background image

5

WHAT IF...

3.1

I SUSPECT A GAS LEAK

If you suspect a gas leak, turn off the gas supply
at the gas meter, and contact your installer or
local gas supplier. If you require further advice
please contact your nearest Service & Technical
Helpline

 (0870-264-1220)

.

3.2

I FREQUENTLY ‘TOP-UP’ OR ‘RE-PRESSU-
RISE’ THE SYSTEM

If the system regularly requires topping-up or re-
pressurising, it may be indicative of a leak. Please
contact your installer and ask him to inspect the
system.

3.3

THE FAULT LIGHT IS ON

If the red LED is illuminated it indicates that the
appliance has ‘locked-out’ or has an internal fault.
To reset the appliance, make sure the gas supply
is on to the appliance. Turn the mode selector
switch to the OFF position for a few seconds and
then turn it back to its previous position. If the red
LED stays on or is illuminated after a few seconds
call an engineer.

COLOUR

FREQUENCY

FAULTS/STATUS

ACTION REQ’D

Green

Flashing every 6-seconds

At stand-by with no faults

None

Flashing 8-times every second

SARA function

None

On every 0.5 second

Temporary fault

Wait

Yellow

On every 0.5 second

Service function

Contact service centre

On permanently

DHW fault

Contact service centre

Red

On every 0.5 second

Safety shutdown and/or

Check pressure gauge

internal fault

Check gas supply
Leave 2-minutes and reset
appliance, if fault continues,
contact service centre

On permanently

Appliance overheat

Contact service centre

APPLIANCE LED STATUS INDICATOR

3.4

THE APPLIANCE IS DUE ITS ANNUAL SERV-
ICE

Please contact the Service & Technical Helpline

(0870-264-1220)

 if you would prefer an author-

ised engineer or agent to service your appliance.
Alternatively your local CORGI registered engi-
neer may be able to service the appliance for you.
If you are a tenant your landlord will arrange for
servicing.

3.5

I NEED TO CALL AN ENGINEER

If you think your boiler may have developed a
fault, please contact your installer or the Service
& Technical Helpline

 (0870-264-1220)

. Have all

your details to hand including full address and
postcode, relevant contact numbers and your
appliance logbook.

3.6

I WANT TO EXTEND THE WARRANTY

You can if you wish, extend the warranty on your
SABRE HE boiler. Simply contact our Service &
Technical Helpline

 (0870-264-1220)

 for further

information.

MINIMUM CLEARANCES

Please observe the following minimum clearances required for the safe operation and maintenance of this appliance

Above the appliance

150mm

6 inches

Below the appliance

150mm

6 inches

Left hand side of appliance

50mm

2 inches

Right hand side of appliance

12mm

1/2 inch

In front of appliance

600mm

24 inches

Содержание SABRE 25 HE

Страница 1: ...Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER G C NUMBER SABRE 25 HE N 470 94 70 SABRE 29 HE N 470 94 71 SABRE 35 HE N 470 94 72 0694 51BQ3030 ...

Страница 2: ...want to extend the warranty 5 Dear Customer Your Sabre HE boiler has been designed to meet and exceed the very latest standards in gas central heating technology and if cared for will give years of reliable use and efficiency Your Sabre HE is a combination boiler supplying central heating and instantaneous domestic hot water Features included are an integral time clock LED indicators showing the s...

Страница 3: ...des to operate 1 3 2 HOT WATER ONLY when the mode selector switch is in the HOT WATER ONLY position the appliance will operate as above However when a hot water outlet is opened the appliance will operate to provide hot water until the demand for hot water has been satisfied NOTE Theappliancedeliversafixedmaximumflowrate of hot water therefore if a hot water outlet is turned on full it is most lik...

Страница 4: ...The system can be shut down for short periods by simply turning the mode selector to the OFF position It is also advisable to turn off the main water supply to the house 2 5 SHUT DOWNTHE SYSTEM FOR LONG PERI ODS If the house is to be left unoccupied for any length of time especially during the winter the system should be thoroughly drained of all water The gas should be turned off at the meter and...

Страница 5: ...cond Safety shutdown and or Check pressure gauge internal fault Check gas supply Leave 2 minutes and reset appliance if fault continues contact service centre On permanently Appliance overheat Contact service centre APPLIANCE LED STATUS INDICATOR 3 4 THE APPLIANCE IS DUE ITS ANNUAL SERV ICE Please contact the Service Technical Helpline 0870 264 1220 if you would prefer an author ised engineer or a...

Страница 6: ...NOTE ...

Страница 7: ......

Страница 8: ...eating Services provides after sales assistance and Technical advice for Sabre Boilers Service Technical Helpline 0870 264 1220 We reserve the right to change the specifications without prior notice Consumers statutory rights are not affected ...

Отзывы: