Страница 5: ...tallation engineer IMPORTANT CONTENTS Page 1 INTRODUCTION 7 2 INSTALLATION 15 3 ANNUAL MAINTENANCE 38 4 FAULTS 42 5 DISMANTLING ASSEMBLING OF THE GLASS THE REGULATOR AND BURNER 43 6 CONNECTING DIAGRAM...

Страница 6: ...6 Bellfires English Installation instructions...

Страница 7: ...rrespond to the gas type and pressure to which the appliance will be connected If an existing chimney is to be used please consult your installer first If the chimney was previously used for a wood or...

Страница 8: ...peration of the gas appliance are only in the vicinity of the appliance exclusively under supervision Use a fireguard to protect the people and children mentioned above against possible burns 1 3 BUIL...

Страница 9: ...pilot flame is to be replaced then only the original model should be applied This atmosphere protection the oxy stop pilot light is not a substitute for an independent mounted carbon monoxide detecto...

Страница 10: ...ica 2 70 334587 Fan set Unica 2 series UK Set consisting a convection fan 230 VAC 39 W cable and assembly material 3 Ambient lighting set Unica 2 series Set consisting of two lamps 230 VAC 2x 25 W cab...

Страница 11: ...which the appliance is to be fitted has non closable ventilation openings according the national and local applicable building regulations The minimum dimensions are detailed in Technical Details Reg...

Страница 12: ...d local applicable building regulations The minimum dimensions are detailed in Technical Details Regulations at the rear of this manual The flue gases must be extracted by means of a flue extraction f...

Страница 13: ...or flexible stainless steel pipe of 100 mm 4 or 5 minimum Top exit or 178 mm 7 minimum Rear exit An protective cap must be placed on top of the chimney to prevent rain entering Where it concerns a ne...

Страница 14: ...with a convection fan and or ambient lighting or AC Power adaptor there must be a wall socket with earth connection preferably at the right hand side of the appliance The socket should be accessible...

Страница 15: ...cm Position the appliance at least 12 cm above the floor height Not required with a non combustible floor Ensure that the temperature of the floor under and in front of the appliance can never rise a...

Страница 16: ...connection Only applicable if the appliance is provided with an convection fan and or ambient lighting or a AC Power adaptor During subsequent installation protect the gas piping against encasement by...

Страница 17: ...ght pressed steel lintel as option to allow installation against a flat wall or in a fireplace The mantle iron is intended for supporting the brick work above the appliance The mantle iron must rest o...

Страница 18: ...stone or heat resistant plating you should follow the supplier s instructions For further positioning instructions See Paragraph 2 1 3 Check that all connections are completely gas tight using soapy w...

Страница 19: ...on the appliance into the fire place Push the aluminium or stainless steel pipe into the flue spigot of the appliance For further installation procedures refer to paragraph 2 1 1 and 2 1 3 Unlined ins...

Страница 20: ...emoval of the top exit flue connection piece Disassemble the top flue outlet connection piece from the inside of the appliance a Disassemble first the baffle plate at the top of the combustion chamber...

Страница 21: ...e top of the combustion chamber by loosening the screws around and take it out c Disassemble the plate with flue outlet connection piece by loosening the bolts on the outer edge Do not fully unscrew t...

Страница 22: ...22 Bellfires English Installation instructions 3 Removal of the rear exit flue opening cover plate Disassemble the rear exit flue opening cover plate from the back of the appliance...

Страница 23: ...e Unlined installation UK only From the ceiling of the fireplace opening till the roof terminal Make sure that the existing flue has a diameter of minimal 180 mm 7 Place an insulated aluminium or flex...

Страница 24: ...24 Bellfires English Installation instructions For further installation procedures refer to paragraph 2 1 1 and 2 1 3...

Страница 25: ...25 Bellfires English Installation instructions Minimal clearance Minimal clearance Gas Unlined installation UK only Minimum installation sizes All sizes in mm...

Страница 26: ...ust be installed in the vicinity of the appliance that must remain accessible at all times The Netherlands placement of the appliance s gas tap is permitted in the meter cupboard U K Ireland the appli...

Страница 27: ...nd take the plate out b Disassemble after this the draft diverter from the top of the combustion chamber by loosening the screws around and take it out c Disassemble the plate with flue outlet connect...

Страница 28: ...28 Bellfires English Installation instructions 5 Flue...

Страница 29: ...pipes The power supply can now be reconnected to the wall socket Only applicable if the appliance is equipped with a convection fan ambient lighting and or a AC power adaptor Prevent the power cord to...

Страница 30: ...t light burner Make sure that the pilot flame can burn at all times freely over the main burner Only in this way is proper ignition of the main burner ensured Ignoring these directions could lead to a...

Страница 31: ...et chips of wood embers 1 Place the ceramic mat on the burner in such a way that the holes in the mat are in line with the burner openings 2 Remove the embers carefully from their packaging and spread...

Страница 32: ...must not be placed next to the pilot light burner Important make sure that all burner openings remain free Burner orifices which are not open could lead to a dangerous situation 3 Place the logs on t...

Страница 33: ...33 Bellfires English Installation instructions Logs Log no Log no Log no Log no Log no Log no Log no Log no...

Страница 34: ...0 Position natural gas burner Figure 4 Log set Unica 2 70 Position propane butane burner Embers must not be placed next to the pilot light burner Embers must not be placed next to the pilot light burn...

Страница 35: ...the burner openings 2 Spread the shingles over the whole burner bed burner and grid around the burner Make sure that the pilot light remains free Unica 2 70 see figure 6 IMPORTANT Open area in order t...

Страница 36: ...that the pilot light can burn freely over the main burner Keep the burner orifices unblocked Only this way a proper ignition of the main burner is ensured Once the logs marble shingles have been posi...

Страница 37: ...ne of the tests dis connect the appliance immediately and ask your dealer for advice 11 Assembling the glass door Assemble the door including the glass by hooking it in at the top and then screwing it...

Страница 38: ...t off immediately Glass cleaner liquid in the sealing of the door can cause dissolving of the black border on the inside of the glass It will become very spotty and can t be repaired If the glass is b...

Страница 39: ...ir supply openings in the appliance Dust can be removed using a vacuum cleaner Clean the combustion air intake openings exterior grille Convection air appliance convection fan option Check the convect...

Страница 40: ...the new light bulbs left and right in the ceramic fittings Use only the Bellfires Fire Glow light bulb Turn the Fire Glow light bulbs completely into the socket Assemble the aluminum caps Plug the un...

Страница 41: ...and oil lamps in the air of your home Heating of these particles through the convection system of the appliance may lead to discoloration of walls and ceiling Therefore always ventilate the room suffi...

Страница 42: ...s escape from the main burner 4 2 2 Atmosphere protection flue exhaust protection oxy stop pilot light Also the appliance is fitted with an atmosphere protection facility This is an oxy stop pilot fla...

Страница 43: ...ner Avoid damaging the walls 6 Dismantling pilot light Dismantling pilot light Unscrew the 2 screws next to the pilot light Remove the wind guard You can now dismantle the complete oxy stop pilot ligh...

Страница 44: ...t Interrupter Block black Convection fan option Connecting cable 230 VAC Plug with Earth connection Module option 5 Wire Connecting Cable Button RESET red yellow red Ambient lighting option Ignition p...

Страница 45: ...45 Bellfires English Installation instructions 7 DIMENSIONS 7 1 UNICA 2 70 Lined flue 4 or 5 Top flue opening 100 106 mm GAS factory fitted GAS Option GAS both sides and bottom Option GAS bottom...

Страница 46: ...46 Bellfires English Installation instructions 7 2 UNICA 2 70 Lined flue 4 or 5 Top flue opening 100 106 mm With fan option GAS factory fitted GAS Option GAS bottom Option GAS both sides and bottom...

Страница 47: ...Bellfires English Installation instructions GAS factory fitted GAS Option GAS bottom Option GAS both sides and bottom 7 3 UNICA 2 70 U K only Unlined Flue 7 180 mm Minimal Rear flue opening 252 x 34 5...

Страница 48: ...s English Installation instructions GAS factory fitted GAS Option GAS bottom Option GAS both sides and bottom 7 4 UNICA 2 70 U K only Unlined Flue 7 180 mm Minimal Rear flue opening 252 x 34 5 mm With...

Страница 49: ...5 7 6 5 kW Efficiency class 2 80 2 80 NOx class 5 5 Gas rate max 0 65 m3 s hr Butane G30 590 gr hr Propane G31 530 gr hr Supply pressure 20 0 mbar Butane G30 30 0 mbar Propane G31 37 0 mbar Burner pre...

Страница 50: ...VAC 50 Hz 230 VAC 50 Hz Electricity consumption 90 W max IP 20 90 W max IP 20 Weight 54 kg 54 kg When the appliance has reached its thermal equilibrium Burner at maximum Appliance is cold UK only The...

Страница 51: ...0 mm 12 333598 Hand held transmitter Display Temperature and two programmes 13 333600 Receiver GV 60 EU 14 302068 8 Wire connecting cable Receiver L 500 mm 15 325640 Piezo ignition cable 2 8 x 0 8 mm...

Страница 52: ...o 333645 Unica 2 70 Marble pebbles set white 1 331357 1x 2 331358 1x 3 331359 4 331360 1x 6 331362 2x 7 331363 8 331364 5 331361 Bag 2 5 kg 310937 1x Marble pebbles set grey Bag 2 5 kg 325758 1x Chips...

Страница 53: ...clude Cardboard Wood Plastic Paper Such materials must be disposed of responsibly in line with local regulations Batteries should be disposed of as chemical waste Batteries must be disposed of respons...

Страница 54: ...54 Bellfires English Installation instructions...

Страница 55: ......

Страница 56: ...03 150913 333902 Your Bellfires dealer...