The brickwork must be built up around the hearth. In connection with the hearth
expanding during burning: there must be at least 3 mm clearance on either side of the
appliance. Do not build up the brickwork farther than the top of the appliance (keep in
mind the thickness of any plastering!).
The appliance is supplied with a straight pressed steel lintel as option to allow installation
against a fl at wall or in a fi replace. The mantle iron is intended for supporting the brick-
work above the appliance. The mantle iron must rest on the brickwork on both sides so
that upward building is possible. The brickwork therefore must not rest on the fi replace;
there must be approx. 3 mm clearance in connection with the weight.
A heat-resistant sealing cord should be placed between the appliance and the lower
side of the lintel to allow vertical expansion of the appliance and to prevent cracking the
fi replace.