150W (energy-saving lamp) Detection Motion Speed: 0.6-1.5m/s
FUNCTION:
Can identify day and night: It can work in the daytime and at night when it is adjusted to the
“000” position (LUX). It can work in the ambient light less than 5LUX when it is adjusted to
the “001” position (LUX). As for the adjustment pattern, please refer to the testing pattern.
SENS adjustable: It can be adjusted according to using location; low sensitivity with 2m for
detection distance; High sensitivity with 8m, it fits for large room.
Time-Delay is added continually: When it receives the second induction signal after the first
induction, it will compute time once more on the basic of the first time-delay rest.
Time–Delay is adjustable. It can be set according to the consumer’s desire. The minimum
time is 5sec.The maximum is 10min.
NOTE: the high-frequency output of the HF sensor
is <0.2Mw- that is just one 100
th
of the transmission
power of a mobile phone or the output of a
microwave oven, the baby can't touch it
INSTALLATION: (see the diagram)
Switch off the power.
Fix the bottom on the selected position with the inflated screw
through the screw holes in the side of the sensor.
Connecting the power and the load to sensor as per the
connection-wire sketch diagram.
Switch on the power and test it
CONNECTION-WIER SKETCH DIAGRAM
Connecting the power source into the ”N” , ”L” according to
connection wire diagram when you install it.
TEST:
Slide the SENS knob: The first knob on “1” position,
the second knob on “0” position. Slide the TIME knob:
The first knob and second knob on “0” position, the
third knob on “1” position. Slide the LUX knob: first
knob on “0” position, second and third knob on “0”
position.
When you switch on the power, the light will be on at
once, and later will be off automatically. Then if the
light receives induction signal, it can work normally
After 5sec of the first detection, the light could work again. If there is no induction signal, the
load should be stopped working within 5sec.
Slide LUX knob, if it is adjusted to 5 LUX, the inductor load should not work after load stops
working. Under no induction signal condition, the load should stop working within 5sec.
Note: when testing in daylight, please slide LUX knob to 2000lux, otherwise the sensor
light could not work!
NOTES
:
:
:
:
Electrician or experienced human can install it.
Can not be installed on the uneven and shaky surface
In front of the sensor there shouldn’t be obstructive object affecting detection.
Avoid installing it near the metal and glass which may affect the sensor.
For your safety, please don’t open the case if you find hitch after installation.
In order to avoid the unexpected damage of product, please add a safe device of current 6A
when installing microwave sensor, for example, fuse, safe tube etc.
SOME PROBLEM AND SOLVED WAY
The load don’t work:
a. Check the power and the load.
b. Whether the indicator light is turned on after sensing? If yes, please check load.
c. If the indicator light is not on after sensing, please check if the working light
corresponds to the ambient light.
d. Please check if the working voltage corresponds to the power source.
The sensitivity is poor:
a. Please check if in front of the sensor there shouldn’t be obstructive object that