9
This appliance is adjusted for NATURAL GAS at 20mbar ONLY.
The hob is suitable for conversion to Liquid Petroleum Gas BUTANE (G30) at 28-30 mbar and PROPANE
(G31) at 37 mbar by the following procedure using the kit supplied.
Replace the injectors with the corresponding injector from the table on page below.
First remove the burner caps and rings and with a socket spanner “B”, unscrew injector “A” (see fig.7).
The adjustment of the reduced rate position is as follows (fig. 8):
Light the burner and turn the knob to reduced rate position.
Remove the knob “M” which is simply inserted onto tap stem.
Insert a small screwdriver “C” into the top shaft “F” and turn the bypass screw left or right until flame of
the burner is conveniently regulated to the low position.
Make sure that when turning quickly from “Full on” position
to reduced rate position that the burner does not extinguish.
5. INSTALLATION INSTRUCTIONS
FIG. 7
FIG. 8
BUTANE
28 - 30
225
90
1400
3100
62
1
ULTRA RAPID
PROPANE
37
222
90
1400
3100
62
NATURAL
20
295
121 Y
1400
3100
62
BUTANE
28 - 30
127
65
500
1750
32
4
SEMIRAPID
PROPANE
37
125
65
500
1750
32
REAR LEFT
NATURAL
20
167
97 Z
500
1750
32
BUTANE
28 - 30
102
58
500
1400
32
3
SEMIRAPID
PROPANE
37
100
58
500
1400
32
FRONT RIGHT
NATURAL
20
133
85 Y
500
1400
32
BUTANE
28 - 30
204
83
750
2800
41
2
RAPID
PROPANE
37
200
83
750
2800
41
NATURAL
20
267
117 S
750
2800
41
BUTANE
28 - 30
73
50
400
1000
30
5
AUXILIARY
PROPANE
37
71
50
400
1000
30
NATURAL
20
95
72 X
400
1000
30
BURNERS
N°
DESCRIPTION
GAS
NORMAL
PRESSURE
NORMAL
RATE
INJECTOR
DIAMETER
BY
PASS
NOMINAL HEAT
INPUT (W)
mbar
g/h
l/h
1/100 mm
MIN.
MAX.
1/100 mm