Manual
EN
RFID114_D00328_00_M_XXEN/04.2018
For use in combination with charge controllers used in electric vehicle charging stations, wall boxes or street light charging points
RFID114
Страница 1: ...Manual EN RFID114_D00328_00_M_XXEN 04 2018 For use in combination with charge controllers used in electric vehicle charging stations wall boxes or street light charging points RFID114...
Страница 2: ...rmany Londorfer Str 65 35305 Gr nberg Germany Tel 49 6401 807 0 Fax 49 6401 807 259 E mail info bender de www bender de Bender GmbH Co KG All rights reserved Reprinting only with permission of the pub...
Страница 3: ...t service and support 5 1 3 Delivery conditions 6 1 4 Inspection transport and storage 6 1 5 Disposal 6 1 6 Intended use 6 2 RFID module 8 2 1 Dimensions for mounting 9 2 2 Operation 10 3 Technical da...
Страница 4: ...Table of Contents 4 RFID114_D00328_00_M_XXEN 04 2018...
Страница 5: ...shooting Telephone 49 6401 807 760 Fax 49 6401 807 259 In Germany only 0700BenderHelp telephone and fax E mail support bender service de Available from 7 00 a m to 8 00 p m 365 days a year CET UTC 1 1...
Страница 6: ...se This manual provides a description of an RFID module which may only be used in combination with Bender charge controllers The charge controller is designed for use in electric vehicle EV charging s...
Страница 7: ...ust be mounted at a distance of at least 20 mm from any significant metal surface or metal parts to ensure an optimum reading performance of the RFID module CAUTION Electrostatic discharge ESD may cau...
Страница 8: ...NFC communication means on this frequency Currently only passive tags with a UID are read Further functionality is possible upon re quest 2 1 Dimensions for mounting All dimensions in mm The provided...
Страница 9: ...00_M_XXEN 04 2018 2 2 Operation The charging process is initiated by holding a valid RFID card close to the an tenna of the RFID module The charging process can be finished by holding the RFID card cl...
Страница 10: ...ltage 800 V Rated insulation voltage 12 5 V Altitude 2000 m AMSL Nominal voltage nominal current Nominal voltage DC 3 3 V Nominal voltage tolerance 5 Nominal current 80 mA Frequency Radio frequency 13...
Страница 11: ...IEC 60721 Stationary use IEC 60721 3 3 3M4 Transport IEC 60721 3 2 2M2 Long term storage IEC 60721 3 1 1M3 Connection Connection to charge controller via RJ45 cable Maximum cable length 3 m Other Degr...
Страница 12: ...1 2006 A11 2009 A1 2010 A12 2011 AC 2011 A2 2013 EN 61851 1 2011 EN 61851 22 2002 ETSI EN 301 489 1 V2 1 1 2017 ETSI EN 301 489 3 V2 1 1 Final Draft 2017 EN 300 330 V2 1 1 2017 Subject to change The s...
Страница 13: ...ives Richtlinien 2011 65 EU RoHS Richtlinie RoHS directive Directives 2014 53 EU RED Richtlinie RED directive Zur Beurteilung der Konformit t wurden folgende Normen herangezogen The assessment of this...
Страница 14: ...6401 807 0 Fax 49 6401 807 259 E Mail info bender de www bender de Produktgruppe Art Nr Ger tebezeichnung Anlage Typenliste der EG Konformit tserkl rung RFID11x Annex Typelist of EC declaration RFID11...