EN
Quick start guide
Make sure to select a location complying with the advice in
Location and positioning
.
1
Lift off the mounting bracket and carefully place your thumb over the batteries and
remove the pull tab to power the smoke alarm.
2
Taking care to avoid any electrical wiring, fix the mounting bracket to the ceiling or
wall using the supplied screws and plugs. Mount it at least 305 mm (12") from walls
and obstructions, ideally centrally in the room or area.
3
Fit the alarm to the bracket by turning it clockwise until it snaps into place.
Testing the connection
1
Press the test/silence button and release
it when the alarm sounds. The alarm
transmits a radio signal to the receiver.
2
The red Visit LED on the receiver lights up
to show that the signal was received. In
addition, it starts to sound, flash or vibrate
depending on the receiver.
Note:
The alarm will stop sounding after the
button is released and the Visit receiver will
time out in less than a minute.
PULL THIS T
AB
1
1
2
3
2
5
6
Indication summary
Normal operation
Action
LED
Sounder
Power up
Pull battery tab
1 red + 1 yellow blink Off
Standby
Off
Off
Sensing fire
Red + green
Full sound
Silence alarm
Press test button
1 red blink / 8 s
Off for 10 mins
Fault mode
Action
Alarm LED
Sounder
Low battery
1 yellow blink / 48 s
1 beep / 48 s
Faulty smoke sensor
2 yellow blinks / 48 s
2 beeps / 48 s
Faulty heat sensor
2 yellow blinks / 48 s
2 beeps / 48 s
End of life
3 yellow blinks / 48 s
3 beeps / 48 s
Silence end of life
for up to 30 days
Press test button
Off for 72 h
Off for 72 h
Contaminated
chamber
4 yellow blinks / 48 s
Off
Test mode
Action
Alarm LED
Sounder
Test smoke alarm
Press test button
Red + green
Full sound
Alarm memory
Action
Alarm LED
Sounder
24 h memory*
2 red blinks / 48 s
for 24 hours
Off
Memory reset*
Press & hold button
Rapid red blinking
Rapid chirping
Note:
During test and in case of fire, the red LED on the Visit receiver lights up and it
starts to sound, flash or vibrate depending on the receiver.
* See
Alarm memory