background image

INSTRUCTIONS FOR USE &

INSTALLATION INSTRUCTIONS

UNICA 200 L/R

UNICA 300

Gas fi re with open combustion system

Bellfi res wishes you many cosy evenings with your new Bellfi res gas fi re

This document is an essential part of your gas fi re. 

Read it carefully before use of the gas fi re and keep it in a safe place!    

Serial number:

Production date:

Содержание UNICA 200 L

Страница 1: ...ICA 300 Gas re with open combustion system Bell res wishes you many cosy evenings with your new Bell res gas re This document is an essential part of your gas re Read it carefully before use of the ga...

Страница 2: ......

Страница 3: ...r use Installation instructions CONTENTS Page 1 INSTRUCTIONS FOR USE 7 2 INSTALLATION INSTRUCTIONS 17 3 MAINTENANCE 28 4 FAULTS 29 5 ELECTRICAL DIAGRAM 30 6 DIMENSIONS 31 7 TECHNICAL DETAILS REGULATIO...

Страница 4: ...4 Bell res English Instructions for use Installation instructions...

Страница 5: ...applicable legal provisions Article 2 Warranty conditions 2 1 Should you wish to claim under the warranty please contact your Bell res dealer 2 2 Complaints should be reported as quickly as possible a...

Страница 6: ...as glass glass cord thermocouple and the interior of the combustion chamber a similar guarantee is given until after the rst burning Article 6 Liability 6 1 A claim granted by Interfocos B V under th...

Страница 7: ...a thermo electric pilot light shut off in the event of a gas escape from the main burner Additionally the gas re is tted with a thermal one way protection safety system This system shuts off the appli...

Страница 8: ...lect the desired position the burner will now continueously burn as an atmospheric burner until the setting is changed Both operating knobs can be used in combination If the appliance is equipped with...

Страница 9: ...By turning the thermostat knob to the required setting and or pushing the slider into a downward position the burner will now ignite 1 5 TURNING OFF THE FIRE Turn the thermostat knob to the ignition p...

Страница 10: ...he desired position of the knob and also the ame height are regulated by ultra sonic signals B A Figure 2 Operating switch model 400 1 7 2 Igniting the re Open the gas valve in the gas supply pipe to...

Страница 11: ...eps or by means of the cordless remote control continuous Turning knob B to the left in the direction of the big ame symbol increases the ame height to the right in the direction of the l symbol decre...

Страница 12: ...0 and Unica 300 400 Figure 5 4 x Connectors to gascontrols Changing batteries signal Temperature display C F Heating period P1 and P2 Time display Button High MAN Setting TIMER Setting TIME Button Low...

Страница 13: ...to MAN by pressing the TIMER button 1 7 7 Set the current time After connecting the batteries or when simultaneously pressing AUTO and TIMER the display ashes You are in SET mode Press to set the hour...

Страница 14: ...motor will turn the valve to pilot and there is no temperature control This minimizes battery consumption You may press AUTO to verify the set temperature and then press TIMER to return to timer mode...

Страница 15: ...release it from the contact holder Remove the batteries from the battery support Place the 4 new batteries of 1 5V type LR6 or AA in the battery support as indicated The pressure spring always agains...

Страница 16: ...the appliance is used Heating of these particles by the convection system of the appliance could lead to discoloration of the walls and ceiling It is therefore very important to ensure that the room i...

Страница 17: ...is more than 20 Pa 0 2 mbar then it is recommended to reduce it Before beginning the installation check that the details on the rating plate correspond to the gas type and pressure to which the appli...

Страница 18: ...ording to the regulations 1 NATURALLY VENTILATED HOUSE see Figure 6 The room in which the appliance is to be tted must have a non closable combustion air supply opening The minimum dimensions are deta...

Страница 19: ...e is to be tted must have a non closable combustion air supply opening The minimum dimensions are detailed in Technical Details Regulations at the rear of this manual see also Paragraph 2 4 point 2 Th...

Страница 20: ...al Details Regulations at the rear of this manual The air supply opening must be non closable 3 THERMOSTAT SENSOR The appliance is equipped with a thermostat sensor which is normally tted to the botto...

Страница 21: ...a new chimney The replace must be mounted on a concrete oor If there is no concrete oor it is es sential to re enforce the oorboards underneath with concrete Build in the re insert up to the top of th...

Страница 22: ...The operating hatch can be taken out if the left hinge pin is pulled from the frame by means of pointed pliers or unscrewing the left Phillips screw if there is one 3 Dismantling the front door and gl...

Страница 23: ...igure 8 Unica 200 L Figure 9 Unica 200 R Control unit Outer casing Operating hatch Door Flue spigot Front Cover plate Inner shell Combustion chamber Flue spigot Operating hatch Door Front Side cover C...

Страница 24: ...tom side If necessary loosen the electrical supply cable from the connector and guide the cable through the special openings to the wall socket on which during installation there must be no tension Sl...

Страница 25: ...sliding the control unit underneath the inner shell secure the light blue plug connectors of the security system For this purpose the wires need to be led outside left along the inner shell after whic...

Страница 26: ...tribute the vermiculite granules 1x 10 gram evenly over the burner not in front of the pilot light 2 Carefully remove the embers 2x 125 gram from the packaging and place them evenly on and around the...

Страница 27: ...front 7 FITTING THE OPERATING HATCH ES Fit the operating hatch on the right hand side of the opening Press the left hinge pin and position the hatch in the correct position or tighten the left Phillip...

Страница 28: ...nce consists of the following points Cleaning the main burner pilot light and ue exhaust Removing dust deposits using a vacuum cleaner Checking for possible leakages at the gas connections and ue join...

Страница 29: ...due to ue gas escape Malfunction of the security system Check by means of testing Insuf cient gas pressure Pilot light is dirty Thermocouple voltage too low This is usually caused by insuf cient heati...

Страница 30: ...RICAL DIAGRAM blue brown yellow green brown brown brown blue yellow green 1 Fanspeed controller convection fan 230 VAC 50 Hz 2 Convection fan 230 VAC 50 Hz 3 Thermostat Clickson set at 40 C 4 Earthed...

Страница 31: ...31 Bell res English Instructions for use Installation instructions 6 DIMENSIONS 6 1 UNICA 200 L Gas connection Gas connection Gas connection possibility bottom of the appliance...

Страница 32: ...32 Bell res English Instructions for use Installation instructions 6 2 UNICA 200 R Gas connection possibility bottom of the appliance Gas connection Gas connection...

Страница 33: ...33 Bell res English Instructions for use Installation instructions 6 3 UNICA 300 Gas connection possibility bottom of the appliance Gas connection Gas connection...

Страница 34: ...lass 2 80 2 80 NOx class 1 1 Gas rate max 0 74 m3 s hr 500 gr hr Supply pressure 20 0 mbar 37 0 mbar Burner pressure max Hot 10 0 mbar 29 0 mbar Burner pressure max Cold 9 0 mbar 29 0 mbar Burner pres...

Страница 35: ...control 8 302410 Receiver with cable 9 302411 Cable 10 305698 Main burner natural gas G20 G25 4x 8 5 11 305699 Main burner propane G31 8x 8 5 12 319743 Main burner injector natural gas no 105 13 32054...

Страница 36: ...controller 230 VAC 50 Hz 28 302154 Clickson 29 301617 Black bre glass cord 10 mm L 1620 mm 30 301595 Fibre glass tape 20 x 6 mm L 360 mm 31 301593 Black bre glass tape 15 x 3 mm adhesive 32 301612 Bla...

Страница 37: ...37 Bell res English Instructions for use Installation instructions...

Страница 38: ...38 Bell res English Instructions for use Installation instructions...

Страница 39: ......

Страница 40: ...Your Bell res dealer 02 011014 331059...

Отзывы: