background image

Step by Step Product Knowledge  

BEMER Pro Program Mode

Push Programs and you will see…………… 3 pre-programmed settings 

P1, 

P2, and P3

Содержание B.Box Pro

Страница 1: ...How To Use Your BEMER Pro Device ...

Страница 2: ...ses Car Adapter Plug Foot Protector Wall Mount 4 power cords 2 manuals Quick Start Guide B Box Pro B Body Pro B Pad B Grip B Spot B Light B Scan B Grip fixing strap Please note Use surge protector unplug when not in use Step by Step Product Knowledge BEMER Pro ...

Страница 3: ...lighter grey top and hold the darker grey bottom with the rest of your fingers Firmly push back back with your thumbs It will slide back and tilt upward Let it tilt up on its own To put back into flat position just press down at the top back and gently slide toward the front ...

Страница 4: ...o Touch screen Edit mode Programmable 2 in 1 functionality Set the local time Turning on the B Box Takes approx 45 seconds to activate the computer inside Step by Step Product Knowledge Operating the BEMER Pro ...

Страница 5: ...You will see 4 Modes Intensity Program Special Sleep Light Step by Step Product Knowledge Operating the BEMER Pro A1 Port A2 Port ...

Страница 6: ...IMPORTANT NOTE ALWAYS connect the magnetic plugs gently Step by Step Product Knowledge Operating the BEMER Pro top down outside in bottom up ...

Страница 7: ...he connection to the port is lost and the applicator will not work Make your customers aware Due to the strong pull of the magnets on both applicator plug and the port it is easy to let the plug slam NOTE The B Box will alert you with a beeping noise and an error message Step by Step Product Knowledge Operating the BEMER Pro ...

Страница 8: ...g Push start Using 2 ports at the same time Connect plug for another applicator to A2 Select the desired mode and setting Push Start NOTE You can always go back and forth between the 2 ports by pressing on the arrow between A1 and A2 Step by Step Product Knowledge Operating the BEMER Pro ...

Страница 9: ...nsity Level 5 no Plus Week 6 Intensity Level 6 with Plus Intensity Level 6 no Plus Week 7 Intensity Level 3 with Plus Intensity Level 3 no Plus 1 x during this week Week 8 Intensity Level 4 with Plus Intensity Level 4 no Plus 2 x during this week Week 9 Intensity Level 5 with Plus Intensity Level 5 no Plus 3 x during this week Week 10 Intensity Level 6 with Plus Intensity Level 6 no Plus 4 x durin...

Страница 10: ...e biggest disturbance in microcirculation is A lot of people are very toxic and should start with low intensities Using the Basic Plan is helpful to go layer by layer deeper and deeper into the tissues to activate vasomotion Step by Step Product Knowledge Basic Plan ...

Страница 11: ...he energy output of the electromagnetic field in this example Intensity Level 3 will jump to Intensity Level 10 This is based on Dr Klopp s observation that vasomotion occurs about every 20 seconds This additional stimulus leads to more efficacy It may be too much stimulation for some people especially in the evening Step by Step Product Knowledge The Plus Signal ...

Страница 12: ...Step by Step Product Knowledge The Plus Signal ...

Страница 13: ...Step by Step Product Knowledge BEMER Pro Program Mode Push Programs and you will see 3 pre programmed settings P1 P2 and P3 ...

Страница 14: ...inutes Intensity 2 for 2 minutes Intensity 3 for 2 minutes Intensity 4 for 4 minutes Step by Step Product Knowledge BEMER Pro Program Mode Note each bar of the graph denotes a 2 minutes period of the entire session ...

Страница 15: ...edge BEMER Pro Program Mode Program 2 16 minutes Intensity 2 for 4 minutes Intensity 3 for 4 minutes Intensity 4 for 4 minutes Intensity 6 for 4 minutes Note each bar of the graph denotes a 2 minutes period of the entire session ...

Страница 16: ...inutes Intensity 7 for 4 minutes Intensity 8 for 4 minutes Intensity 9 for 4 minutes Intensity 10 for 4 minutes Note each bar of the graph denotes a 2 minutes period of the entire session Step by Step Product Knowledge BEMER Pro Program Mode ...

Страница 17: ...magnetic field strength and reaches different layers Combining different intensities within one application reaches different tissue layers in one application We never know where in the tissue the biggest disturbance is in Microcirculation Step by Step Product Knowledge BEMER Pro Program Mode ...

Страница 18: ...o activate the Night Program just push on Special NOTE The BEMER Night Program configuration Intensity Level 2 7 Microtesla NO plus 10 Hz Frequency Step by Step Product Knowledge BEMER Pro Night Program ...

Страница 19: ... forth between hour and minutes you will use the left and right arrows NOTE The Night Program only works when the amount of sleep is from 6 hours up to 10 hours of sleep This is reflected by the time line This number needs to be white The OK button is highlighted Step by Step Product Knowledge BEMER Pro Night Program ...

Страница 20: ...5 hours and 59 minutes This amount of time does not allow you to activate the Night Program NOTE Because the time line number is less than 6 hours of sleep the OK button is NOT highlighted If it was more than 10 hours it would be the same Step by Step Product Knowledge BEMER Pro Night Program ...

