background image

P

Preparation manual

Box Gas Panorama 45/45 MF

Serial number:

Production date:

Содержание Smart Bell Panorama 45/45 MF

Страница 1: ...P Preparation manual Box Gas Panorama 45 45 MF Serial number Production date...

Страница 2: ...hout the prior written permission of Barbas Bellfires BV This document could contain technical inaccuracies or typographical errors Barbas Bellfires BV reserves the right to revise this document from...

Страница 3: ...ssibilities for a concentric flue system with a roof outlet 10 4 4 2 Possibilities for a concentric flue system with a wall outlet 16 5 Technical specification 17 5 1 Dimensions Box Gas Panorama 45 45...

Страница 4: ...w a typical setup The illustrations are for instructional use only 1 1 How to work with this document 1 Make yourself familiar with the structure and content of the document 2 Read the safety chapter...

Страница 5: ...The in ner pipe is used as flue gas channel and the space be tween the inner pipe and the outer pipe is used as combustion air channel Flue gas channel The flue gases from the appliance flow through t...

Страница 6: ...cified in this manual and the related documents Only use the following brands for the installation of the concentric flue system Manufacturer system Bellfires Muelink Grol system Poujoulat DUOGAS syst...

Страница 7: ...Make sure that there is a wall socket with earth connection nearby the appliance The socket must be accessible at all times The powercable 0 5 m is coming from the rear of the appliance If the wall of...

Страница 8: ...tance between the items and the wall outlet On a wall where the item services a living space other than that of the owner of the fireplace Do not install the wall outlet under an item On a wall Below...

Страница 9: ...cated Do not insulate the concentric flue The parts that are required for the installation of the concentric flue system are numbered in the illustrations and refer to the part list in 6 Use the unive...

Страница 10: ...roof outlet Rigid concentric flue systems 4 28 100 1 10 11 12 13 23 24 17 16 24 18 16 Y Y min max Flue gas restriction plate width Concentric connection on the appliance is 100 150 mm 2 0 4 0 m 30 mm...

Страница 11: ...Y1 min max X min max Y1 Y2 min max Flue gas restriction plate width Concentric connection on the appliance is 100 150 mm 1 0 11 0 m 0 3 0 m 1 0 11 0 m Caution Make sure that Y1 Y2 is at least 2 times...

Страница 12: ...23 25 18 10 11 12 13 Y Y min max Flue gas restriction plate width Concentric connection on the appliance is 100 150 mm 2 0 4 0 m 30 mm 4 0 12 0 m 40 mm Roof outlet using an flexible 100 mm liner in a...

Страница 13: ...n max Flue gas restriction plate width Concentric connection on the appliance is 100 150 mm 1 0 11 0 m 0 3 0 m 1 0 11 0 m Caution Make sure that Y1 Y2 Y3 is at least 2 times larger than X Roof outlet...

Страница 14: ...Flue gas restriction plate width Concentric connection on the appliance is 100 150 mm 2 0 4 0 m 30 mm 4 0 12 0 m 40 mm Roof outlet using an flexible 100 mm liner and flexible 150 mm liner in an existi...

Страница 15: ...striction plate width Concentric connection on the appliance is 100 150 mm 1 0 11 0 m 0 3 0 m 1 0 11 0 m Caution Make sure that Y1 Y2 Y3 is at least 2 times larger than X Roof outlet using an flexible...

Страница 16: ...n the figure The centre of the inner pipe must be positioned above the centre of the outer pipe Rigid concentric flue systems 19 1 10 11 12 13 4 28 100 14 Y 0 16 m X Y min max X min max Flue gas restr...

Страница 17: ...5 5 Technical specification 5 1 Dimensions Box Gas Panorama 45 45 Technical specification Box Gas Panorama 45 45 17...

Страница 18: ...5 5 2 Dimensions Box Gas Panorama 45 45 with Storage module Technical specification 18 Box Gas Panorama 45 45...

Страница 19: ...45 45 with Support frame 5 4 Dimensions of the restriction plate Width of the delivered flue restriction plates in mm Concentric flue connection 100 150 Roof mounted outlet 30 40 50 65 Technical speci...

Страница 20: ...ter The guarantee on the appliance lapses if it is installed fully or partially with other components or a different flue system The concentric flue 100 mm 150 mm systems can be used with either a new...

Страница 21: ...in wall balanced flue pipe L 500 mm 11 302290 Twin wall balanced flue pipe L 1000 mm 12 302291 Telescopic twin wall balanced ue pipe L min 325 max 440 mm 13 302292 Adjustable length twin wall balanced...

Страница 22: ...20 45 with lead ashing 18 302213 Roof ashing for existing chimney or at roof 19 302296 Horizontal wall termination kit L 600 mm adjustable including a set of wall spacer plates 20 302293 Stainless ste...

Страница 23: ...Stainless steel adapter piece 150 re to exible 148 mm external rigid x 148 mm internal ex appliance 150 mm ex 28 302217 Stainless steel locking band 150 mm For adapter 150 appliance 150 mm ex Screw f...

