INSTRUCTIONS FOR USE &

MANUAL DAILY MAINTENANCE

VENTO CLASSIC LARGE 

Gas fi re with closed combustion system

Bellfi res wishes you many cosy evenings with your new Bellfi res gas fi re

This document is an essential part of your gas fi re. 

Read it carefully before use of the gas fi re and keep it in a safe place!  

Serial number:

Production date:

Содержание VENTO CLASSIC LARGE

Страница 1: ...Gas fire with closed combustion system Bellfires wishes you many cosy evenings with your new Bellfires gas fire This document is an essential part of your gas fire Read it carefully before use of the...

Страница 2: ......

Страница 3: ...3 Bellfires English Instructions for use BELLFIRES GAS FIRE WITH CLOSED COMBUSTION SYSTEM Vento Classic Large VCL...

Страница 4: ...4 Bellfires English Instructions for use...

Страница 5: ...5 Bellfires English Instructions for use CONTENTS Page 1 WARRANTY TERMS 7 2 INSTRUCTIONS FOR USE 9 3 USING THE APPLIANCE FOR THE FIRST TIME 20 4 DAILY MAINTENANCE 20 5 ANNUAL MAINTENANCE 21...

Страница 6: ...6 Bellfires English Instructions for use...

Страница 7: ...plicable legal provisions Article 2 Warranty conditions 2 1 Should you wish to claim under the warranty please contact your Bellfires dealer 2 2 Complaints should be reported as quickly as possible af...

Страница 8: ...ass cord thermocouple and the interior of the combustion chamber a similar guarantee is given until after the first burning Article 6 Liability 6 1 A claim granted by Interfocos B V under this warrant...

Страница 9: ...times freely over the main burner Only in this way is proper ignition of the main burner ensured Ignoring these directions could lead to a dangerous situation Do not place flammable objects within 100...

Страница 10: ...r added to Do not place easily flammable materials such as nylon clothing or flammable liquids in the vicinity of the gas fire Ensure at all times that children and other people who are not aware of t...

Страница 11: ...re powered by batteries Hand held transmitter 1x 9V battery Receiver 4x 1 5V battery type LR6 or AA Option 6V adapter 230 VAC Available from your fitter Note Hand held transmitter and receiver are not...

Страница 12: ...OFF to return to mode Important Setting up signal code before using the appliance for the first time Before the appliance can be used the receiver must first learn the hand held transmitter s signal c...

Страница 13: ...hand held transmitter is pressed except the SET button the transmission symbol appears on the screen The receiver confirms the transmission with an audio signal Operating day temperature thermostat Ap...

Страница 14: ...e appliance works thermostatically at the pre set stopping times P1 and P2 and the room temperature is automatically regulated to the pre set night temperature In order to allow the appliance to regul...

Страница 15: ...ch on the gas control block to the I position Turn the operating knob on the gas control block to the ON position Switch the hand held transmitter to the position On the hand held transmitter press th...

Страница 16: ...t beeps Ignition of the pilot light and main burner failed Possible cause air in the pilot light pipe Important If the pilot flame goes out then wait for at least 5 minutes before repeating the above...

Страница 17: ...uding the pilot light Press the O I switch on the gas control block to the O position This conserves battery life If the appliance is not to be used for some time please close the gas supply valve in...

Страница 18: ...nd of the compartment Close the cover and place the receiver back in its holder If the batteries are inserted incorrectly the electronics or drive may be irreparably damaged Only replace the batteries...

Страница 19: ...efore repeating the above procedure Move the operating knob to the ON position Depending on the position of the motor knob the burner will either ignite or not By turning the motor knob anti clockwise...

Страница 20: ...nd ceiling It is therefore very important to ensure that the room in which the appliance is located is sufficiently ventilated Regularly remove any dust deposits from behind the white panel door opera...

Страница 21: ...e complete concentric flue system where possible and the outlet are cleaned and inspected annually by a recognised fitter gas specialist The safe operation of the appliance will thus remain guaranteed...

