![bemodern BM06 Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/bemodern/bm06/bm06_user-and-installation-instructions-manual_2731135015.webp)
Setting up the communication between the remote and appliance
R31 The below operations should be carried out before programming, when changing
to a new remote or in the event the appliance cannot be controlled by the remote:
• Hold the reset button on the appliance for 3 seconds (pen point may needed) until
you hear 3 short beeps from the unit, release the button.
• Press the
button on the remote, the programming is finished when you hear 1
long beep from the appliance
R32 Resetting the code for remote control is necessary if the
appliance operates wrongly or the remote control does not operate
correctly.
• Open the back cover of the remote control.
• Press the Reset button on the remote control.
• Follow the steps R31
Adaptive Start Control
R28 According to room temperature and set temperature, the heater will
automatically come on in time to heat the room to the set temperature at the set
time. For example, if your timer is set to start at 18:00 and temperature is set to
23°C, the fire will come on at 17:30 to ensure the room is 23°C at 18:00.
Window Open Detection
R29 When the transmitter detects a rapid drop in
room temperature, it will be judged as a window
open, the warning icon will be displayed and the
heating will be turned off automatically.
R30 After the indoor temperature has risen or a
manual override of the warning (by operating remote
control) has been done, the fire will return to normal
working state.