

1). Level range.
2). Instantaneous sound pressure level.
3). Low battery mark.
4). Maximum value is held during measuring.
5). Measuring value.
6). Measurement Unit.
7). Frequency weighting A/C.
8). Level range Bar graph.
9). Rang over.
10). Slow time weighting.
11). Fast time weighting.

12). Range under.

F. Pre-Operations:

1. Open the battery door and install 4pieces  battery

into the battery compartment.

2. Cover the battery door.

3. When battery voltage drops below the operating 

voltage, mark “         “ appears, Please  replaced 
with a new 9V battery. (Figure 4)

4. When the DC adapter is used, insert plug (3.5 

)

of the adapter into the DC 6V connector

G. Operation 

H. Caution

I. Specification

Measuring range

30dBA-130dBA, 35dBC - 130dBC

Accuracy

±1.5 dB ( 94 dB@1KHz )

Frequency range

31.5Hz – 8.5KHz 

Linearity range

50dB/100dB

Frequency weighting

A/C

Digital Display

4 digits

Resolution

0.1 dB

Sample rate

2Times/Second

Bar graph

50 dB scale at 1 dB step for monitoring
current sound pressure level display Sample 

rate: 20Times/Second

Over Indication

OVER/UNDER

AC Output

0.707 Vrms at FS outputimpendance

approx 600 ohm

DC Output

10 mV / dB output impedance approx 100

Time Weight

FAST/SLOW

Microphone

½ Inch Electric Condenser Microphone 

Max Hold

MAX

Power supply

4*AA 1.5V alkaline cells or DC 6V

100mA (Maximum DC 9V)

Battery Life

About 30hours (Alkaline Battery)

Self Calibration Time

3Second

Operating Condition

0~40 10~80%RH

Storage condition:

-10~60 10~70%RH

Weight

308g (including battery)

Dimension

256x70x35mm

MADE

 

IN

 

CHINA

(Page 5)

(Page 6)

(Page 4)

1. Turn on the unit
2. Standard the desired measuring range until the LCD  

not display “ 

Under

” or “ 

Over

3. If measure general noise sound level, please 

selected dBA.

4. If the sound source consists of the shot brusts of only 

catching sound peak, set response to FAST. 
To measure average sound level, use the slow time 
weight.

5. When MAX mode is chosen. The instrument

captures and hold the maximum noise level.

1. Do not operate the unit at high temperature and 

Humidity environment.

2. Please take out battery from unit if not in use

for any extended period of time.

3. Once using the unit in the presence of wind,

it is a must to mount the windscreen to not
pick up undesired signals.

4. Below 200 feet in Height, Humidity 80%RH,

Temperature from 0 to 40 .

8. AC output terminal: 0.707 Vrms Corresponding

to each range step.

9. DC out put terminal: output 10 mV/ dB
10. Calibration control
11. External DC 6V power supply terminal.
12. Tripod 

mounting

screw.

13. Windscreen.

Figure 4