5
WHAT IF...
3.1
I SUSPECT A GAS LEAK
If you suspect a gas leak, turn off the gas supply
at the gas meter, and contact your installer or
local gas supplier. If you require further advice
please contact your nearest Service & Technical
Helpline
(0870-264-1220)
.
3.2
I FREQUENTLY ‘TOP-UP’ OR ‘RE-PRESSU-
RISE’ THE SYSTEM
If the system regularly requires topping-up or re-
pressurising, it may be indicative of a leak. Please
contact your installer and ask him to inspect the
system.
3.3
THE FAULT LIGHT IS ON
If the red LED is illuminated it indicates that the
appliance has ‘locked-out’ or has an internal fault.
To reset the appliance, make sure the gas supply
is on to the appliance. Turn the mode selector
switch to the OFF position for a few seconds and
then turn it back to its previous position. If the red
LED stays on or is illuminated after a few seconds
call an engineer.
COLOUR
FREQUENCY
FAULTS/STATUS
ACTION REQ’D
Green
Flashing every 6-seconds
At stand-by with no faults
None
Flashing 8-times every second
SARA function
None
On every 0.5 second
Temporary fault
Wait
Yellow
On every 0.5 second
Service function
Contact service centre
On permanently
DHW fault
Contact service centre
Red
On every 0.5 second
Safety shutdown and/or
Check pressure gauge
internal fault
Check gas supply
Leave 2-minutes and reset
appliance, if fault continues,
contact service centre
On permanently
Appliance overheat
Contact service centre
APPLIANCE LED STATUS INDICATOR
3.4
THE APPLIANCE IS DUE ITS ANNUAL SERV-
ICE
Please contact the Service & Technical Helpline
(0870-264-1220)
if you would prefer an author-
ised engineer or agent to service your appliance.
Alternatively your local CORGI registered engi-
neer may be able to service the appliance for you.
If you are a tenant your landlord will arrange for
servicing.
3.5
I NEED TO CALL AN ENGINEER
If you think your boiler may have developed a
fault, please contact your installer or the Service
& Technical Helpline
(0870-264-1220)
. Have all
your details to hand including full address and
postcode, relevant contact numbers and your
appliance logbook.
3.6
I WANT TO EXTEND THE WARRANTY
You can if you wish, extend the warranty on your
SABRE HE boiler. Simply contact our Service &
Technical Helpline
(0870-264-1220)
for further
information.
MINIMUM CLEARANCES
Please observe the following minimum clearances required for the safe operation and maintenance of this appliance
Above the appliance
150mm
6 inches
Below the appliance
150mm
6 inches
Left hand side of appliance
50mm
2 inches
Right hand side of appliance
12mm
1/2 inch
In front of appliance
600mm
24 inches
Содержание SABRE 25 HE