Страница 21: ...You set your wake up time for 6 AM The numbers in the hour box should be 6 and the numbers in the minute box should be 00 The time line number will say 7 00 h The OK button is highlighted Press OK Step by Step Product Knowledge BEMER Pro Night Program ...

Страница 22: ...see the left bar highlighted and the B Body graphic starts blinking NOTE The sleep program runs the first 2 hours after activation then it shuts down and turns on 2 hours prior to the wake up time Step by Step Product Knowledge BEMER Pro Night Program ...

Страница 23: ...gram Supports redistribution of blood to the organs involved in Detoxification Regeneration Repair Organs involved are Liver Kidneys Gastro intestinal tract Skin Step by Step Product Knowledge BEMER Pro Night Program ...

Страница 24: ...Press Light NOTE You can use the light for any skin related issues The red LED light only penetrates into the layers of the skin Step by Step Product Knowledge BEMER Pro Light Mode ...

Страница 25: ...Select the desired amount of minutes NOTE Depending on the sensitivity of skin you may want to start with 2 minutes Step by Step Product Knowledge BEMER Pro Light Mode ...

Страница 26: ...y of skin using a lower setting may sometimes be advisable NOTE If using the light in the face it is advisable to utilize the glasses For severe skin issues from chronic wounds to severe disturbances it is advisable to seek advice from our medical hotline Step by Step Product Knowledge BEMER Pro Light Mode ...

Страница 27: ...TE You can set your B Box to your local time which shows in the upper right hand corner Push SET icon on the bottom right hand side of the initial screen Step by Step Product Knowledge BEMER Pro Settings ...

Страница 28: ...you haven t set the clock the sleep program will not work properly Military time is used counting from 00 00 to 24 00 Push the TIME icon Step by Step Product Knowledge BEMER Pro Settings Setting the local time ...

Страница 29: ...ngs Use UP or Down arrows to adjust for hour and minutes Use Left or Right arrow to switch back and forth between minutes and hour NOTE you can only adjust either hour or minutes only when either box is highlighted Press SAVE Setting the local time ...

Страница 30: ...Step by Step Product Knowledge BEMER Pro Settings Adjusting the Brightness Push Brightness Use the left arrow to dim the display screen Save the desired setting ...

Страница 31: ...Step by Step Product Knowledge BEMER Pro Settings Adjusting the Volume Push Volume Use left arrow to adjust the volume Save the desired setting NOTE 3 bars loudest no bars no volume ...

Страница 32: ...o Settings The Program Editor You will see an empty bar Use UP arrow to fill bar to desired setting Use right arrow to create another bar NOTE Longest setting is 20 minutes get familiar with your BEMER first before creating your own Programs ...

Страница 33: ...ted High EMF is 3 times stronger than normal output Down arrow highlighted Low EMF is normal output NOTE Local applicators should be used on High however to substitute the basic plan with the B Pad or B Sit you can set it to low By default Output for B Body is low and B Spot is high ...

Страница 34: ...Step by Step Product Knowledge BEMER Pro Settings INFO Push INFO icon This area gives you information about the software in use and how many hours each port has been in use Press OK ...

Страница 35: ...ngs Power Save Push left or right arrow to see the Power Save icon If the Power Save is on you will see the lightning bolt above The unit automatically shuts off if not in use If Power Save is turned off lightning bolt disappears and unit stays on ...

Страница 36: ...Step by Step Product Knowledge B Scan WORD OF CAUTION The B Scan is NOT a diagnostic tool It merely detects whether an electromagnetic field emanates from any of the applicators ...

Страница 37: ... of your body if that is more comfortable e g for people who are immobile or bed ridden It does not have to be totally flat and can be covered by a sheet or towel for cleanliness NOTE Put your head where the power cord comes out of the B Body Step by Step Product Knowledge BEMER Pro ...

Страница 38: ...deeper laying or denser tissue use higher intensities Caution This tissue may have lots of inflammation and requires a slow approach similar to basic plan BEMER Pro Local applicators B PAD B SPOT B LIGHT Step by Step Product Knowledge BEMER Pro ...

Страница 39: ...cuts bee stings sprains etc Accidents For chronic issues where we can identify the specific area Accelerates and promotes localized repair and innate healing capacity NOTE BEMER is never a substitute for medical advice Step by Step Product Knowledge BEMER Pro ...

Страница 40: ...t harm you BEMER is not symptom or disease specific There are no specific settings to use for specific symptoms One setting may work for one person while it is not working for another NOTE BEMER is never a substitute for medical advice Step by Step Product Knowledge BEMER Pro ...

Страница 41: ...th an organ transplant when the user is till on immuno suppressants Seek medical advice first before using BEMER with unexplained fevers pregnancy INRs should be checked weekly when on Coumadin Warfarin or like medications Step by Step Product Knowledge BEMER Pro Caution ...

Страница 42: ... to avoid do not keep liquids near B Box Surge protector good idea to use surge protectors AC to DC conversion happens in the converter box Schedule Insurance for home owners for 10 Never put your B Box into checked luggage Always put it into your carry on Step by Step Product Knowledge BEMER Pro ...

Отзывы: