![Bender CC612 EV Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/bender/cc612-ev/cc612-ev_quick-start-manual_2731540005.webp)
CC612(4G)_D00325_05_Q_XXEN / 10.2019 5
CC612 EV charge controller
Legend
A
Connector Current Transformer (CT)
d
Contactor
B
Connector User Interface
e
Type 2 socket*
C
Connector
f
Type 2 plug*
D
Connection Current Transformer (CT)
g
Control pin (contactor)
E
Connection User Interface (RJ45)
h
PLC (optional) via this terminal
F
Connection Modbus/eHZ meter (RJ10)
i
Relay output 1
a
RCD Type A
j
Relay output 2
b
Rectifier
m
Optocoupler input 1
c
Current Transformer (with plug)
n
Optocoupler input 2
Other ways of connecting the charge controller can be found in the operating manual.
Terminal assignment
A1
IN
C1
PP
A2
+
C2
CP
A3
OUT
C3
21
A4
-
C4
24
B1
12V
C5
IN1-
B2
0V
C6
IN1+
B3
11
C7
IN2-
B4
14
C8
IN2+
i
Charge Controller CC612
The SIM card reader and antenna socket are available on data gateways with 4G modem only.
Data gateways with 4G modem are:
CC612-1M4PR
CC612-2M4PR
CC612-2M4R
PLC is optional.
Relay
The relay used to control the contactor is rated for 30 V/1 A. An intermediate relay may be re-
quired if this rating is inadequate.
Contactor
The relay contactor can also be connected to a cable with a type 1 or type 2 plug.