background image

 

 
 
 
 
 
 
 
 
 

BARO-G 

Roll-In Rack Oven 

 

 

Operator’s Manual 

 

 

 

 

 

Belshaw /Adamatic Bakery Group 

814  44

th

 Street NW, Suite 103 

Auburn, WA 98001  USA 

Phone: 206-322-5474 

Fax: 206-322-5425 

http://www.belshaw.com 

022208 

Содержание BARO-G

Страница 1: ...BARO G Roll In Rack Oven Operator s Manual Belshaw Adamatic Bakery Group 814 44th Street NW Suite 103 Auburn WA 98001 USA Phone 206 322 5474 Fax 206 322 5425 http www belshaw com 022208...

Страница 2: ......

Страница 3: ...HE EVENT THAT USER SMELLS GAS THIS INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER AS A MINIMUM TURN OFF THE GAS AND CALL YOUR GAS COMPANY AND YOUR AUTHORIZED SERVICE AGENT EVACUAT...

Страница 4: ......

Страница 5: ...TION 7 4 INSTALLATION INSTRUCTIONS 10 5 EMERGENCY OPERATION 17 6 GENERAL OPERATION 18 7 GENERAL MAINTENANCE 19 8 RESISTANCE CHARTS 21 9 SAFETY CONSIDERATIONS 22 10 ILLUSTRATED PARTS BREAKDOWN 23 11 CO...

Страница 6: ...SWITCH IS TURNED OFF SWITCH THE MAIN BREAKER AT THE WALL TO OFF WHEN SERVICING THE OVEN PG 8 CAUTION TO REDUCE THE RISK OF FIRE THE APPLIANCE IS TO BE MOUNTED ON FLOORS OF NON COMBUSTIBLE CONSTRUCTIO...

Страница 7: ...CSA C22 2 PG 11 WARNING INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND OR DAMAGE TO EQUIPMEN...

Страница 8: ...he factory PG 18 NOTICE To maintain optimum safety and performance for oven models BARO 1G BARO 2G it is recommended that a program of scheduled periodic maintenance be implemented It s sole responsib...

Страница 9: ...steel The BARO 1G oven cavity dimensions are 36 5 927 mm wide x 75 1905 mm high x 39 9906 mm deep The interior is constructed of stainless steel The Rack Carrier facilitates smooth and simple rack loa...

Страница 10: ...d The hood can be wired to the external device terminals in the service box This insures the hood is on whenever the oven is on The POWER switch on the oven control panel activates the blower The blow...

Страница 11: ...ETL File 3028821 9 REV B2006 EQUIPMENT DESCRIPTION CONT D Circulation Blower Vent Blower Controls...

Страница 12: ...ent and blower motor assemblies The maximum height needed for tilting the oven up is 105 inches Clear access is needed to the roof or exterior of the facility for hood exhaust Check local codes for co...

Страница 13: ...rklift is not available use a pallet jack and successive stacks of pallets to raise the oven DO NOT LIFT THE OVEN BY HAND Tilt the oven to the vertical position by hand from the raised position Ease t...

Страница 14: ...e the lifter is centered on the rotator shaft Anchor the lifter assembly in place with the fasteners provided Remove the snap ring square washer and shipping spacer from the rotator shaft Remove the r...

Страница 15: ...and move it into place with a hand truck Raise the door hinges over the jamb hinges with the hand truck and lower into place Use care to avoid damaging the door seal Adjust the left front leveling scr...

Страница 16: ...Install 4 5mm truss head stainless steel machine screws through the side support trim and into the top of the hood Attach the rear trim to the opposite end of the hood side support trim using 4 6 mm t...

Страница 17: ...efore proceeding Confirm that all electrical connections are proper and all covers are in place Confirm that the oven is properly grounded Turn on electrical power to the oven Turn on all circuit brea...

Страница 18: ...ETL File 3028821 16 REV B2006 INSTALLATION CONT D CAUTION IF BLOWER ROTATION IS INCORRECT IT WILL CAUSE SEVERE DAMAGE TO HEAT EXCHANGER...

Страница 19: ...rs off 2 Wait until the fire has gone out and oven chamber cools before opening the door WARNING DO NOT REMOVE A FLAMING PRODUCT FROM THE OVEN SEVERE BURNS AND PROPERTY DAMAGE CAN RESULT WARNING THIS...

Страница 20: ...and performance for oven model BARO 1G it is recommended that a program of scheduled periodic maintenance be implemented It s sole responsibility of the user to establish schedule and enforce such a...

Страница 21: ...ETL3028821 19 REV B2006 NOTICE For periodic maintenance and repairs electrical diagrams are included in this manual and with the oven...

Страница 22: ...ETL3028821 20 REV B2006...

Страница 23: ...mocouple in Pressure Panel just behind louvers about waist high not in center of oven Make sure tip of thermocouple does not come in contact with metal when reading air temperature 70403 03 Water Valv...

Страница 24: ...er operator to insure this happens C A regular periodic program of cleaning inspection and maintenance must be established and comprehensive maintenance records maintained It is the sole responsibilit...

