Signal pattern
The smoke alarm status LED blinks in red every 40 s to show that it is working correctly.
Depending on the cause of the alarm, the signal patterns are as follows:
Silence function
In case of a nuisance alarm, press the test button to silence it temporarily. The status LED
blinks every 8 s to confirm. For security reasons, the silence function stops after 10 minutes.
Note:
Only use this feature if you are certain about the cause of the alarm, like for instance
harmless cooking fumes. If you have interconnected smoke alarms, you need to silence the unit
that blinks to stop the other units from sounding. If more than one unit is blinking, you need to
silence each smoke alarm separately.
Test interval
It is recommended that you test your smoke alarms and Visit receivers at least weekly to
ensure the units are working, see 'Test and maintenance'.
Power monitoring
When the battery starts to run out, the smoke alarm chirps and blinks every 40 s for a
minimum of thirty days. This smoke alarm features a sealed non-replaceable battery, so
when the battery is depleted you need to replace the unit, see 'End of life'.
Smoke alarm
Visit receiver
Cause
Status LED
Sound
LED Sound
Vibration Flash
Fire/Test
Blinks every s
3 beeps every 4 s
Red
Fire alarm Long
Yes
Low battery Blinks every 40 s Chirps every 40 s
—
—
—
—
Faulty unit
—
Chirps every 40 s
—
—
—
—
Getting started
Installation
1
Remove the mounting bracket from the smoke alarm by turning it counter-clockwise.
2
Taking care to avoid any electrical wiring, fix the mounting bracket to the ceiling or wall
using the supplied screws and plugs. For placement, see 'Location and positioning'.
3
Fit the smoke alarm to the bracket by turning it clockwise until is snaps into place. The
status LED blinks in red every 40 s to show that the unit is on.
1
2
3
Testing
1
Press the test button on the smoke alarm
and release it when the unit starts to beep.
2
The red Visit LED blinks on the receiver and
it starts to sound, flash or vibrate depending
on your receiver. It will time out in about 40 s.
If you have interconnected smoke alarms
(see page 6), they will beep for 10 s and
blink for 5 min. To mute them, press the
test button on each unit.