15
Installing the appliance
This appliance is to be built into a worktop 600mm deep providing the following minimum dis-
tances are maintained;
•
The edges of the hob must be a minimum distance of 50mm from rear wall and 200mm from side
wall and this area should be free of any combustible materials.
•
700 mm between the highest point of the hob surface (including the pan supports) and the under-
side of any horizontal surface directly above it.
• Extractor or cooker hoods should only be fitted above the hob in accordance with the manufactur
-
er’s instructions.
•
400mm between the level of the hob and the underside of the wall units adjacent to the hob in the
vertical orientation.
•
You must have a gap (in the horizontal orientation) of at least 25 mm and at most 74 mm
between the underneath of the appliance and any surface that is below it (such as an
isolation plate or an oven).
Partition
Installation above a unit with a drawer or door
The underside of the hob will become hot during prolonged use, the user must be protected from hot
surfaces on the underside of the hob.
If fitting the hob above drawers or cupboards, a partition panel (isolation plate) must be fitted
underneath the hob to the minimum dimensions as shown above.
With Glass hob
To prevent leakage of liquid between the frame of the hob and the worktop, place the adhesive seal
provided along the entire outer edge of the underside of the hob before assembly.
Содержание GHU 60 LPG Series
Страница 1: ...Belling GTG GHU 60 75 LPG Date 17 04 20 ...