background image

44

English

Installation instructions 

Keep the burner orifi ces unblocked

!

Figure 27:  Marble pebbles Vertical Bell Small Tunnel 3  CF/LF                       
 

Position natural gas and propane/butane burner

Important: 

 

Do not place any marble pebbles in front of the pilot light.

 

 

Make sure that the pilot light can burn freely over the main   

 

 

burner.

 

 

Keep the burner orifi ces unblocked

.

 
 

Only this way a proper ignition of the main burner is ensured.

Once the logs / marble pebbles have been positioned, replace the glass in the appliance, 
following the instructions in chapter 4: DISMANTLING

 / ASSEMBLING OF THE 

GLASS

1.7.6  Mounting fl ue gas restriction plate 

Depending on the length and shape of the concentric fl ue system and the chimney 

construction, you should, if indicated, fi t a restriction plate with a certain width (B) into 
the ceiling of the combustion chamber. 
To do this, see the set-up options as listed in fi gure 4 through 14.

Marble pebbles must not be placed 
next to the pilot light burner

 

Keep the burner 
orifi ces unblocked

!

Содержание VIEW BELL TOPSHAM 3 LF

Страница 1: ...Gas fires with closed combustion system This document is an essential part of your gas fire Read it carefully before installation and maintenance of the gas fire and keep it in a safe place Bellfires wishes you many cosy evenings with your new Bellfires gas fire Serial number Production date ...

Страница 2: ......

Страница 3: ...3 English Installation instructions BELLFIRES GAS FIRE WITH CLOSED COMBUSTION SYSTEM Vertical Bell Small Tunnel 3 CF Centre Fire VBST3 CF Vertical Bell Small Tunnel 3 LF Line Fire VBST3 LF ...

Страница 4: ... supplied with the appliance The complete documentation necessary for the installation of the appliance consists of 1 INSTALLATION INSTRUCTIONS MANUAL FOR MAINTENANCE 2 CONCENTRIC COMPONENTS SUITABLE FOR THE INSTALLATION OF A BELLFIRES GAS FIRE WITH CLOSED COMBUSTION 3 INSTRUCTIONS FOR USE MANUAL DAILY MAINTENANCE ...

Страница 5: ...istered installation engineer IMPORTANT CONTENTS Page 1 INSTALLATION INSTRUCTIONS 7 2 MAINTENANCE 47 3 FAULTS 49 4 DISMANTLING ASSEMBLING OF THE GLASS 50 5 DIAGRAM ELECTRICITY AND GAS 56 6 DIMENSIONS 57 7 TECHNICAL DETAILS REGULATIONS 67 8 REPLACEMENT PARTS LIST 71 9 DISPOSAL OF PACKAGING AND APPLIANCE 74 ...

Страница 6: ...6 English Installation instructions ...

Страница 7: ...with a Ø100 mm Ø150 mm or Ø130 mm Ø200 mm concentric connection for extracting the flue gases and supply of combustion air It is possible to install the gas fire with either a wall or roof outlet The roof connection must be carried out using the concentric flue system Ø100 mm Ø150 mm The fumes are exhausted naturally to the outside environment through the inner Ø100 mm pipe whereas the combustion air...

Страница 8: ...n NL Jeremias TWIN GAS System The gas fire in combination with the concentric flue system Ø100 mm Ø150 mm and or Ø130 mm Ø200 mm rigid and or flexible for the brand types mentioned above has been approved in accordance with the European CE norm for gas appliances and may therefore be used only with these systems The permitted components for these systems are listed in instructions enclosed CONCENTRIC...

Страница 9: ... mm 1 4 OPTIONS AND ACCESSORIES The following options and accessories can be supplied by your dealer N B If any part is missing please contact your dealer 1 3 INCLUDED Set documentation Installation instructions Manual for maintenance Instructions for Concentric Components Instructions for use Manual daily maintenance Attributes Ceramic log set or marble pebbles white or marble pebbles grey Hook f...