Страница 22: ...22 Bellfires English Instructions for use...

Страница 23: ......

Страница 24: ...02 011112 331783 Your Bellfires dealer...

Страница 25: ...cument is an essential part of your gas fire Read it carefully before installation and maintenance of the gas fire and keep it in a safe place INSTALLATION INSTRUCTIONS MANUAL FOR MAINTENANCE VENTO CL...

Страница 26: ......

Страница 27: ...3 Bellfires English Installation instructions BELLFIRES GAS FIRE WITH CLOSED COMBUSTION SYSTEM Vento Classic Large VCL...

Страница 28: ...4 Bellfires English Installation instructions...

Страница 29: ...4 DISMANTLING ASSEMBLING OF THE GLASS THE REGULATOR AND BURNER 63 5 ELECTRICAL DIAGRAM 65 6 DIMENSIONS 66 7 TECHNICAL DETAILS REGULATIONS 67 8 REPLACEMENT PARTS LIST 69 9 DISPOSAL OF PACKAGING AND AP...

Страница 30: ...6 Bellfires English Installation instructions...

Страница 31: ...l or roof outlet The roof connection must be carried out using the concentric flue system 100 mm 150 mm The fumes are exhausted naturally to the outside environment through the inner 100 mm pipe where...

Страница 32: ...nk Grol system Poujoulat PGI system or Ontop Metaloterm US system has been approved in accordance with the European CE norm for gas appliances and may therefore be used only with these systems The per...

Страница 33: ...nd accessories can be supplied by your dealer Part no Accessorie 3 Bellfires M G concentric flue system See component summary 3 Poujoulat PGI concentric flue system See component summary 3 Ontop Metal...

Страница 34: ...t for correct operation Roof mounted outlet Figure 1 Roof mounted outlet This must be positioned at least 0 5 m from the roof edge the apex of the roof can be disregarded Wall mounted outlet Figure 2...

Страница 35: ...ing an occupied room a toilet or a bathroom B A heating air supply when the supply flows through an occupied room C A window that can be opened and that is near an occupied room a toilet or a bathroom...

Страница 36: ...all 2 m if the distance from the facing wall is less the criteria detailed for On a wall general apply Enquire at your local gas company for the regulations relating to outlets positioned opposite eac...

Страница 37: ...uter walls approx 150 C no flammable materials may be located or used in the vicinity of the flue system The complete flue system must therefore be sleeved with a heat resistant material after assembl...

Страница 38: ...OR WALL TERMINATION RIGID CONCENTRIC FLUE 100 mm 150 mm SYSTEM CONNECTION POSSIBILITIES Appliance Concentric flue connection 130 200 mm Item descriptions see 1 6 2 18 10 11 12 13 1 4 Y 28 16 17 16 24...

Страница 39: ...upwards is always at least 2 to 1 ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION Item descriptions see 1 6 2 16 23 Y2 X 10 11 12 13 14 15 Y1 4 1 28 23 23 17 24 100 Appliance Distance Y1...

Страница 40: ...ns see 1 6 2 100 1 4 28 32 18 23 25 26 29 7 5 29 30 10 11 12 13 Y Appliance Distance Y Assemble restriction plate min max 2 0 4 0 m Width B 65 mm Vento Classic Large 4 0 12 0 m Width B 90 mm ALL SIZES...

Страница 41: ...l to horizontal ratio or 45 upwards is always at least 2 to 1 Item descriptions see 1 6 2 Y2 Y1 10 11 12 13 45 X Y3 32 18 30 29 5 7 29 26 25 23 28 4 1 100 Appliance Distance Y1 Distance X Distance Y1...

Страница 42: ...when no chimney liners are present Flexible 100 mm 150 mm ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION Item descriptions see 1 6 2 Y 7 6 8 18 32 31 29 30 29 26 29 27 28 29 4 1 100 App...

