background image

 
 

-12V

Gear Motor

(+)

(-)

Power Distribution 

PCB Output

GND

Black

PWR Supply

12VB

GND

12VB

Pin 7

J201

Power Distribution 

PCB Output

12V

C9

C4

Power Distribution 

PCB Output

GND

Pin 2

J102

Pin 9

Pin 10

J102

Pin 6

Pin 7

C8

Blue

Claw Rotate Control

Right

Pin 1

J2

1
2

Floor Lift 

Down Limit

Black

White/Black

PCB Air Pump

PCB Air Pump

Left

Yellow/Green/Red

Green/White

Yellow

Air Valve

2

1

2
3

4

1

J3

M

J301

C10

Prize 

Counter

Coin 

Counter

Blue/Grey

Black

White/Yellow

Green/Red

Violet/White

J1

Air Pump

Power Distribution 

PCB Output

Grey/Green

Yellow/Red/Green

Black

Violet/Black

 

 

 

20

 

Содержание Acme Crane Company

Страница 1: ...70 MAN C...

Страница 2: ...1...

Страница 3: ...11 Clean Floor Lift Optos 11 Replace Crane Mechanism 12 Replace Side Glass 12 Replace Prize Sensor 13 Replace Floor Lift Sensors 14 Replace Power Supply 14 Replace Power Input Fuses 14 Troubleshooting...

Страница 4: ...ike traditional solenoid operated claws there is no need for wires at the claw Crane Mechanism Motors and Limit Switches All motors in the Acme Crane are stepper motors The crane always knows where th...

Страница 5: ...Marquee follow the instructions under Changing the Marquee Light Bulbs in the Maintenance section Proceed with set up 1 Remove playfield support blocks1 installed for shipping skip this step for extre...

Страница 6: ...is step for extreme models Unpack control panel1 from the inside of the crane and mount to the front door from the inside using supplied nuts Connect the control panel harness2 to the control panel co...

Страница 7: ...If using a coin comparator styl mechanism install the coin that will be used in the mechanism in the comparator slot on the 7 Power the game on to the AC input and toggle the mechanism Attach power c...

Страница 8: ...r pressure gage ure 2 when the pump3 is running To adjust the claw strength 1 Put the game into adjustment mode by holding the crop claw button on the control panel and the SW2 button4 on th pump for...

Страница 9: ...ulses to Value uto Plushing fluffs the plush during attract mode to keep the merchandise from packing isabled ttract Sounds lay approximately every 5 minutes when the game is not being played when isa...

Страница 10: ...elapsed the game returns to normal play mode Attempts per credit Sets the maximum number of attempts per credit that a player has to win a prize The game ends when a player wins a prize or when t set...

Страница 11: ...mp the joystick up to option 7 Auto Plushing 3 Bump the joystick to the right until the 2 display credit display3 shows 4 Press the Drop Claw button5 display will show or OK 5 Bump the joystick up unt...

Страница 12: ...p Return Claw Opto C Spray Drop Claw Opto1 located behind the claw lift pulley2 with lean the Floor Lift Optos ransmitter pressurized air Clean about once every six months C Spray floor lift opto t 1...

Страница 13: ...e Panel Securing Nuts4 8 Remove Upper Side Panel5 by lifting straight up off of the top of the cabinet 9 With proper ceiling height slide side glass up and out of Corner Extrusions6 10 Fit rubber edgi...

Страница 14: ...e prize floor and hole covers Replace Prize Sensor X treme Model 1 Disconnect AC power from the machine 2 Open the front door 3 Disconnect Prize Sensor Harness1 from the main harness 4 Remove Security...

Страница 15: ...er cover to the side to access fuses2 3 Replace fuses 5 Amp and push fuse holder back into position Troubleshooting Guide Coin Mechanism will not take coins No coin installed or coin improperly instal...

Страница 16: ...to drive the mechanism The problem is almost certainly a mechanical bind or an electrical connection to the motor s o Check to see if there is a mechanical bind by moving the claw by hand with the gam...

Страница 17: ...sor check the power and connections to the sensor boards If OK you may have a bad sensor Elevator does not lift Check to see that the dip switch setting for Auto Playfield Floor Adjustment is enabled...

Страница 18: ...10 Brown 3 Pin 4 J201 Violet Orange Green 2 1 USER LAMP 25 WATT BLACK WHITE CABLE C16 C7 C15 Yellow Black Black Black Black Yellow Yellow 9 Black 7 1 FOR 230 VOLT CHANGE THE 6 LAMPS TO 230 VOLT MODEL...

Страница 19: ...lue Y Axis Motor Yellow White Violet Yellow Black Pink Orange Black White Black Red GND 12V 5V GND Claw Rotate Control Pin 7 Pin 6 Pin 5 GND Z Axis Opto Sensor Pink Green Pin 2 Pin 2 Pin 4 Pin 3 Pin 6...

Страница 20: ...in 6 GND Black Green Red White Red White Yellow Red Orange 5V GND 12VB Coin Mech 1 Coin Mech 2 Back Drop Claw Button Left Forward Dollar Bill Validator Brown Yellow Pin 4 Power Distribution PCB Output...

Страница 21: ...in 10 J102 Pin 6 Pin 7 C8 Blue Claw Rotate Control Right Pin 1 J2 1 2 Floor Lift Down Limit Black White Black PCB Air Pump PCB Air Pump Left Yellow Green Red Green White Yellow Air Valve 2 1 2 3 4 1 J...

Страница 22: ...12V Black Pink Yellow White Yellow Pin 2 C14 Black Yellow Grey Yellow Black Pin 1 Pin 3 Pin 2 J201 Pin 9 Yellow Pin 1 Pin 2 Pin 3 White Blue Yellow Black Pin 3 Black Pink Blue Pin 8 White Blue Red 12V...