19
User Instructions
Continued
Advance mode
Under the daily and week timer mode Pressing will turn the heater
on or off
Window open detection
When the transmitter detects a rapid drop in room temperature, it will be
judged as a window open, the warning icon will be displayed and the
heater will be turned off automatically. After the indoor temperature has
risen or by manual intervention (by operating remote control), the
heater will return to its normal working state.
Pairing the handset to the appliance
The below operation should be carried out before programming, when
changing to a new remote or in the event the appliance cannot be
controlled by the remote:
Hold the reset button on the appliance for 3 seconds (a pen point may
needed) until you hear 3 short beeps from the unit, release the button.
Press the button on the remote, the programming is finished when
you hear 1 long beep from the appliance.
Resetting the remote control is necessary if the appliance operates
incorrectly or does not respond when operated. Open the back cover
of the remote control.
Press the Reset button. Follow the above steps
Remote control operation
Resetting the Thermal Cut Out
The appliance is fitted with an Electronic Safety Control (E.S.). This is a safety device,
which switches off the fire if, for any reason, the appliance overheats, e.g. if covered. If
the heater stops operating while the flame effect continues working normally, this
indicates that the E.S. Control is in operation. The E.S. Control can only be reset after the
appliance has cooled down, and the appliance has been reset. Resetting of the E.S.
Control proceeds is as follows:
Switch off the appliance (Manual On / Off switch) and leave it off for approximately
10-15 minutes.
Remove any obstruction to the fan heater outlet or fan blades etc. Make sure that the
power supply is disconnected with the plug socket outlet while doing this.
Switch on the appliance and the E.S. Control will be re-set.
Ensure that the appliance is functioning correctly. If the E.S. Control operates again, the
appliance should be checked by a competent electrician.