Страница 43: ...Y3 X 2 1 Vertical to horizontal ratio or 45 upwards is always at least 2 to 1 ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION Item descriptions see 1 6 2 Y3 Y2 Y1 X 45 6 8 7 31 29 32 18...

Страница 44: ...OSSIBILITIES and with wall outlet 100 mm 150 mm Item descriptions see 1 6 2 Figure 10 Horizontal wall termination ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION Wall Termination Position...

Страница 45: ...nce Concentric flue connection 130 200 mm Item descriptions see 1 6 2 RIGID CONCENTRIC FLUE 130 mm 200 mm SYSTEM CONNECTION POSSIBILITIES and with wall outlet 100 mm 150 mm Wall Termination Position 1...

Страница 46: ...2 RIGID CONCENTRIC FLUE 130 mm 200 mm SYSTEM CONNECTION POSSIBILITIES and with wall outlet 100 mm 150 mm Wall Termination Position 100 4 128 1 Y X 19 114 110 111 113 0 25 m 123 Appliance Concentric fl...

Страница 47: ...flue pipe L 500 mm incl and Twin wall balanced flue elbow 90 incl and BELLFIRES ART ORDER NO 302289 302290 302291 302292 302297 Color Application RVS antr RIGID FLEX l l l l l l l l l l FIG NO DESCRI...

Страница 48: ...oof flashing for existing chimney or flat roof Horizontal wall termination kit L 600 mm horizontally adjustable incl and one set of wall spacer plates Stainless steel locking band 150 mm quick fasteni...

Страница 49: ...nce 150 mm flex Stainless steel locking band 150 mm For adapter 150 appliance 150 mm flex Screw fastening Stainless steel screws 3 5 mm x 9 5 mm For securing the flexible concentric flue Minimum 3 scr...

Страница 50: ...ES ART ORDER NO 302302 302303 321948 l l l l l l Color Application RVS antr RIGID FLEX Color RVS Stainless steel self colour polished antr Anthracite colour lacquer matt Adjustable roof flashing for a...

Страница 51: ...mm incl and Twin wall balanced flue pipe L 1000 mm incl and Adjustable length twin wall balanced flue pipe L 500 mm incl and Twin wall balanced flue elbow 90 incl and Twin wall balanced flue elbow 45...

Страница 52: ...ainless steel adapter piece 200 from fire to flexible 198 mm external rigid x 198 mm internal flex appliance 200 mm flex Stainless steel locking band 200 mm For adapter 200 appliance 200 mm flex Screw...

Страница 53: ...e pipe L 450 mm Twin wall balanced flue pipe L 950 mm Telescopic twin wall balanced flue pipe L min 390 mm max 640 mm Twin wall balanced flue elbow 90 Twin wall balanced flue elbow 45 POUJOULAT ART OR...

Страница 54: ...it L 140 mm Roof flashing suitable for a brick roof with a roof pitch of 15 30 Roof flashing suitable for a tiled roof with a roof pitch of 15 30 Roof flashing suitable for a brick roof with a roof pi...

Страница 55: ...ventilation grooves Set of ceiling finishing plates Fire stops suitable for a roof pitch of 0 10 Set of ceiling finishing plates Fire stops suitable for a roof pitch of 10 30 Set of ceiling finishing...

Страница 56: ...150 mm Adapter Bellfires 100 150 mm Poujoulat PGI 100 150 mm Appliance 100 150 Poujoulat PGI 100 150 Adapter Bellfires 130 200 mm Poujoulat PGI 100 150 mm Appliance 130 200 Poujoulat PGI 100 150 Conce...

Страница 57: ...12 114 115 POUJOULAT ART ORDER NO 37130403 37130404 37130405 37130429 37130441 37130421 DESCRIPTION Twin wall balanced flue pipe L 250 mm Twin wall balanced flue pipe L 450 mm Twin wall balanced flue...

Страница 58: ...eiling wall plate with spacers and ventilation grooves Set of ceiling finishing plates Fire stops suitable for a roof pitch of 0 10 Set of ceiling finishing plates Fire stops suitable for a roof pitch...

Страница 59: ...N Concentric pipe with inspection opening L 250 mm Roof support universal 200 mm Floor support universal 200 mm Adapter Bellfires 130 200 mm Poujoulat PGI 130 200 mm Appliance 130 200 Poujoulat PGI 13...

Страница 60: ...th 100 150 mm concentric connection Twin wall balanced flue pipe L 250 mm Twin wall balanced flue pipe L 500 mm Twin wall balanced flue pipe L 1000 mm Telescopic twin wall balanced flue pipe L min 60...

Страница 61: ...150 mm Adjustable roof flashing Roof pitch 20 45 with lead flashing Roof flashing plate for roof pitch 5 30 Roof flashing for existing chimney or flat roof Roof flashing Aluminium for existing chimne...

Страница 62: ...Locking band quick fastening Cover band screw fastening Wall strap adjustable Fitting bracket Set of ceiling finishing plates Fire stops Centring plates Roof support Renovation set Top of renovation...

Страница 63: ...band screw fastening Concentric pipe with inspection panel L 250 mm Concentric pipe with gauging orifice L 150 mm 90 concentric bend with inspection panel Rosette smooth 150 mm Wall plate large 150 mm...

Страница 64: ...200 mm concentric connection Twin wall balanced flue pipe L 250 mm Twin wall balanced flue pipe L 500 mm Twin wall balanced flue pipe L 1000 mm Telescopic twin wall balanced flue pipe L min 60 max 25...

Страница 65: ...Twin wall balanced flue elbow 30 Twin wall balanced flue elbow 15 Vertical roof termination kit L 375 mm incl Storm collar 150 mm Adjustable roof flashing Roof pitch 20 45 with lead flashing Roof flas...

Страница 66: ...luminium for existing chimney or flat roof Horizontal wall termination kit L 475 mm horizontally adjustable incl Locking band quick fastening Cover band screw fastening Wall strap adjustable Fitting b...

Страница 67: ...TION Roof support Renovation set Top of renovation set Bottom renovation set Locking band screw fastening Concentric pipe with inspection panel L 250 mm Concentric pipe with gauging orifice L 150 mm O...

Страница 68: ...nces have been approved in combination with the components of the concentric flue systems listed in this instruction book according to the European CE norm for gas appliances and may therefore be used...

Страница 69: ...e a free space of at least 1 cm between the bottom of the appliance and the floor Ensure that the temperature of the floor under and in front of the appliance can never rise above 85 C Make use of a t...

Страница 70: ...ll Do not use fibreglass or Rockwool or any other sort of insulating material These emit a pungent odour This is considered extremely unpleasant They may also cause discolouring of the column Flammabl...

Страница 71: ...nted after installation Because the control system is outside the appliance the gas pipe must lead to where the operating unit built in the gas regulating block and the receiver assembly are fitted Mo...

Страница 72: ...the operating unit using the two supports supplied Connect the supplied 8 12 4 mm stainless steel flexible gas pipe on one side under the burner plate with the compression coupling there The connectio...

Страница 73: ...lating block and receiver in operating unit 1 Gas regulating block 2 Gas supply connection 3 8 12 mm insertion 3 Burner piping connection 8 mm insertion 4 Thermocouple connection M 10x1 mm insertion 5...

Страница 74: ...be fitted Figure 17 Gas regulating block Remote control Side inlet Side outlet Bottom Outlet Bottom Inlet Inlet Pressure Tap Outlet Pressure Tap Thermo Unit Connection Minimum Rate Adjustment Screw M...

Страница 75: ...bottom of the control unit Make sure that you do not damage any of the piping or detach any compression couplings while doing this After you have done this check the compression couplings for leaks Ge...

Страница 76: ...pplied from the factory with three decorative elements for the exte rior of the fireplace 1x horizontal support girder 1x vertical post Right 1x vertical post Left Before building in the appliance car...

Страница 77: ...at In addition the posts should be at all time easily removable for maintenance to the appliance Bottom of hearth Up to level with the top of the support girder Note Ensure that there is a clearence o...

Страница 78: ...nce cannot be used for at least four weeks 1 7 4 Checking the gas connection After connection of the gas supply check that all connections are completely gas tight using soapy water or a leak tester 1...

Страница 79: ...ed to the appliance Replacement parts are available from your dealer Fitting may only be carried out by a qualified person Once the front has been removed along with the glass plate the embers can be...

Страница 80: ...56 Bellfires English Installation instructions Logs Log no Log no Log no Log no Log no Log no Log no Log no...

Страница 81: ...ish Installation instructions Keep the burner orifices unblocked Figure 21 Log set Vento Classic Large Position natural gas burner Embers must not be placed next to the pilot light burner Do not block...

Страница 82: ...t unblocked Note Small embers and their residue should not be scattered on the burner This can cause a blockage on the burner orifices 2 Place the logs around the burner see figure 22 Don t place any...

Страница 83: ...of the concentric flue system and the chimney construction you should if indicated fit a restriction plate with a certain width B into the ceiling of the combustion chamber To do this see the set up o...

Страница 84: ...installation visually check the gas flame When the fire is ignited the flames should be short and blue yellow in colour These flames should gradually increase in height and become more yellow When al...

Страница 85: ...lly replace the embers and logs set on and around the main burner according to the installation directions in this instruction booklet Do not place any embers or logs against the pilot light burner Ma...

Страница 86: ...ight is either dirty or defective Insufficient gas pressure Internal leak of the concentric flue system Thermocouple voltage is too low This is usually caused by insufficient heating of the thermocoup...

Страница 87: ...Lift the door slightly pull it forward and lower it carefully into the space below The door can now be removed from the front Use work gloves when removing the door 6 Remove the log set and the ember...

Страница 88: ...ll connections to the operating unit of the gas regulator block Thermocouple flexible pilot light pipe 4 mm and flexible burner pipe 8 mm Uncouple the piezo cable from the receiver You can now remove...

Страница 89: ...O I Switch RECEIVER Battery Compartment panel 4 AA Batteries cable 2 cable 1 red black SPARK SPARK SW TC SW TC GR SW MA MO Pilot ON OFF Switch Thermocurrent interrupter Block red Button Reset Motor k...

Страница 90: ...66 Bellfires English Installation instructions 6 DIMENSIONS 6 1 VENTO CLASSIC LARGE Operating unit Gas connection...

Страница 91: ...ic value Propane G31 10 0 kW Nominal heat output 9 0 kW 6 3 7 6 kW Efficiency class 2 75 2 75 NOx class 5 5 Gas rate max 1 20 m3 s hr Butane G30 860 gr hr Propane G31 710 gr hr Supply pressure 20 0 mb...

Страница 92: ...r 1x 9V block 1x 9V block Weight 190 kg 190 kg When the appliance has reached its thermal equilibrium Burner at maximum Appliance is cold Flue gas exhaust and combustion air supply Roof mounted outlet...

Страница 93: ...off nipple 4 mm GV 60 12 302067 Cable sw Receiver Thermocouple interrupter L 500 mm 13 302150 Switch with short length of cable to thermocouple interrupter and long length of cable tc L 500 mm to rec...

Страница 94: ...5 x 3 mm adhesive 34 319664 Black fibre glass tape 30 x 2 mm adhesive 35 323601 Fire clay interior 4 plates and grill part 36 323600 Fire clay exterior 2x posts and girder Appliance Log set Set Log no...

Страница 95: ...clude Cardboard Wood Plastic Paper Such materials must be disposed of responsibly in line with local regulations Batteries should be disposed of as chemical waste Batteries must be disposed of respons...

Страница 96: ...03 011112 331795 Your Bellfires dealer...