Страница 25: ...PLE NPT 4 1 70101 102 BRASS TEE NPT 5 1 70302 39 BRASS PIPE NIPPLE NPT 6 1 70403 03 SOLENOID VALVE WATER 7 1 70307 08 PIPE REDUCER X 3 8 8 1 41100 33 TEMPERATURE SENSING PROBE 9 1 70101 100 COMPRESSIO...

Страница 26: ...Y PART DESCRIPTION 1 1 50800 103 MAIN HANDLE ASSEMBLY 2 1 72609 18 SWEEPER BARO 1 2 1 72609 181 SWEEPER BARO 2 3 1 150 786 FEMALE HINGE ASSEMBLY LOWER 4 1 150 786 1 FEMALE HINGE ASSEMBLY UPPER 5 1 150...

Страница 27: ...ription QTY 2 30701 05 24V Coil Relay 2 Pole 3 3 30402 38 T stat Adj 450 72 C T SP173 1 4 30303 06 Switch Tog On On 2 Pole 1 5 30303 16 Switch Tog On On Mom W Spring 1 6 20102 06 6 32x 3 8 Bolt 2 8 70...

Страница 28: ...31400 31 OBSOLETE TRANSFORMER 10 1 30707 06 OVERLOAD LIFT ROTATE ASSEMBLY USES WITH BASE 30707 07 SEE ABOVE NOTE 10 A 1 30707 07 BASE PLATE FOR 30707 06 11 1 31200 08 GROUND LUG 12 2 31800 13 SINGLE P...

Страница 29: ...ETL File 3028821 27 REV B2006 PARTS LIST CONT D NOTE 30200 57 is obsolete replace with Actuator part 30200 64 All Pass through s use will still utilize a 30200 57 11 25 25 1 40704 08 Capacitor Lift...

Страница 30: ...3 1 70200 12 WASHER 4 1 73000 06a DRIVE GEAR 5 1 73000 05a MOTOR GEAR 6 1 40704 06 MOTOR CAPACITOR 7 1 71500 12 ROTATION MOTOR FAN 8 1 30200 56 DRIVE MOTOR 9 1 30301 15 ROTATOR MICRO SWITCH 10 1 50803...

Страница 31: ...QTY PART DESCRIPTION 1 1 30200 59 MAIN BLOWER MOTOR 1 1 30200 61 SINGLE PHASE ONLY MOTOR 2 1 71500 14 MAIN BLOWER HEAT SINK 3 1 20601 07 RETAINING SNAP RING 4 1 150 368 BUSHING 5 1 71500 13 MAIN BLOW...

Страница 32: ...0 135 LIGHT HOUSING BACK 2 2 31602 07 LIGHT SOCKET 3 1 31600 13 4 FOOT FLUORESCENT BULB 4 2 20201 09 5 16 WASHER 5 1 50803 009 DAMPER ROD 6 1 150 790 DAMPER FORK 7 1 150 353 DAMPER ARM 8 1 150 349 DAM...

Страница 33: ...CB4 15 Amp TB3 Terminal Block 120V Neutral Supply OL2 Lift and Rotation Motor Overload Protection TR1 Transformer 120V 10V Control Circuit TR2 Transformer 120V 24V All Controls MR1 Main 120V supply M...

Страница 34: ...connection pins 1 brown wire from valve goes to pin 1 1 brown wire from valve goes to pin 2 On newer style valve with on off toggle switch a jumper goes from pin 2 to pin 3 If replacing with old style...

Страница 35: ...ETL File 3028821 33 V B2006 Electrical Connections See page 16...

Страница 36: ...heat circuit wires 54 and 45 Check to assure circulation blower contactor is closed and 24VAC is present between wires 49 and 45 ground on ovens built after Jan 2005 If voltage is present 24VAC should...

Страница 37: ...e on BARO 2G 2 5 2 8 NG see tag on valve and 6 LP If gas supply is sufficient and micro amp reading is low replace flame sensor If burner does not stay lit long enough to develop a micro amp reading o...

Страница 38: ...on check bulb and ballast If rack carrier does not lift and rotate check door switch and MR3 for normal operation at this point you should have Preheat in display and 24VAC to MR4 coil If 120VAC is n...

Страница 39: ...MR4 and lower limit switch for normal operation If 120VAC is present between wires 18 and 2 on lift actuator and actuator will not lower check capacitor before changing actuator Burner Screeching or B...

Страница 40: ...uct different size or density Calibration accurate Temps taken inside pressure panel not center of oven See operation instructions or contact factory to enter calibration mode After temperature begins...

Страница 41: ...on outside 2 pins and for 5 Check J1 for 12VAC at this point LD8 should illuminate Check grey communication cable between relay board and CPU display board at this point LD1 and LD2 on CPU should ill...

Страница 42: ...ETL File 3028821 40 V B2006...

Страница 43: ...ETL File 3028821 41 V B2006...

Страница 44: ...ETL File 3028821 42 V B2006...

Отзывы: