RPI M50A_12s

Quick Installation Guide

Europe

Содержание RPI M50A_12s

Страница 1: ...RPI M50A_12s Quick Installation Guide Europe...

Страница 2: ...C connection type 18 Inverter ID 19 Baud rate for RS485 19 Active power limitation 20 External shutdown 20 Dry contacts 21 12 Technical data 22 Copyright Delta Energy Systems Germany GmbH All rights r...

Страница 3: ...cover only when it is absolutely necessary Do not remove the cover if water might enter the inverter After work is completed ensure that the cover is properly replaced and screwed in Check that the c...

Страница 4: ...4 5 6 Electrical connections Overview 1 2 3 4 5 6 1 Grounding connection 3 AC connection 5 Communication port 1 2 AC DC isolating switch 4 DC connections 6 Communications port 2 not used 1 Display bu...

Страница 5: ...o life through electric shock Potentially fatal voltage is applied to the inverter during operation This voltage persists even 10 seconds after disconnection of the power supply Never open the inverte...

Страница 6: ...erter housing with spring washer washer and lock washer mounted on the inverter DC plug 12 Multi contact MC4 plug for DC 32 0017P0001 UR for 4 6 mm2 Quick installa tion guide and basic safety instruct...

Страница 7: ...r flow Ambient temperature and air circulation The inverter is very heavy The wall has to be able to bear the weight of the inverter Always use the mounting plate supplied with the inverter Use mounti...

Страница 8: ...nting the inverter on the wall 1 Attach the mounting plate to the wall the mounting system with 6 or 12 M6 screws 2 Mount the inverter on the mounting plate 3 Check that the inverter is correctly moun...

Страница 9: ...sufficient conductive connection scratch away the paint from the inverter housing under the lock washer to achieve a better electrical contact Attaching warning notices to the inverter Attach all nece...

Страница 10: ...se grids with neutral conductor L1 L2 L3 N PE Use cable end sleeves on every wire L1 L2 PE N L3 L3 N L2 L1 PE L1 L2 PE L3 N Wiring for 3 phase grids without neutral conductor L1 L2 L3 N PE Use cable e...

Страница 11: ...quality of the solar modules the size of the PV system and the ambient conditions e g humidity The tripping current must not how ever be less than the specified minimum tripping current Integrated str...

Страница 12: ...maximum current of the DC connections when planning the installation NOTE Incorrectly dimensioned solar plant An solar system of the wrong size may cause damage to the inverter When calculating the mo...

Страница 13: ...solar modules DC plugs and DC cables The DC plugs for all DC connections are provided along with the inverter If you want to order more or need a different size see the infor mation in the following...

Страница 14: ...485 Terminal pairs 3 4 or 5 6 can be used It doesn t matter which terminal pair is used The second terminal pair is only required when connecting several inverters via RS485 If you want to use SOLIVIA...

Страница 15: ...termination resistor on the first inverter After the startup of each inverter configure another inverter ID see Inverter ID page 19 Inverter ID page ON 1 2 ON 1 2 ON 1 2 RS485 Termination resistor OFF...

Страница 16: ...ve power to 100 7 K5 V1 K5 Reserved 8 K6 V1 K6 Reserved To control the active power an external ripple control receiver can be connected to the digital inputs After startup the relays can be defined a...

Страница 17: ...NT button to confirm TH PEA UK G59 3 230 2 Use the buttons and to select your country or grid type Press the ENT button to confirm YES NO UK G59 3 230 set country Are you sure to 3 If the correct coun...

Страница 18: ...s setting if you are using an AC system with 3 phases PE 3P3W For a description of how to connect the inverter to the grid see Con necting to the grid AC page 10 Connecting to the grid AC E Today 0kWh...

Страница 19: ...re the value and press the ENT button Inverter ID E Today 0kWh Power 0W Status On Grid 10 Sep 2014 15 32 1 If the default information is displayed press the ESC button to open the main menu Otherwise...

Страница 20: ...e ENT button to confirm a number AC Connection 3P4W EPO Normal Close Anti islanding ON Max Power 50000W Return to Factory 4 Use the buttons and to select the entry Max Power and press the ENT but ton...

Страница 21: ...s Install Settings Active Reactive Pwr FRT 2 Use the buttons and to select the Installation Settings button and press the ENT button Password 0 energy production Adj would affect Warning 3 This functi...

Страница 22: ...A 50 A 50 A Maximum short circuit power upon fault 72 A 12 A per string Number of MPP trackers Parallel inputs 1 MPP tracker separate inputs 2 MPP tracker Number of DC inputs total DC1 DC2 12 6 6 Elec...

Страница 23: ...e sea level Standards and guidelines RPI M50A_12s Protection type IP65 Protection rating I Pollution level II Overload behavior Current limiting power limiting Safety IEC 62109 1 2 CE compliance EMV E...

Страница 24: ...inverter com 0800 800 9323 toll free Great Britain support uk solar inverter com 0800 051 4281 toll free Greece support greece solar inverter com 49 7641 455 549 Israel supporto israel solar inverter...