![Bender RCMB101 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/bender/rcmb101/rcmb101_operating-manual_2731743018.webp)
Installation and connection
18
3.3 Example applications
3.3.1
The circuit-breaker is controlled by the charging control electronics and the
switching output X12
The switching output X12 uses the circuit-breaker as a signalling device which is controlled by the
charging control electronics software.
The switching output X12 and the analogue output X1 are monitored by the charging system to
ensure that the outputs always provide consistent information. Furthermore, it is checked that the
behaviour after a test triggered by control input X10 is correct.
3.3.2
The circuit-breaker is controlled by the charging control electronics
The circuit-breaker is controlled by the charging control electronics software.
The switching output X12 and the analogue output X1 are monitored by the charging system to
ensure that the outputs always provide consistent information. Furthermore, it is checked that the
behaviour after a test triggered by control input X10 is correct.
Note
:
In order to comply with the switching times required by the standard (CCID20),
the
switching time of the circuit-breaker
(incl. driver circuit)
must not
exceed
10 ms!
Mains
Charging
Control Electronics
RCMB101
Us+
Us-
GND
X12
X10
X1
Circuit-
Breaker
Driver circuit
&
Supply
Switching
Output
Analogue
Output
enable
Control
Input
to Load cable
Mains
Charging
Control Electronics
RCMB101
Us+
Us-
GND
X12
X10
X1
Circuit-
Breaker
to Load cable
Driver Circuit
Supply
Switching
Output
Analogue
Output
Control
Input
enable
Содержание RCMB101
Страница 21: ...Technical data 21 TGH1463en 11 2012 4 4 Dimension diagrams Dimensions are given in mm...
Страница 22: ...Technical data 22 TGH1463en 11 2012...
Страница 23: ......