Страница 24: ...tric bend with in spection panel 36 321948 Universal wall oor support 150 mm Color rvs Stainless steel self color polished antr Anthacite color lacquer matt Adjustable roof flashing for a slope 45 can...

Страница 25: ...ced flue pipe L 450 mm 11 34100405 Twin wall balanced flue pipe L 950 mm 12 34100429 Telescopic twin wall balanced ue pipe L min 390 max 640 mm 14 34100441 Twin wall balanced ue el bow 90 15 34100421...

Страница 26: ...oof pitch of 15 30 17 45150172 Roof ashing suitable for a brick roof with a roof pitch of 30 45 17 45150173 Roof ashing suitable for a tiled roof with a roof pitch of 30 45 18 45150169 Roof ashing for...

Страница 27: ...28 Set of ceiling nishing plates Fire stops suitable for a roof pitch of 40 50 34 34100407 Concentric pipe with inspec tion opening L 250 mm 36 45150165 Roof support universal 150 mm 36 45150081 Floor...

Страница 28: ...l balanced ue pipe L 250 mm 10 US 50 10 Twin wall balanced flue pipe L 500 mm 11 US 100 10 Twin wall balanced flue pipe L 1000 mm 12 USPP 10 Telescopic twin wall balanced ue pipe L min 60 max 250 mm 1...

Страница 29: ...10 Adjustable roof ashing Roof pitch 20 45 with lead ashing 17 USDH 10 Roof ashing plate for roof pitch 5 30 18 USDP 10 Roof ashing for existing chimney or at roof 18 USDPAL 10 Roof ashing Aluminium F...

Страница 30: ...MB 10 Wall strap adjustable 23 USEB 10 Fitting bracket 24 USCP 10 Set of ceiling nishing plates Fire stops Centring plates 24 USDQ 10 Roof support 25 USSAN 10 Renovation set 25 USSAN1 10 Top of renova...

Страница 31: ...panel L 250 mm 34 USEM 10 Concentric pipe with gauging ori ce L 150 mm 35 USBI 10 90 concentric bend with in spection panel USR 10 Rosette smooth 150 mm USMPG 10 Wall plate large 150 mm square 300 mm...

Страница 32: ...mm 10 ATWINL 15 100 150 Twin wall balanced flue pipe L 250 mm 12 H TWIN 742 100 150 Telescopic twin wall balanced ue pipe L min 1100 max 1400 mm 12 H TWIN 467 100 150 Telescopic twin wall balanced ue...

Страница 33: ...100 150 Twin wall balanced ue el bow 45 14 ATWIN 60 100 150 Twin wall balanced ue el bow 90 14 ATWIN 60F 100 150 Twin wall balanced ue el bow 90 Short Especially for connection to a wall termi nation...

Страница 34: ...ashing for roof pitch 30 with lead ashing and storm collar 17 ATWIN 60DD 100 150 Roof ashing for roof pitch 45 with lead ashing and storm collar ATWIN 307 100 150 Storm collar 24 ADBL DW 100 150 Set o...

Страница 35: ...nspection panel with cover cap and condensation opening ATWIN 465 100 150 Adapter H TWIN 100 150 Flex Stainless steel 100 mm Incl Ceiling plate 300x300 mm ATWIN 466 100 150 Adapter Flex Stainless stee...

Страница 36: ...g locking band 2x 11 TWG13 100 150 Twin wall balanced ue pipe L 1000 mm Including lock ing band 10 TWG14 100 150 Twin wall balanced ue pipe L 500 mm Including locking band 10 TWG15 100 150 Twin wall b...

Страница 37: ...cluding locking band 15 TWG18 100 150 Twin wall balanced ue el bow 45 Including locking band 14 TWG60 100 150 Twin wall balanced ue el bow 90 Including locking band 14 TWG1786 100 150 Twin wall balanc...

Страница 38: ...ashing and storm collar 17 TW38 150 Roof ashing with a roof pitch of 26 35 With ex alu ashing and storm collar 17 TW54 150 Roof ashing with a roof pitch of 36 45 With ex alu ashing and storm collar 1...

Страница 39: ...m ZU WA891200 Extension pieces for the wall strap ZUWA704 L 200 mm ZU WA891250 Extension pieces for the wall strap ZUWA704 L 250 mm ZUWA706 Extension pieces for the wall strap ZUWA704 L 400 mm WA 50 3...

Страница 40: ...iling plate with adapter FLEX to TWIN GAS 25 ZUWA1618 100 Adapter TWIN GAS to Schaft DE 25 TWG1732 100 150 Chimney at roof ceiling plate with adapter 100 rig id ex to TWIN GAS 33 TWG317 100 150 Concen...

Страница 41: ...th transverse support Type II 500 mm Distance to wall WA 50 150 mm DW393 Wall support with transverse support Type III 750 mm Distance to wall WA 150 250 mm DW407 Wall support with transverse support...

Страница 42: ...Available components for the concentric flue system 4 42 Box Gas Panorama 45 45...

Страница 43: ...Available components for the concentric flue system Box Gas Panorama 45 45 4 43...

Страница 44: ...Y Your Bellfires dealer 001 29 08 2018 347718...

Отзывы: