20
GO TO MODULATOR, INSPECT WIRING CONNECTOR.
DISCONNECT CONNECTOR AND TEST RESISTANCE
BETWEEN PINS ON MODULATOR, RESISTANCE VALUES
FOR BENDIX
®
M-21
™
MODULATOR (FIGURE 5).
HOLD TO SOURCE:
READ 3.5 TO 5 OHMS
EXHAUST TO SOURCE:
READ 3.5 TO 5 OHMS
EXHAUST TO HOLD:
READ 7 TO 10 OHMS
TEST EACH PIN TO VEHICLE GROUND AND NOTE NO
CONTINUITY.
RECONNECT CONNECTOR TO MODULATOR.
TURN IGNITION ON AND PASS MAGNET OVER
RESET ON EC-15
™
CONTROLLER. NOTE
REACTION OF RED LEDS.
ARE ANY RED LED’S
ILLUMINATED?
RESISTANCE READINGS
CORRECT?
START HERE FROM
SECTION VI A
REPLACE THE MODULATOR
NO
YES
GO TO SECTION IV “INSPECTION FOR
ILLUMINATED LEDS” AND RETEST.
REPAIR OR REPLACE
MODULATOR WIRE HARNESS.
SAME RED LED’S
ILLUMINATED?
REPEAT THE “INITIAL
START-UP PROCEDURE”
TROUBLESHOOTING
SECTION VI B - TESTING THE MODULATOR
NO
YES
NO
YES