29
INSTALLATION
Natural Gas
(the appliance test point is
located at the regulator)
The supplied regulator must be fitted
to the appliance inlet connection. Gas
pressure must be adjusted to 1.0 kPa when
approximately 50% of the burners are on
high flame.
Universal LPG
(the appliance test point is
located at the injector)
Gas pressure must be checked to confirm the
appliance operating pressure is 2.75kPa, the
appliance test point is the Semi-Rapid burner
injector as shown.
1. Disconnect power.
2. Light the auxiliary burner and set to high
flame. Ensure all other burners are off.
3. Zero manometer, then apply flexible
tubing to seal over the Semi-Rapid
burner injector, hold securely in place and
check the gas pressure by pressing the
corresponding burner control knob in, then turning to high flame position.
4. If the pressure is 2.75 kPa, reassemble the burner and perform the final checks as per this
instruction manual.
5. If the pressure is not 2.75 kPa, disconnect the appliance and check/adjust/ replace the LPG
cylinder regulator(s) as appropriate in accordance with AS/NZS 5601.
The Cooker must be installed and maintained by a suitably qualified gas registered technician in
accordance with current safety legislation.
WARNING:
Do not use a naked flame to check for gas leaks.
Testing the operation of the gas cooker
NOTE: You must test the cooker after installation, before you hand it over to the
customer. You must have a manometer and a connecting tube.
Checking gas supply
• Check the manometer zero point is correct.
• Connect the manometer to the cooker pressure test point. This is located on the regulator or
LPG inlet fitting.
• Turn on the gas supply and the electricity (if applicable) and try to ignite the gas.
NOTE: It will take additional time to light the gas for the first time as air needs to be
purged from the pipes.
• Check the operating pressure for the particular gas type (see table).
1 Test Point location
2 Gas inlet pipe
3 Elbow
4 Regulator
Patent 2015101170. For enquires contact
Gas Approval Consulting Pty Ltd
Glen Dimplex Australia licence 043 for
AGA 8792 G