Страница 10: ...ction exit grid white 145 x 145 mm 304040 4x Hose clamp Ø125 mm 329874 Set carrying brackets 2 pieces 3 Bellfires M G concentric flue system 3 Poujoulat DUOGAS concentric flue system 3 Ontop Metaloterm US concentric flue system 3 Jeremias STB H TWIN concentric flue system 3 Jeremias TWIN GAS concentric flue system Please refer to the instructions enclosed CONCENTRIC COMPONENTS SUITABLE FOR THE INSTALLAT...

Страница 11: ...r correct operation Roof mounted outlet Figure 1 Roof mounted outlet This must be positioned at least 0 5 m from the roof edge the apex of the roof can be disregarded Wall mounted outlet Figure 2 Wall mounted outlet This must be positioned at least 0 5 m from the corner of the building the roof overhang the rain gutter balconies etc unless the exhaust construction extends to at least the face of t...

Страница 12: ... an occupied room a toilet or a bathroom B A heating air supply when the supply flows through an occupied room C A window that can be opened and that is near an occupied room a toilet or a bathroom Roof mounted outlet To avoid adverse effects Distance outlet A B or C At the same roof level 3 m At a different roof level 1 m At a lower positioned wall 1 m At a higher sloping surface 3 m If the requir...

Страница 13: ...2 m if the distance from the facing wall is less the criteria detailed for On a wall general apply Enquire at your local gas company for the regulations relating to outlets positioned opposite each other and outlet s in facade s that form an angle These minimum distances do not apply if there is an obstruction between the outlet and A B and C that protrudes at least 0 5 m from the wall and has a l...

Страница 14: ...er walls approx 150 C no flammable materials may be located or used in the vicinity of the flue system The complete flue system must therefore be sleeved with a heat resistant material after assembly Ventilate the covered concentric flue by fitting a grid near the floor and ceiling on each floor Do not insulate the concentric flue Use the universal wall floor support Ø150 mm to attach the covering of the c...

Страница 15: ...ions see 1 6 2 Assemble restriction plate Appliance Distance Y Concentric Concentric min max connection connection on appliance is on appliance is Ø100 Ø150 mm Ø130 Ø200 mm 2 0 4 0 m Width Width B 30 mm B 65 mm Vertical Bell Small Tunnel 3 4 0 12 0 m Width Width B 40 mm B 80 mm RIGID CONCENTRIC FLUE Ø100 mm Ø150 mm SYSTEM CONNECTION POSSIBILITIES Appliance Concentric flue connection Ø100 Ø150 mm or...

Страница 16: ...GTH OF THE ROOF OR WALL TERMINATION 16 23 Y2 X 10 11 12 13 14 15 Y1 4 1 28 23 23 17 24 100 Item descriptions see 1 6 2 Assemble restriction plate Appliance Distance Y1 Distance X Distance Y1 Y2 Concentric Concentric min max min max min max connection connection on appliance is on appliance is Ø100 Ø150 mm Ø130 Ø200 mm Vertical Bell 1 0 11 0 m 0 3 0 m 1 0 11 0 m Width Small Tunnel 3 B 40 mm ...

Страница 17: ...30 10 11 12 13 Y Item descriptions see 1 6 2 Assemble restriction plate Appliance Distance Y Concentric Concentric min max connection connection on appliance is on appliance is Ø100 Ø150 mm Ø130 Ø200 mm 2 0 4 0 m Width Width B 30 mm B 65 mm Vertical Bell Small Tunnel 3 4 0 12 0 m Width Width B 40 mm B 80 mm Appliance Concentric flue connection Ø100 Ø150 mm or Ø130 Ø200 mm FLEXIBLE CONCENTRIC FLUE Ø...

Страница 18: ...o 1 ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION Y2 Y1 10 11 12 13 45 X Y3 32 18 30 29 5 7 29 26 25 23 28 4 1 100 Item descriptions see 1 6 2 Assemble restriction plate Appliance Distance Y1 Distance X Distance Y1 Y2 Y3 Concentric Concentric min max min max min max connection connection on appliance is on appliance is Ø100 Ø150 mm Ø130 Ø200 mm Vertical Bell 1 0 11 0 m 0 3 0 m 1 0 1...

Страница 19: ...LUDE THE LENGTH OF THE ROOF OR WALL TERMINATION Y 7 6 8 18 32 31 29 30 29 26 29 27 28 29 4 1 100 Item descriptions see 1 6 2 Assemble restriction plate Appliance Distance Y Concentric Concentric min max connection connection on appliance is on appliance is Ø100 Ø150 mm Ø130 Ø200 mm 2 0 4 0 m Width Width B 30 mm B 65 mm Vertical Bell Small Tunnel 3 4 0 12 0 m Width Width B 40 mm B 80 mm ...

Страница 20: ...ways at least 2 to 1 ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION Y3 Y2 Y1 X 45 6 8 7 31 29 32 18 30 29 26 29 27 28 29 4 1 100 Item descriptions see 1 6 2 Assemble restriction plate Appliance Distance Y1 Distance X Distance Y1 Y2 Y3 Concentric Concentric min max min max min max connection connection on appliance is on appliance is Ø100 Ø150 mm Ø130 Ø200 mm Vertical Bell 1 0 11 0 m ...

Страница 21: ...POSSIBILITIES and with wall outlet Ø100 mm Ø150 mm Figure 10 Horizontal wall termination Wall Termination Position 100 4 28 1 Y X 19 14 10 11 13 0 16 m Item descriptions see 1 6 2 Assemble restriction plate Appliance Distance Y Distance X Concentric Concentric min max min max connection on connection on appliance is appliance is Ø100 Ø150 mm Ø130 Ø200 mm 0 5 1 0 m 0 0 6 m Vertical Bell Small Tunne...

Страница 22: ... 0 16 m Appliance Concentric flue connection Ø130 Ø200 mm Assemble restriction plate Appliance Distance Y Distance X Concentric connection on min max min max appliance is Ø130 Ø200 mm 0 5 1 0 m 0 1 6 m Width B 40 mm Vertical Bell Small Tunnel 3 1 0 2 0 m 0 3 6 m Item descriptions see 1 6 2 RIGID CONCENTRIC FLUE Ø130 mm Ø200 mm SYSTEM CONNECTION POSSIBILITIES and with wall outlet Ø100 mm Ø150 mm ...

Страница 23: ... mm Assemble restriction plate Appliance Distance Y Distance X Concentric connection on min max min max appliance is Ø130 Ø200 mm Vertical Bell Small Tunnel 3 0 5 3 0 m 0 4 6 m Item descriptions see 1 6 2 100 4 128 1 Y X 19 114 110 111 113 0 25 m 123 Wall Termination Position RIGID CONCENTRIC FLUE Ø130 mm Ø200 mm SYSTEM CONNECTION POSSIBILITIES and with wall outlet Ø100 mm Ø150 mm ...

Страница 24: ...c connection on min max min max min max min max appliance is Ø130 Ø200 mm 0 0 5 m 0 0 5 m 0 5 1 0 m 0 0 6 m Vertical Bell 0 5 1 0 m 0 0 5 m 0 0 5 m 0 0 6 m Small Tunnel 3 1 0 3 0 m 0 1 0 m 0 5 2 0 m 0 0 6 m 1 0 3 0 m 0 3 0 m 1 0 3 0 m 0 0 6 m Item descriptions see 1 6 2 110 111 113 128 4 1 114 14 114 110 113 110 111 113 100 19 0 16 m Y2 X2 Y1 X1 Wall Termination Position RIGID CONCENTRIC FLUE Ø130...

Страница 25: ...ID CONCENTRIC FLUE Ø130 mm Ø200 mm SYSTEM CONNECTION POSSIBILITIES and with wall outlet Ø130 mm Ø200 mm Assemble restriction plate Appliance Distance Y Distance X Concentric connection on min max min max appliance is Ø130 Ø200 mm 0 0 5 m 0 0 6 m Vertical Bell Small Tunnel 3 0 5 3 0 m 0 8 6 m Item descriptions see 1 6 2 4 128 1 Y X 119 114 110 111 113 0 25 m 123 Wall Termination Position ...

Страница 26: ...ing to the European CE norm for gas appliances and may therefore be used only with these components The components of the concentric flue system of Bellfires Muelink Grol System Poujoulat DUOGAS System Ontop Metaloterm US System Jeremias STB H Twin System STB Schoorsteen Techniek Brummen NL Jeremias TWIN GAS System may not be used together in one installation Check whether the wall or roof terminati...

Страница 27: ...convection top plate and convection set 1x or 2x consideration should be given to the openings at approximately 1 meter above the appliance for the warm air exiting grids 1 7 POSITIONING THE APPLIANCE Important The fireplace is constructed on a sufficiently solid floor that can bear the weight of the appliance Ensure a free space of at least 1 cm between the bottom of the appliance and the floor Ensur...

Страница 28: ...ion Do not insulate the appliance Only the top and sides may be fitted with a strip of white loose insulation wool heat resistant to 1000 C width 15 cm max to protect the wall Do not use fibreglass or Rockwool or any other sort of insulating material These emit a pungent odour This is considered extremely unpleasant They may also cause discolouring of the column Flammable materials such as curtains ...

Страница 29: ...pening appliance convection air 2 Inlet opening grate chimney breast convection air 3 Natural convection in the chimney breast 4 Outlet opening grate chimney breast natural convection air 5 Outlet opening appliance convection air connection convection set 2x 6 Outlet opening grill convection set chimney breast convection air 2x 7 8 Concentric flue connection appliance Ø130 200 mm for a horizontal w...

Страница 30: ...kage 1 Inlet opening appliance convection air 2 Inlet opening grate chimney breast convection air 3 Natural convection in the chimney breast 4 Outlet opening grate chimney breast convection air 2x 5 Concentric flue connection appliance Ø100 150 mm for a vertical roof outlet 6 Concentric flue system Ø100 150 mm for a vertical roof outlet 7 Built in operating unit with gas regulating block and receive...

Страница 31: ...the floor of the combustion chamber The floor of the combustion chamber can be reached after the window and the grill around the burner have been removed see chapter 4 Using an Allenkey no 5 the appliance can be adjusted to the required height Position 4 protecting covers Protecting cover Adjustable feet seen from the bottom Adjust height with Allenkey no 5 of the appliance Press the 4 protecting co...

Страница 32: ...s outside the appliance the gas pipe must lead to where the operating unit built in the gas regulating block and the receiver assembly are fitted The appliance may not be installed in a flammable wall Attach the appliance to the side walls with 2 wedge bolts Use the adjustable mounting brackets at the top of the appliance for this 2x Mounting bracket ...

Страница 33: ...bled Disconnect the bracket with the gas regulator block and receiver from the appliance Carefully move the bracket with the gas regulator block receiver pipes and cables to the operating unit Mount the bracket at the bottom of the operating unit Important Take care that no pipes get damaged and no compression fittings come loose when moving the gas regulator block Prevent twisting the flexible pipe...

Страница 34: ...ession fittings and cable connectors can be temporarily disassembled After mounting carefully reassemble all pipes and cables Check afterwards all compression fittings for leaks and that all electric connections are properly connected Important Screw the thermocouple connection and thermocouple interrupter manually into the gas regulator block Afterwards carefully fasten a half turn with a spanner N...

Страница 35: ...ront burner Gas connection for gas valve to the rear burner Thermocouple interrupter connection Adjustment Screw Minimum Burner pressure Pilot light connection Figure 21 Gas regulator block Rear Pilot Gas Adjustment Screw Pierce the housing with a small screwdriver Adjustment Screw Maximum Burner pressure Motor knob Microswitch 8 Wire connecting cable receiver ...

Страница 36: ... connection yellow Piezo cable connection RESET button AUX Electrical connection for gas valve rear burner TC SW Thermocouple voltage current IN connection red 6 VDC Adapter connection option Connection 8 wire cable gas regulator block Connection for external operating option RESET button AUX Electrical connection for gas valve rear burner ...

Страница 37: ... the brickwork farther than the angle irons brackets keep in mind the thickness of any plastering Do not use masking tape on the appliance when installing and plastering Tape can damage the finish of the hearth Connect up the convection package if applicable The optional mantle iron is intended for supporting the brickwork above the hearth The mantle iron must rest on the brickwork on both sides so...

Страница 38: ...ebbles against the pilot light burner For that reason the main burner has a protective pilot light cowl Never remove this cowl Make sure that the pilot flame can burn at all times freely over the main burner Only in this way is proper ignition of the main burner ensured Ignoring these directions could lead to a dangerous situation Make sure that all burner orifices remains free at all times The burn...

Страница 39: ...Place the ceramic mat on the burner in such a way that the holes in the mat are in line with the burner openings 2 Remove the embers carefully from their packaging and spread them evenly over the burner mat and the grate around the burner 3 Distribute the vermiculite granules 50 gram evenly over the burner ...

Страница 40: ...st not be placed next to the pilot light burner Important make sure that all burner openings remain free Burner orifices which are not open could lead to a dangerous situation 4 Place the logs on the burner Appliance Natural gas burner Propane Butane burner see figure see figure Vertical Bell Small Tunnel 3 CF LF 24 25 Keep the burner orifices unblocked 5 Place the chips of wood around the burner ...

Страница 41: ...41 English Installation instructions Logs Log no u Log no v Log no w Log no x Log no y Log no z Log no Log no ...

Страница 42: ...on propane butane burner Keep the burner orifices unblocked Keep the burner orifices unblocked Figure 24 Log set Vertical Bell Small Tunnel 3 CF LF Position natural gas burner Embers must not be placed next to the pilot light burner Embers must not be placed next to the pilot light burner u y x z v ...

Страница 43: ...enings 2 Spread the pebbles over the whole burner bed burner and grid around the burner Make sure that the pilot light remains free Vertical Bell Small Tunnel 3 CF LF see figure 27 Figure 26 Marble pebbles set natural gas and propane butane burner IMPORTANT Open area in order to ensure free accessibility of the pilot flame to the burner Keep the burner orifices unblocked ...

Страница 44: ...in burner is ensured Once the logs marble pebbles have been positioned replace the glass in the appliance following the instructions in chapter 4 DISMANTLING ASSEMBLING OF THE GLASS 1 7 6 Mounting flue gas restriction plate Depending on the length and shape of the concentric flue system and the chimney construction you should if indicated fit a restriction plate with a certain width B into the ceilin...

Страница 45: ...estriction plate is mounted Use of the correct flue gas restriction plate will provide optimum efficiency flame effect and combustion Mounting an incorrect flue gas restriction plate can result in damage to the gas fire Figure 28 Positioning restriction plate Assembly restriction plate ...

Страница 46: ... short and blue yellow in colour These flames should gradually increase in height and become more yellow When all flames are yellow the gas fire has reached the correct temperature THE GAS FIRE IS NOW READY FOR USE Concentric flue connection appliance Ø130 200 mm Ø100 150 mm Restriction plate Horizontal wall outlet Roof mounted outlet Width B 30 mm Width B 40 mm B 40 mm Width B 50 mm B 50 mm Width B 6...

Страница 47: ...side panels if the appliance is fitted with these CAUTION If the appliance has anti reflective glass please follow the cleaning instructions in Chapter 4 of the Operating Instructions and Daily Maintenance Manual booklet Failure to follow these instructions may result in damage to the anti reflective glass After cleaning Carefully replace the embers vermiculite granules logs set or pebbles on and aro...

Страница 48: ...ressure Check if the overpressure hatches are correctly positioned and check if the packing seals properly under the hatches Check the complete concentric flue system including the outlet construction A camera can be used to inspect the whole length of the flue gas outlet and the combustion air intake Also check that all connections are secure ...

Страница 49: ...tacts in the thermo electrical system for example the thermocouple connection Batteries in receiver or remote control are flat 3 2 SAFETY MEASURES IN THE APPLIANCE 3 2 1 Thermo electric pilot light shut off The appliance is protected by means of a thermo electric pilot light shut off in the event of a gas escape from the main burner 3 2 2 Over pressure safety system The appliance is fitted with a pa...

Страница 50: ...t it falling forward 4 DISMANTLING ASSEMBLING OF THE GLASS 4 1 VERTICAL BELL SMALL TUNNEL 3 FLOATING FRAME Dismantling of the glass Vertical Bell Small Tunnel 3 Use the hook supplied see photo for Floating Frame opening the frame and the glass With the hook pull the thin metal spring strip on the top middle from the stud on the frame ...

Страница 51: ...51 English Installation instructions Detail of the stud middle Place paperboard on the chimney breast under the frame This helps prevent damage Dismantle the safety strip from the frame stud middle ...

Страница 52: ...t Check whether the frame is placed in the middle of the front Check whether the safety strip is securely fastened to the top of the frame middle The glass frame must fit tightly all round to the edge of the combustion chamber Check that the spring strip on the top remain in its proper place Carefully tilt the frame and the window Take hold of the frame and the glass forwards clamped together and p...

Страница 53: ... VERTICAL BELL SMALL TUNNEL 3 HIDDEN DOOR Dismantling of the glass Vertical Bell Small Tunnel 3 Hidden Door Use the hook to pull the frame at the top forward and hold the frame firmly Use the hook supplied for opening the frame including glass ...

Страница 54: ...hen loosening the frame and after it has been loosened support it with your hand to prevent it falling forward Dismantle the safety strip from the frame With the hook pull the thin metal spring strip on the top middle from the stud on the frame ...

Страница 55: ...he glass The assembly of the glass takes place in reverse order Important Check whether the frame is properly positioned underneath in the 2 holes of the front Check whether the frame is placed in the middle of the front Check whether the safety strip is securely fastened to the top of the frame The glass frame must fit tightly all round to the edge of the combustion chamber Check that the spring s...

Страница 56: ...burner Pilot light gas pipe Thermocouple interruptor 8 Wire connecting cable Gas pipe Front burner Gas valve Rear burner AC power adapter 230 VAC option Button RESET Receiver with battery compartment for 4 AA batteries Connection cable option for external operating i a Domotica systems Thermo electrical cable TC Thermo electrical cable SW Double burner Perforation pattern Centre Fire double burner...

Страница 57: ...57 English Installation instructions 6 DIMENSIONS 6 1 VERTICAL BELL SMALL TUNNEL 3 6 1 1 VERTICAL BELL SMALL TUNNEL 3 2x Hidden Door ...

Страница 58: ...58 English Installation instructions 6 1 2 VERTICAL BELL SMALL TUNNEL 3 2x Floating Frame ...

Страница 59: ...59 English Installation instructions 6 1 3 VERTICAL BELL SMALL TUNNEL 3 1x Hidden Door 1x Floating Frame ...

Страница 60: ...60 English Installation instructions 6 1 4 VERTICAL BELL SMALL TUNNEL 3 1x Hidden Door 1x Hidden Door plus 7 cm ...

Страница 61: ...61 English Installation instructions 6 1 5 VERTICAL BELL SMALL TUNNEL 3 1x Hidden Door 1x Hidden Door plus 10 cm ...

Страница 62: ...k are located in the fire and can be accessed via the metal cover under the stone The gas fire does not have a separate operating unit 6 1 6 VERTICAL BELL SMALL TUNNEL 3 1x Hidden Door 1x Hidden Door plus 10 cm Steen With the high adjustable feet option the appliance can be installed till 350 mm above the floor ...

Страница 63: ...th the high adjustable feet option the appliance can be installed till 350 mm above the floor 6 2 VERTICAL BELL SMALL TUNNEL 3 Fitted with the options Convection top plate High adjustable feet 6 2 1 VERTICAL BELL SMALL TUNNEL 3 2x Hidden Door ...

Страница 64: ...64 English Installation instructions With the high adjustable feet option the appliance can be installed till 350 mm above the floor 6 2 2 VERTICAL BELL SMALL TUNNEL 3 2x Floating Frame ...

Страница 65: ...65 English Installation instructions 6 2 3 VERTICAL BELL SMALL TUNNEL 3 1x Hidden Door 1x Floating Frame With the high adjustable feet option the appliance can be installed till 350 mm above the floor ...

Страница 66: ...66 English Installation instructions OPERATING UNIT ...

Страница 67: ...tural gas G20 Nominal heat input 9 8 kW Gross calorific value Nominal heat output 7 5 kW Efficiency class 1 85 NOx class 5 Gas rate max 0 92 m3 s hr Supply pressure 20 0 mbar Burner pressure max Hot 13 6 mbar Burner pressure max Cold 12 9 mbar Burner pressure min 0 4 mbar Primary air inlet burner Rear 1x Ø7 0 mm Primary air inlet burner Front 1x Ø7 0 mm Gas regulator block remote control Mertik GV 6...

Страница 68: ... Convection package 3 kg Both burners at maximum Appliance is on temperature Both burners at maximum Appliance is cold Both burners at minimum Flue gas exhaust and combustion air supply Roof mounted outlet Concentric flue system Ø100 mm Ø150 mm Rigid and or flexible Horizontal wall outlet Concentric flue system Ø130 mm Ø200 mm Rigid With wall outlet depending on the flue configuration Ø100 mm Ø150 mm o...

Страница 69: ...r Butane G30 37 0 mbar Propane G31 37 0 mbar Burner pressure max Hot 10 5 mbar 29 0 mbar Burner pressure max Cold 9 9 mbar 29 0 mbar Burner pressure min 0 7 mbar 2 0 mbar Primary air inlet burner Rear 1x Ø8 0 mm 1x Ø20 0 corner mm 2x Ø5 0 mm Primary air inlet burner Front 1x Ø8 0 mm 1x Ø20 0 corner mm 2x Ø5 0 mm Gas regulator block remote control Mertik GV 60 Mertik GV 60 Main burner Line Fire 428...

Страница 70: ... Including all options 112 kg 112 kg Convection package 3 kg 3 kg Both burners at maximum Appliance is on temperature Both burners at maximum Appliance is cold Both burners at minimum Flue gas exhaust and combustion air supply Roof mounted outlet Concentric flue system Ø100 mm Ø150 mm Rigid and or flexible Horizontal wall outlet Concentric flue system Ø130 mm Ø200 mm Rigid With wall outlet depending ...

Страница 71: ... Main burner injector Natural gas Rear no 180 1x Ø1 80 mm 9 301928 Main burner injector Butane Propane Front no 130 1x Ø1 30 mm 10 335120 Main burner injector Butane Propane Rear no 95 1x Ø0 95 mm 11 333597 Gas regulator block GV 60 M10 Thermocouple connection 12 302122 3 8 male x Ø12 Compression fitting 13 302084 Nut Ø8 mm for burner supply GV 60 for front burner 14 302089 Olive Ø8 mm for burner s...

Страница 72: ...e Ø4 mm L 1500 mm Flexible Stainless steel 38 325750 Burner pipe Ø8 mm L 1500 mm Flexible Stainless steel 10 kW front burner 39 325750 Burner pipe Ø8 mm L 1500 mm Flexible Stainless steel 10 kW rear burner 40 326055 Nut Ø8 mm compression elbow main burner 41 326054 Olive Ø8 mm compression elbow main burner 42 331085 Glass Vertical Bell Small 3 Tunnel Hidden Door 796 x 524 x 4 mm 43 331084 Glass Ve...

Страница 73: ... set white set grey Set Log no Art no O 332200 Vertical Bell Small Tunnel 3 1 331357 1x 2 331358 1x 3 331359 4 331360 1x 6 331362 1x 7 331363 8 331364 5 331361 1x 3 pieces xxxxxx 1x Bag 125 gr 301863 2x Bag 50 gr 332583 1x Bag 2 5 kg 310937 2x Bag 2 5 kg 325758 2x Chips of Embers with Vermiculite no 4 wood set Glow effect black Anthracite filtered ...

Страница 74: ...e Cardboard Wood Plastic Paper Such materials must be disposed of responsibly in line with local regulations Batteries should be disposed of as chemical waste Batteries must be disposed of responsibly in line with local regulations The authorities or fitter can provide you with information on responsible disposal of obsolete appliances ...

Страница 75: ...75 English Installation instructions ...

Страница 76: ...02 230719 337121 Your Bellfires dealer ...

Отзывы: